{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T18:24:13Z","timestamp":1792607053803,"version":"4.5.0"},"reference-count":46,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2016,7,1]],"date-time":"2016-07-01T00:00:00Z","timestamp":1467331200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","internationaljournalofcardiology.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Cardiology"],"published-print":{"date-parts":[[2016,7]]},"DOI":"10.1016\/j.ijcard.2016.04.011","type":"journal-article","created":{"date-parts":[[2016,4,9]],"date-time":"2016-04-09T19:57:14Z","timestamp":1460231834000},"page":"454-460","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":26,"special_numbering":"C","title":["Added value of cardiac computed tomography for evaluation of mechanical aortic valve: Emphasis on evaluation of pannus with surgical findings as standard reference"],"prefix":"10.1016","volume":"214","author":[{"given":"Young Joo","family":"Suh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sak","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Jin","family":"Im","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9221-8116","authenticated-orcid":false,"given":"Suyon","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoo Jin","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hye-Jeong","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin","family":"Hur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byoung Wook","family":"Choi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byung-Chul","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chi Young","family":"Shim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geu-Ru","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young Jin","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ijcard.2016.04.011_bb0005","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1007\/s10047-006-0334-3","article-title":"Prevalence of pannus formation after aortic valve replacement: clinical aspects and surgical management","volume":"9","author":"Sakamoto","year":"2006","journal-title":"J Artif Organs"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0010","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1016\/j.ijcard.2014.08.053","article-title":"The prevalence of aortic stenosis in the elderly in Iceland and predictions for the coming decades: the AGES-Reykjavik study","volume":"176","author":"Danielsen","year":"2014","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0015","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ijcard.2015.02.013","article-title":"Forme fruste or \u2018Incomplete\u2019 bicuspid aortic valves with very small raphes: the prevalence of bicuspid valve and its significance may be underestimated","volume":"184","author":"Sperling","year":"2015","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0020","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1038\/nrcardio.2011.71","article-title":"Diagnostic evaluation of left-sided prosthetic heart valve dysfunction","volume":"8","author":"Habets","year":"2011","journal-title":"Nat Rev Cardiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0025","doi-asserted-by":"crossref","first-page":"e521","DOI":"10.1161\/CIR.0000000000000031","article-title":"2014 AHA\/acc guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines","volume":"129","author":"Nishimura","year":"2014","journal-title":"Circulation"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0030","doi-asserted-by":"crossref","first-page":"2451","DOI":"10.1093\/eurheartj\/ehs109","article-title":"Guidelines on the management of valvular heart disease (version 2012)","volume":"33","author":"Joint Task Force on the Management of Valvular Heart Disease of the European Society of C","year":"2012","journal-title":"Eur Heart J"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0035","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/j.echo.2009.07.013","volume":"22","author":"Zoghbi","year":"2009","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0040","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1111\/echo.12327","article-title":"Real time three-dimensional transesophageal echocardiography: a novel approach for the assessment of prosthetic heart valves","volume":"31","author":"Anwar","year":"2014","journal-title":"Echocardiography"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0045","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1016\/S0735-1097(00)01113-X","article-title":"Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: trends in diagnostic testing and comparison with surgical findings","volume":"37","author":"Girard","year":"2001","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0050","doi-asserted-by":"crossref","first-page":"157","DOI":"10.4070\/kcj.2009.39.4.157","article-title":"The measurement of opening angle and orifice area of a bileaflet mechanical valve using multidetector computed tomography","volume":"39","author":"Lee","year":"2009","journal-title":"Korean Circ J"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0055","doi-asserted-by":"crossref","first-page":"W389","DOI":"10.2214\/AJR.08.2178","article-title":"Evaluation of mechanical heart valve size and function with ECG-gated 64-MDCT","volume":"193","author":"LaBounty","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0060","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1007\/s00330-008-1232-2","article-title":"Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard","volume":"19","author":"Tsai","year":"2009","journal-title":"Eur Radiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0065","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/S0003-4975(03)01531-5","article-title":"Usefulness of a multidetector-row computed tomography scanner for detecting pannus