{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T06:52:03Z","timestamp":1787813523938,"version":"build-2784847793"},"reference-count":41,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:00:00Z","timestamp":1535760000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","internationaljournalofcardiology.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Cardiology"],"published-print":{"date-parts":[[2018,9]]},"DOI":"10.1016\/j.ijcard.2018.01.018","type":"journal-article","created":{"date-parts":[[2018,6,14]],"date-time":"2018-06-14T01:55:48Z","timestamp":1528941348000},"page":"56-60","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":23,"special_numbering":"C","title":["Aortic valve anatomy and outcomes after transcatheter aortic valve implantation in bicuspid aortic valves"],"prefix":"10.1016","volume":"266","author":[{"given":"C.","family":"De Biase","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Mastrokostopoulos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Philippart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.M.","family":"Desroche","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Blanco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Rehal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N.","family":"Dumonteil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Tchetche","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"19","key":"10.1016\/j.ijcard.2018.01.018_bb0005","doi-asserted-by":"crossref","first-page":"2451","DOI":"10.1093\/eurheartj\/ehs109","article-title":"Guidelines on the management of valvular heart disease (version 2012)","volume":"33","author":"Vahanian","year":"2012","journal-title":"Eur. Heart J."},{"key":"10.1016\/j.ijcard.2018.01.018_bb0010","first-page":"2017","article-title":"AHA\/ACC Focused Update of the 2014 AHA\/ACC Guideline for the Management of Patients With Valvular Heart Disease: a report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines","author":"Nishimura","year":"2017","journal-title":"J. of the American College of Cardiology"},{"issue":"23","key":"10.1016\/j.ijcard.2018.01.018_bb0015","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","article-title":"Transcatheter versus surgical aortic-valve replacement in high-risk patients","volume":"364","author":"Smith","year":"2011","journal-title":"N. Engl. J. Med."},{"issue":"17","key":"10.1016\/j.ijcard.2018.01.018_bb0020","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1056\/NEJMoa1514616","article-title":"Transcatheter or surgical aortic-valve replacement in intermediate-risk patients","volume":"374","author":"Leon","year":"2016","journal-title":"N. Engl. J. Med."},{"issue":"14","key":"10.1016\/j.ijcard.2018.01.018_bb0025","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1056\/NEJMoa1700456","article-title":"Surgical or transcatheter aortic-valve replacement in intermediate-risk patients","volume":"376","author":"Reardon","year":"2017","journal-title":"N. Engl. J. Med."},{"issue":"25","key":"10.1016\/j.ijcard.2018.01.018_bb0030","doi-asserted-by":"crossref","first-page":"2789","DOI":"10.1016\/j.jacc.2009.12.068","article-title":"Bicuspid aortic valve disease","volume":"55","author":"Siu","year":"2010","journal-title":"J. Am. Coll. Cardiol."},{"issue":"1","key":"10.1016\/j.ijcard.2018.01.018_bb0035","doi-asserted-by":"crossref","first-page":"14","DOI":"10.4065\/74.1.14","article-title":"Congenitally bicuspid aortic valves: a surgical pathology study of 542 cases (1991 through 1996) and a literature review of 2,715 additional cases","volume":"74","author":"Sabet","year":"1999","journal-title":"Mayo Clin. Proc."},{"issue":"2","key":"10.1016\/j.ijcard.2018.01.018_bb0040","doi-asserted-by":"crossref","first-page":"E88","DOI":"10.1002\/ccd.25948","article-title":"Aortic annulus and root characteristics in severe aortic stenosis due to bicuspid aortic valve and tricuspid aortic valves: implications for transcatheter aortic valve therapies","volume":"86","author":"Philip","year":"2015","journal-title":"Catheterization and Cardiovascular Interventions: Official Journal of the Society for Cardiac Angiography & Interventions."