{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T11:00:34Z","timestamp":1788001234406,"version":"build-2784847793"},"reference-count":23,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","internationaljournalofcardiology.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Cardiology"],"published-print":{"date-parts":[[2019,1]]},"DOI":"10.1016\/j.ijcard.2018.09.010","type":"journal-article","created":{"date-parts":[[2018,9,8]],"date-time":"2018-09-08T16:02:16Z","timestamp":1536422536000},"page":"382-387","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":32,"special_numbering":"C","title":["Diagnostic accuracy of coronary CT angiography performed in 100 consecutive patients with coronary stents using a whole-organ high-definition CT scanner"],"prefix":"10.1016","volume":"274","author":[{"given":"Daniele","family":"Andreini","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianluca","family":"Pontone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saima","family":"Mushtaq","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edoardo","family":"Conte","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Guglielmo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Elisabetta","family":"Mancini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Annoni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Baggiano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Formenti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piero","family":"Montorsi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Magatelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca","family":"Di Odoardo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eleonora","family":"Melotti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marta","family":"Resta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Muscogiuri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cesare","family":"Fiorentini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio L.","family":"Bartorelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mauro","family":"Pepi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ijcard.2018.09.010_bb0005","series-title":"Imaging of Coronary Stents: Past, Present, and Future","author":"Mahnken","year":"2012"},{"key":"10.1016\/j.ijcard.2018.09.010_bb0010","doi-asserted-by":"crossref","first-page":"2567","DOI":"10.1093\/eurheartj\/ehl303","article-title":"Assessment of coronary artery stent restenosis by 64-slice multi-detector computed tomography","volume":"27","author":"Rixe","year":"2006","journal-title":"Eur. Heart J."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0015","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1016\/j.jacc.2006.10.065","article-title":"Diagnostic accuracy of coronary in-stent restenosis using 64-slice computed tomography: comparison with invasive coronary angiography","volume":"49","author":"Ehara","year":"2007","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0020","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1016\/j.amjcard.2009.01.343","article-title":"Comparison of feasibility and diagnostic accuracy of 64-slice multidetector computed tomographic coronary angiography versus invasive coronary angiography versus intravascular ultrasound for evaluation of in-stent restenosis","volume":"103","author":"Andreini","year":"2009","journal-title":"Am. J. Cardiol."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0025","doi-asserted-by":"crossref","first-page":"1430","DOI":"10.1007\/s00330-011-2085-7","article-title":"High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis","volume":"21","author":"Andreini","year":"2011","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0030","doi-asserted-by":"crossref","first-page":"2896","DOI":"10.1007\/s00330-009-1618-9","article-title":"Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience","volume":"19","author":"Leschka","year":"2009","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0035","doi-asserted-by":"crossref","first-page":"1675","DOI":"10.1016\/j.amjcard.2009.02.024","article-title":"Meta-analysis of diagnostic efficacy of 64-slice computed tomography in the evaluation of coronary in-stent restenosis","volume":"103","author":"Kumbhani","year":"2009","journal-title":"Am. J. Cardiol."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0040","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1016\/j.amjcard.2009.10.046","article-title":"Multidetector computed tomography coronary angiography for the assessment of coronary in-stent restenosis","volume":"105","author":"Andreini","year":"2010","journal-title":"Am. J. Cardiol."