formation","volume":"77","author":"Teshima","year":"2004","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0070","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1253\/circj.CJ-12-0290","article-title":"Evaluation of prosthetic valve obstruction on electrocardiographically gated multidetector-row computed tomography\u2014identification of subprosthetic pannus in the aortic position","volume":"77","author":"Ueda","year":"2013","journal-title":"Circ J"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0075","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1016\/S0003-4975(02)04772-0","article-title":"Detection of pannus by multidetector-row computed tomography","volume":"75","author":"Teshima","year":"2003","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0080","first-page":"665","article-title":"Usefulness of computed tomography scanning in the diagnosis of aortic prosthetic valve pannus","volume":"19","author":"Toledano","year":"2010","journal-title":"J Heart Valve Dis"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0085","doi-asserted-by":"crossref","first-page":"174","DOI":"10.14797\/mdcj-9-3-174","article-title":"Utility of cardiac computed tomography for assessment of prosthetic aortic valve dysfunction with pannus formation","volume":"9","author":"Kassi","year":"2013","journal-title":"Methodist Debakey Cardiovasc J"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0090","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1016\/j.amjcard.2009.05.061","article-title":"Comparison of multidetector-row computed tomography to echocardiography and fluoroscopy for evaluation of patients with mechanical prosthetic valve obstruction","volume":"104","author":"Symersky","year":"2009","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0095","article-title":"Subprosthetic pannus after aortic valve replacement surgery: cardiac CT findings and clinical features","volume":"142400","author":"Han","year":"2015","journal-title":"Radiology"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0100","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1007\/s10554-015-0683-1","article-title":"Utility of cardiac computed tomography for evaluation of pannus in mechanical aortic valve","volume":"31","author":"Suh","year":"2015","journal-title":"Int J Cardiovasc Imaging"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0105","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1016\/0002-8703(91)90472-T","article-title":"Pathologic and angiographic correlations of transesophageal echocardiography in prosthetic heart valve dysfunction","volume":"122","author":"Chaudhry","year":"1991","journal-title":"Am Heart J"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0110","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1093\/eurheartj\/14.4.447","article-title":"Diagnosis of prosthetic heart valve thrombosis. the respective values of transthoracic and transoesophageal doppler echocardiography","volume":"14","author":"Habib","year":"1993","journal-title":"Eur Heart J"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0115","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/S0002-9149(99)00607-4","article-title":"Role of cine-fluoroscopy, transthoracic, and transesophageal echocardiography in patients with suspected prosthetic heart valve thrombosis","volume":"85","author":"Montorsi","year":"2000","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0120","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1016\/S0735-1097(98)00385-4","article-title":"Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: an evaluation of clinical, transthoracic and transesophageal echocardiographic parameters","volume":"32","author":"Barbetseas","year":"1998","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0125","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1007\/BF00311926","article-title":"Obstruction of mechanical valve prostheses: clinical diagnosis and surgical or nonsurgical treatment","volume":"26","author":"Aoyagi","year":"1996","journal-title":"Surg Today"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0130","doi-asserted-by":"crossref","first-page":"2407","DOI":"10.1007\/s00330-012-2491-5","article-title":"ECG-gated computed tomography: a new role for patients with suspected aortic prosthetic valve endocarditis","volume":"22","author":"Fagman","year":"2012","journal-title":"Eur Radiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0135","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.3348\/kjr.2015.16.5.1012","article-title":"Measurement of opening and closing angles of aortic valve prostheses in vivo using dual-source computed tomography: comparison with those of manufacturers' in 10 different types","volume":"16","author":"Suh","year":"2015","journal-title":"Korean J Radiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0140","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1093\/ehjci\/jet127","article-title":"Differentiation of thrombus from pannus as the cause of acquired mechanical prosthetic heart valve obstruction by non-invasive imaging: a review of the literature","volume":"15","author":"Tanis","year":"2014","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0145","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/S0733-8651(03)00026-2","article-title":"Imaging techniques for diagnosis of infective endocarditis","volume":"21","author":"Sachdev","year":"2003","journal-title":"Cardiol Clin"},{"issue":"Suppl. 