},{"issue":"3","key":"10.1016\/j.ijcard.2018.01.018_bb0045","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1016\/j.athoracsur.2009.12.022","article-title":"Increased radial force improves stent deployment in tricuspid but not in bicuspid stenotic native aortic valves","volume":"89","author":"Zegdi","year":"2010","journal-title":"Ann. Thorac. Surg."},{"issue":"2","key":"10.1016\/j.ijcard.2018.01.018_bb0050","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1038\/nrcardio.2014.161","article-title":"Transcatheter aortic valve implantation in bicuspid anatomy","volume":"12","author":"Zhao","year":"2015","journal-title":"Nat. Rev. Cardiol."},{"issue":"22","key":"10.1016\/j.ijcard.2018.01.018_bb0055","doi-asserted-by":"crossref","first-page":"2330","DOI":"10.1016\/j.jacc.2014.09.039","article-title":"Transcatheter aortic valve replacement in bicuspid aortic valve disease","volume":"64","author":"Mylotte","year":"2014","journal-title":"J. Am. Coll. Cardiol."},{"issue":"8","key":"10.1016\/j.ijcard.2018.01.018_bb0060","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1016\/j.jcin.2016.01.002","article-title":"Bicuspid aortic valve stenosis: favorable early outcomes with a next-generation transcatheter heart valve in a multicenter study","volume":"9","author":"Perlman","year":"2016","journal-title":"JACC Cardiovascular interventions."},{"key":"10.1016\/j.ijcard.2018.01.018_bb0065","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1016\/j.ijcard.2015.04.066","article-title":"Transcatheter aortic valve implantation in patients with bicuspid aortic valve: a patient level multi-center analysis","volume":"189","author":"Yousef","year":"2015","journal-title":"Int. J. Cardiol."},{"issue":"11","key":"10.1016\/j.ijcard.2018.01.018_bb0070","doi-asserted-by":"crossref","first-page":"1632","DOI":"10.1016\/j.amjcard.2012.01.390","article-title":"Frequency of congenitally bicuspid aortic valves in patients >\/=80\u202fyears of age undergoing aortic valve replacement for aortic stenosis (with or without aortic regurgitation) and implications for transcatheter aortic valve implantation","volume":"109","author":"Roberts","year":"2012","journal-title":"Am. J. Cardiol."},{"issue":"5","key":"10.1016\/j.ijcard.2018.01.018_bb0075","doi-asserted-by":"crossref","first-page":"1226","DOI":"10.1016\/j.jtcvs.2007.01.039","article-title":"A classification system for the bicuspid aortic valve from 304 surgical specimens","volume":"133","author":"Sievers","year":"2007","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"6","key":"10.1016\/j.ijcard.2018.01.018_bb0080","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1093\/ehjci\/jew025","volume":"17","author":"Lancellotti","year":"2016","journal-title":"European Heart Journal Cardiovascular Imaging"},{"issue":"5","key":"10.1016\/j.ijcard.2018.01.018_bb0085","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1016\/j.jtcvs.2005.12.032","article-title":"Prosthesis-patient mismatch and clinical outcomes: the evidence continues to accumulate","volume":"131","author":"Dumesnil","year":"2006","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"8","key":"10.1016\/j.ijcard.2018.01.018_bb0090","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1136\/hrt.2005.067363","article-title":"Prosthesis-patient mismatch: definition, clinical impact, and prevention","volume":"92","author":"Pibarot","year":"2006","journal-title":"Heart"},{"issue":"4","key":"10.1016\/j.ijcard.2018.01.018_bb0095","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1161\/CIRCULATIONAHA.105.587022","article-title":"Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis","volume":"113","author":"Tasca","year":"2006","journal-title":"Circulation"},{"issue":"15","key":"10.1016\/j.ijcard.2018.01.018_bb0100","doi-asserted-by":"crossref","first-page":"1438","DOI":"10.1016\/j.jacc.2012.09.001","article-title":"Updated standardized endpoint definitions for transcatheter aortic valve implantation: the valve academic research consortium-2 consensus document","volume":"60","author":"Kappetein","year":"2012","journal-title":"J. Am. Coll. Cardiol."},{"issue":"12","key":"10.1016\/j.ijcard.2018.01.018_bb0105","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1016\/j.jacc.2014.05.066","article-title":"Impact of aortic valve calcification, as measured by MDCT, on survival in patients with aortic stenosis: results of an international registry study","volume":"64","author":"Clavel","year":"2014","journal-title":"J. Am. Coll. Cardiol."