{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T13:10:36Z","timestamp":1762866636227},"reference-count":20,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2015,9,1]],"date-time":"2015-09-01T00:00:00Z","timestamp":1441065600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","internationaljournalofcardiology.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Cardiology"],"published-print":{"date-parts":[[2015,9]]},"DOI":"10.1016\/j.ijcard.2015.05.139","type":"journal-article","created":{"date-parts":[[2015,5,23]],"date-time":"2015-05-23T08:03:35Z","timestamp":1432368215000},"page":"171-175","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":40,"special_numbering":"C","title":["Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve"],"prefix":"10.1016","volume":"195","author":[{"given":"Jochen","family":"W\u00f6hrle","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Birgid","family":"Gonska","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christoph","family":"Rodewald","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ulrike","family":"Trepte","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sabrina","family":"Koch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominik","family":"Scharnbeck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julia","family":"Seeger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sinisa","family":"Markovic","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wolfgang","family":"Rottbauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ijcard.2015.05.139_bb0005","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","article-title":"Transcatheter versus surgical aortic-valve replacement in high-risk patients","volume":"364","author":"Smith","year":"2011","journal-title":"N. Engl. J. Med."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0010","doi-asserted-by":"crossref","first-page":"1790","DOI":"10.1056\/NEJMoa1400590","article-title":"Transcatheter aortic-valve replacement with a self-expanding prosthesis","volume":"370","author":"Adams","year":"2014","journal-title":"N. Engl. J. Med."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0015","doi-asserted-by":"crossref","first-page":"1686","DOI":"10.1056\/NEJMoa1200384","article-title":"Two-year outcomes after transcatheter or surgical aortic-valve replacement","volume":"366","author":"Kodali","year":"2012","journal-title":"N. Engl. J. Med."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0020","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.4244\/EIJV9I11A216","article-title":"Transfemoral aortic valve replacement with the repositionable Lotus Valve System in high surgical risk patients: the REPRISE I study","volume":"9","author":"Meredith","year":"2014","journal-title":"EuroIntervention"},{"key":"10.1016\/j.ijcard.2015.05.139_bb0025","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1016\/j.jacc.2014.05.067","article-title":"Transcatheter aortic valve replacement for severe symptomatic aortic stenosis using a repositionable valve system: 30-day primary endpoint results from the REPRISE II study","volume":"64","author":"Meredith Am","year":"2014","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0030","doi-asserted-by":"crossref","first-page":"Q70","DOI":"10.4244\/EIJV8SQA12","article-title":"Boston Scientific Lotus Valve","volume":"8","author":"Meredith","year":"2012","journal-title":"EuroIntervention"},{"key":"10.1016\/j.ijcard.2015.05.139_bb0035","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.jcmg.2007.12.006","article-title":"Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement","volume":"1","author":"Tops","year":"2008","journal-title":"J. Am. Coll. Cardiol. Img."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0040","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1016\/j.jacc.2011.11.048","article-title":"Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation","volume":"59","author":"Sinning","year":"2012","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0045","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/0002-9149(64)90027-X","article-title":"Left retrograde cardioangiography in acquired cardiac disease: technic, indications and interpretations in 700 cases","volume":"14","author":"Sellers","year":"1964","journal-title":"Am. J. Cardiol."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0050","doi-asserted-by":"crossref","first-page":"1503","DOI":"10.1001\/jama.2014.3316","article-title":"Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial","volume":"311","author":"Abdel-Wahab","year":"2014","journal-title":"JAMA"},{"key":"10.1016\/j.ijcard.2015.05.139_bb0055","doi-asserted-by":"crossref","first-page":"1438","DOI":"10.1016\/j.jacc.2012.09.001","article-title":"Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document","volume":"60","author":"Kappetein","year":"2012","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0060","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1093\/eurheartj\/ehq406","article-title":"Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium","volume":"32","author":"Leon","year":"2011","journal-title":"Eur. Heart J."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0065","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/j.echo.2009.07.013","article-title":"Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound","volume":"22","author":"Zoghbi","year":"2009","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0070","doi-asserted-by":"crossref","first-page":"1939","DOI":"10.1136\/heartjnl-2013-305390","article-title":"between paravalvar aortic regurgitation and outcome after TAVI.","volume":"100","author":"Dworakowski","year":"2014","journal-title":"Heart"},{"key":"10.1016\/j.ijcard.2015.05.139_bb0075","doi-asserted-by":"crossref","first-page":"1585","DOI":"10.1016\/j.jacc.2013.01.047","article-title":"Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement","volume":"61","author":"Athappan","year":"2013","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0080","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1093\/eurheartj\/ehu384","article-title":"Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes","volume":"36","author":"Kodali","year":"2015","journal-title":"Eur. Heart J."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0085","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/j.jcin.2014.02.013","article-title":"Outcomes with post-dilation following transcatheter aortic valve replacement: the PARTNER I trial (Placement of Aortic Transcatheter Valve)","volume":"7","author":"Hahn","year":"2014","journal-title":"J. Am. Coll. Cardiol. Intv."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0090","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1161\/CIRCINTERVENTIONS.112.971614","article-title":"Efficacy and safety of postdilation to reduce paravalvular regurgitation during balloon-expandable transcatheter aortic valve replacement","volume":"6","author":"Daneault","year":"2013","journal-title":"Circ. Cardiovasc. Interv."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0095","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.jacc.2014.04.033","article-title":"Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis","volume":"64","author":"Siontis","year":"2014","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ijcard.2015.05.139_bb0100","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1161\/CIRCULATIONAHA.113.005479","article-title":"Permanent pacemaker implantation after transcatheter aortic valve implantation: impact on late clinical outcomes and left ventricular function","volume":"129","author":"Urena","year":"2014","journal-title":"Circulation"}],"container-title":["International Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167527315012024?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167527315012024?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,22]],"date-time":"2018-09-22T10:29:11Z","timestamp":1537612151000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0167527315012024"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,9]]},"references-count":20,"alternative-id":["S0167527315012024"],"URL":"https:\/\/doi.org\/10.1016\/j.ijcard.2015.05.139","relation":{},"ISSN":["0167-5273"],"issn-type":[{"value":"0167-5273","type":"print"}],"subject":[],"published":{"date-parts":[[2015,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve","name":"articletitle","label":"Article Title"},{"value":"International Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ijcard.2015.05.139","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Elsevier Ireland Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}