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0045","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1148\/radiol.12112363","article-title":"Coronary in-stent restenosis: assessment with CT coronary angiography","volume":"265","author":"Andreini","year":"2012","journal-title":"Radiology"},{"key":"10.1016\/j.ijcard.2018.09.010_bb0050","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1007\/s10554-012-0134-1","article-title":"CT coronary angiography: impact of adapted statistical iterative reconstruction (ASIR) on coronary stenosis and plaque composition analysis","volume":"29","author":"Fuchs","year":"2013","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"10.1016\/j.ijcard.2018.09.010_bb0055","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1016\/j.ejrad.2015.02.004","article-title":"High-definition computed tomography for coronary artery stents imaging: initial evaluation of the optimal reconstruction algorithm","volume":"84","author":"Cui","year":"2015","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0060","doi-asserted-by":"crossref","first-page":"1864","DOI":"10.1016\/j.jacc.2010.07.005","article-title":"ACCF\/SCCT\/ACR\/AHA\/ASE\/ASNC\/NASCI\/SCAI\/SCMR 2010 appropriate use criteria for cardiac computed tomography","volume":"56","author":"Taylor","year":"2010","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0065","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1016\/j.clinimag.2014.11.020","article-title":"Heart-rate dependent improvement in image quality and diagnostic accuracy of coronary computed tomographic angiography by novel intracycle motion correction algorithm","volume":"39","author":"Cho","year":"2015","journal-title":"Clin. Imaging"},{"key":"10.1016\/j.ijcard.2018.09.010_bb0070","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1161\/01.CIR.51.4.5","article-title":"A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association","volume":"51","author":"Austen","year":"1975","journal-title":"Circulation"},{"key":"10.1016\/j.ijcard.2018.09.010_bb0075","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1093\/ehjci\/jev033","article-title":"Low-dose CT coronary angiography with a novel IntraCycle motion-correction algorithm in patients with high heart rate or heart rate variability","volume":"16","author":"Andreini","year":"2015","journal-title":"Eur. Heart J. Cardiovasc. Imaging"},{"key":"10.1016\/j.ijcard.2018.09.010_bb0080","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1007\/s12350-010-9218-2","article-title":"Diagnostic accuracy of 64-slice computed tomography coronary angiography for the detection of in-stent restenosis: a meta-analysis","volume":"17","author":"Carrabba","year":"2010","journal-title":"J. Nucl. Cardiol."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0085","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/j.jcct.2014.07.003","article-title":"SCCT guidelines for the interpretation and reporting of coronary CT angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee","volume":"8","author":"Leipsic","year":"2014","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0090","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1007\/s003300050095","article-title":"A workshop on quality criteria for computed tomography held in Arhus, Denmark, November 1998","volume":"10","author":"Geleijns","year":"2000","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0095","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2174\/157340309787048059","article-title":"Patient radiation doses in interventional cardiology procedures","volume":"5","author":"Pantos","year":"2009","journal-title":"Curr. Cardiol. Rev."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0100","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1007\/s00330-015-3793-1","article-title":"Impact of an intra-cycle motion correction algorithm on overall evaluability and diagnostic accuracy of computed tomography coronary angiography","volume":"26","author":"Pontone","year":"2016","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0105","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1148\/radiol.13121224","article-title":"Diagnostic accuracy and radiation dose of CT coronary angiography in atrial fibrillation: systematic review and meta-analysis","volume":"267","author":"Vorre","year":"2013","journal-title":"Radiology"},{"key":"10.1016\/j.ijcard.2018.09.010_bb0110","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1007\/s00330-012-2663-3","article-title":"Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols","volume":"23","author":"Neefjes","year":"2013","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.ijcard.2018.09.010_bb0115","first-page":"s49.14","article-title":"Image quality and radiation exposure in atrial fibrillation patients using dual source computed tomography: customized high pitch versus retrospective ECG gated protocol","volume":"6","author":"Prazeres","year":"2012","journal-title":"J. Cardiovasc. Comput. Tomogr."}],"container-title":["International Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167527318336660?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0167527318336660?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,1,5]],"date-time":"2019-01-05T02:14:28Z","timestamp":1546654468000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0167527318336660"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1]]},"references-count":23,"alternative-id":["S0167527318336660"],"URL":"https:\/\/doi.org\/10.1016\/j.ijcard.2018.09.010","relation":{},"ISSN":["0167-5273"],"issn-type":[{"value":"0167-5273","type":"print"}],"subject":[],"published":{"date-parts":[[2019,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Diagnostic accuracy of coronary CT angiography performed in 100 consecutive patients with coronary stents using a whole-organ high-definition CT scanner","name":"articletitle","label":"Article Title"},{"value":"International Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ijcard.2018.09.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Published by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}