},{"issue":"3","key":"10.1016\/j.ijcard.2018.01.018_bb0110","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1007\/s10554-015-0783-y","article-title":"The significance of aortic valve calcification in patients with bicuspid aortic valve disease","volume":"32","author":"Ren","year":"2016","journal-title":"The International Journal of Cardiovascular Imaging."},{"issue":"6","key":"10.1016\/j.ijcard.2018.01.018_bb0115","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1093\/ehjci\/jex009","article-title":"Relation between calcium burden, echocardiographic stent frame eccentricity and paravalvular leakage after corevalve transcatheter aortic valve implantation","volume":"18","author":"Di Martino","year":"2017","journal-title":"European Heart Journal Cardiovascular Imaging."},{"issue":"4","key":"10.1016\/j.ijcard.2018.01.018_bb0120","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1016\/j.amjcard.2016.10.047","article-title":"Predictors of paravalvular regurgitation after transcatheter aortic valve implantation for aortic stenosis using new-generation balloon-expandable SAPIEN 3","volume":"119","author":"Kaneko","year":"2017","journal-title":"Am. J. Cardiol."},{"issue":"5","key":"10.1016\/j.ijcard.2018.01.018_bb0125","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1002\/ccd.26671","article-title":"Clinical and hemodynamic results after direct transcatheter aortic valve replacement versus pre-implantation balloon aortic valvuloplasty: a case-matched analysis","volume":"90","author":"Ferrera","year":"2017","journal-title":"Catheter Cardiovasc Interv."},{"issue":"10","key":"10.1016\/j.ijcard.2018.01.018_bb0130","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1016\/j.acvd.2016.12.012","article-title":"Baseline characteristics and outcomes after transcatheter aortic-valve implantation in patients with or without previous balloon aortic valvuloplasty: insights from the FRANCE 2 registry","volume":"110","author":"Biere","year":"2017","journal-title":"Arch. Cardiovasc. Dis."},{"issue":"2","key":"10.1016\/j.ijcard.2018.01.018_bb0135","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1016\/j.cjca.2016.09.007","article-title":"Comparison of systematic predilation, selective predilation, and direct transcatheter aortic valve implantation with the SAPIEN S3 valve","volume":"33","author":"Spaziano","year":"2017","journal-title":"The Canadian Journal of Cardiology"},{"issue":"5","key":"10.1016\/j.ijcard.2018.01.018_bb0140","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.jcin.2008.06.010","article-title":"Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size?","volume":"1","author":"Babaliaros","year":"2008","journal-title":"JACC Cardiovascular Interventions"},{"issue":"21","key":"10.1016\/j.ijcard.2018.01.018_bb0145","doi-asserted-by":"crossref","first-page":"2579","DOI":"10.1016\/j.jacc.2017.03.017","article-title":"Outcomes in transcatheter aortic valve replacement for bicuspid versus tricuspid aortic valve stenosis","volume":"69","author":"Yoon","year":"2017","journal-title":"J. Am. Coll. Cardiol."},{"issue":"11","key":"10.1016\/j.ijcard.2018.01.018_bb0150","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1016\/j.jacc.2016.06.041","article-title":"Transcatheter aortic valve replacement with early- and new-generation devices in bicuspid aortic valve stenosis","volume":"68","author":"Yoon","year":"2016","journal-title":"J. Am. Coll. Cardiol."},{"issue":"Y","key":"10.1016\/j.ijcard.2018.01.018_bb0155","doi-asserted-by":"crossref","first-page":"Y42","DOI":"10.4244\/EIJV12SYA10","article-title":"Transcatheter aortic valve implantation in bicuspid aortic valve stenosis","volume":"12","author":"Perlman","year":"2016","journal-title":"EuroIntervention: Journal of EuroPCR in Collaboration With the Working Group on Interventional Cardiology of the European Society of Cardiology."},{"issue":"5","key":"10.1016\/j.ijcard.2018.01.018_bb0160","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.jacc.2013.04.036","article-title":"The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial","volume":"62","author":"Binder","year":"2013","journal-title":"J. Am. Coll. Cardiol."