1","key":"10.1016\/j.ijcard.2016.04.011_bb0150","first-page":"Ii79","article-title":"Prosthetic mitral valve thrombosis: can fluoroscopy predict the efficacy of thrombolytic treatment?","volume":"108","author":"Montorsi","year":"2003","journal-title":"Circulation"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0155","doi-asserted-by":"crossref","first-page":"1865","DOI":"10.1016\/j.jacc.2009.02.026","article-title":"Outcome after aortic valve replacement for low-flow\/low-gradient aortic stenosis without contractile reserve on dobutamine stress echocardiography","volume":"53","author":"Tribouilloy","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0160","doi-asserted-by":"crossref","first-page":"e739","DOI":"10.1161\/CIRCULATIONAHA.111.075853","article-title":"Low-flow\/low-gradient aortic stenosis","volume":"124","author":"Awtry","year":"2011","journal-title":"Circulation"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0165","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1111\/echo.12602","article-title":"The additional value of three-dimensional transesophageal echocardiography in complex aortic prosthetic heart valve endocarditis","volume":"32","author":"Tanis","year":"2015","journal-title":"Echocardiography"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0170","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.ijcard.2015.06.052","article-title":"Real-time three-dimensional echocardiography: never before clinical efficacy looked so picturesque","volume":"198","author":"Aggeli","year":"2015","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0175","doi-asserted-by":"crossref","first-page":"1623","DOI":"10.1007\/s00330-014-3551-9","article-title":"Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?","volume":"25","author":"Tanis","year":"2015","journal-title":"Eur Radiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0180","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1097\/00004728-199107000-00005","article-title":"CT and MR evaluation of pericardial and retrosternal adhesions after cardiac surgery","volume":"15","author":"Duvernoy","year":"1991","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0185","doi-asserted-by":"crossref","first-page":"2944","DOI":"10.1007\/s00330-013-2944-5","article-title":"Detection of left atrial thrombus in patients with mitral stenosis and atrial fibrillation: retrospective comparison of two-phase computed tomography, transoesophageal echocardiography and surgical findings","volume":"23","author":"Choi","year":"2013","journal-title":"Eur Radiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0190","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1016\/j.ijcard.2014.08.035","article-title":"CT coronary angiography in the investigation of chest pain\u2014beyond coronary artery atherosclerosis; a pictorial review","volume":"176","author":"Kanaganayagam","year":"2014","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0195","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.ijcard.2014.01.008","article-title":"Multidetector computed tomography of congenital aortic abnormalities","volume":"172","author":"Lindsay","year":"2014","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0200","first-page":"799","article-title":"Aortic valve stenosis: non-invasive preoperative evaluation using 64-slice CT angiography","volume":"56","author":"Ciolina","year":"2015","journal-title":"J Card Surg"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0205","doi-asserted-by":"crossref","first-page":"1893","DOI":"10.1148\/rg.327125702","article-title":"Multidetector CT angiography in evaluation of prosthetic heart valve dysfunction","volume":"32","author":"Habets","year":"2012","journal-title":"Radiographics"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0210","doi-asserted-by":"crossref","first-page":"26","DOI":"10.2214\/AJR.07.2951","article-title":"The role of ECG-gated MDCT in the evaluation of aortic and mitral mechanical valves: initial experience","volume":"191","author":"Konen","year":"2008","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0215","doi-asserted-by":"crossref","first-page":"1518","DOI":"10.1093\/eurheartj\/ehs003","article-title":"The impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years","volume":"33","author":"Head","year":"2012","journal-title":"Eur Heart J"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0220","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.ijcard.2012.04.084","article-title":"A meta-analysis of effects of prosthesis-patient mismatch after aortic valve replacement on late mortality","volume":"159","author":"Takagi","year":"2012","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0225","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1016\/j.athoracsur.2007.12.031","article-title":"Long-term results of aortic valve replacement with a small St. Jude medical valve in Japanese patients","volume":"85","author":"Yoshikawa","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.ijcard.2016.04.011_bb0230","first-page":"56","article-title":"Impact of patient-prosthesis mismatch in the aortic position: twenty-year experience with Korean patients","volume":"22","author":"Jeong","year":"2013","journal-title":"J Heart Valve Dis"}],"container-title":["International Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167527316306866?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167527316306866?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,13]],"date-time":"2018-09-13T09:57:23Z","timestamp":1536832643000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0167527316306866"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7]]},"references-count":46,"alternative-id":["S0167527316306866"],"URL":"https:\/\/doi.org\/10.1016\/j.ijcard.2016.04.011","relation":{},"ISSN":["0167-5273"],"issn-type":[{"value":"0167-5273","type":"print"}],"subject":[],"published":{"date-parts":[[2016,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Added value of cardiac computed tomography for evaluation of mechanical aortic valve: Emphasis on evaluation of pannus with surgical findings as standard reference","name":"articletitle","label":"Article Title"},{"value":"International Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ijcard.2016.04.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Elsevier Ireland Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}