},{"issue":"6","key":"10.1016\/j.ijcard.2018.01.018_bb0165","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1016\/j.jcin.2014.02.010","article-title":"Erroneous measurement of the aortic annular diameter using 2-dimensional echocardiography resulting in inappropriate CoreValve size selection: a retrospective comparison with multislice computed tomography","volume":"7","author":"Mylotte","year":"2014","journal-title":"JACC Cardiovascular Interventions"},{"issue":"11","key":"10.1016\/j.ijcard.2018.01.018_bb0170","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1136\/hrt.2010.217158","article-title":"Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry","volume":"97","author":"Abdel-Wahab","year":"2011","journal-title":"Heart"},{"issue":"7","key":"10.1016\/j.ijcard.2018.01.018_bb0175","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1093\/eurheartj\/ehu384","article-title":"Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes","volume":"36","author":"Kodali","year":"2015","journal-title":"Eur. Heart J."},{"issue":"38","key":"10.1016\/j.ijcard.2018.01.018_bb0180","doi-asserted-by":"crossref","first-page":"2662","DOI":"10.1093\/eurheartj\/ehu267","article-title":"Bicuspid aortic valve stenosis with successful transfemoral transcatheter aortic valve replacement (TAVI) using the Sapien 3 valve","volume":"35","author":"Thilo","year":"2014","journal-title":"Eur. Heart J."},{"issue":"13","key":"10.1016\/j.ijcard.2018.01.018_bb0185","doi-asserted-by":"crossref","first-page":"1727","DOI":"10.1016\/j.jcin.2015.08.011","article-title":"A strategy of underexpansion and ad hoc post-dilation of balloon-expandable transcatheter aortic valves in patients at risk of annular injury: favorable mid-term outcomes","volume":"8","author":"Tan","year":"2015","journal-title":"JACC Cardiovascular interventions."},{"issue":"3","key":"10.1016\/j.ijcard.2018.01.018_bb0190","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1016\/j.jcin.2014.10.014","article-title":"Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the Sapien 3: a comparison with the Sapien XT","volume":"8","author":"Yang","year":"2015","journal-title":"JACC Cardiovascular Interventions"},{"issue":"21","key":"10.1016\/j.ijcard.2018.01.018_bb0195","doi-asserted-by":"crossref","first-page":"2235","DOI":"10.1016\/j.jacc.2014.09.026","article-title":"Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve","volume":"64","author":"Webb","year":"2014","journal-title":"J. Am. Coll. Cardiol."},{"issue":"6","key":"10.1016\/j.ijcard.2018.01.018_bb0200","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1016\/j.amjcard.2012.04.064","article-title":"Feasibility and outcomes of transcatheter aortic valve implantation in high-risk patients with stenotic bicuspid aortic valves","volume":"110","author":"Himbert","year":"2012","journal-title":"Am. J. Cardiol."},{"issue":"2","key":"10.1016\/j.ijcard.2018.01.018_bb0205","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1002\/ccd.25830","article-title":"Comparison of multislice computed tomography findings between bicuspid and tricuspid aortic valves before and after transcatheter aortic valve implantation","volume":"86","author":"Watanabe","year":"2015","journal-title":"Catheterization and Cardiovascular Interventions: Official Journal of the Society for Cardiac Angiography & Interventions."}],"container-title":["International Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167527317344698?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167527317344698?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,2,11]],"date-time":"2019-02-11T23:16:00Z","timestamp":1549926960000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0167527317344698"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9]]},"references-count":41,"alternative-id":["S0167527317344698"],"URL":"https:\/\/doi.org\/10.1016\/j.ijcard.2018.01.018","relation":{},"ISSN":["0167-5273"],"issn-type":[{"value":"0167-5273","type":"print"}],"subject":[],"published":{"date-parts":[[2018,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Aortic valve anatomy and outcomes after transcatheter aortic valve implantation in bicuspid aortic valves","name":"articletitle","label":"Article Title"},{"value":"International Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ijcard.2018.01.018","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}