{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T05:37:41Z","timestamp":1740116261714,"version":"3.37.3"},"reference-count":25,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2013,7,21]],"date-time":"2013-07-21T00:00:00Z","timestamp":1374364800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2015,9,1]],"date-time":"2015-09-01T00:00:00Z","timestamp":1441065600000},"content-version":"tdm","delay-in-days":772,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["ijgo.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Intl J Gynecology &amp; Obste"],"published-print":{"date-parts":[[2013,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objective<\/jats:title><jats:p>To compare accuracy between 3D and 2D ultrasonography for predicting lethal pulmonary hypoplasia (LPH) among high\u2010risk fetuses.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>In a cross\u2010sectional prospective study at a fetal medicine referral center in Brazil, bilateral fetal lung scans were evaluated for 54 fetuses with suspected LPH between May 2008 and June 2011. Measurements for predicting LPH were ultrasonographic fetal lung volume\/estimated fetal weight ratio (US\u2010FLW), observed\/expected thoracic circumference (o\/e\u2010TC), observed\/expected thoracic circumference\/abdominal circumference (o\/e\u2010TC\/AC), observed\/expected thoracic area\/heart area (o\/e\u2010TA\/HA), observed\/expected amniotic fluid index (o\/e\u2010AFI), and observed\/expected total fetal lung volume (o\/e\u2010Tot\u2010FLV). To evaluate accuracy in predicting LPH, receiver operating characteristic (ROC) curves were calculated, and areas under the curves (AUCs) were compared. The intraclass correlation coefficient (ICC) was used to assess 3D lung volume reproducibility.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Data were compared for 47 newborns, of whom 34 had LPH (perinatal mortality 74.5%). The AUCs for predicting LPH were 0.93, 0.69, 0.55, 0.46, 0.71, and 0.86 for US\u2010FLW, o\/e\u2010TC, o\/e\u2010TC\/AC, o\/e\u2010TA\/HA, o\/e\u2013AFI, and o\/e\u2010Tot\u2013FLV, respectively. No significant intraobserver difference was observed in measurements of the right (ICC, 0.973; <jats:italic>P<\/jats:italic> &lt; 0.0001) or left (ICC, 0.950; <jats:italic>P<\/jats:italic> &lt; 0.0001) lung volumes.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Among high\u2010risk fetuses, US\u2010FLW by 2D\/3D and o\/e\u2010Tot\u2010FLV by 3D ultrasonography were more accurate than 2D parameters for predicting LPH.<\/jats:p><\/jats:sec>","DOI":"10.1016\/j.ijgo.2013.05.004","type":"journal-article","created":{"date-parts":[[2013,7,21]],"date-time":"2013-07-21T00:15:21Z","timestamp":1374365721000},"page":"42-45","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"title":["Prediction of lethal pulmonary hypoplasia among high\u2010risk fetuses via 2D and 3D ultrasonography"],"prefix":"10.1002","volume":"123","author":[{"given":"Guilherme","family":"de Castro Rezende","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alamanda Kfoury","family":"Pereira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edward","family":"Araujo J\u00fanior","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zilma Silveira Nogueira","family":"Reis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonio Carlos","family":"Vieira Cabral","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2013,7,21]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0029-7844(95)00195-W"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.109.2.250"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1002\/uog.2672"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/pd.1646"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajog.2007.06.005"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00404-008-0908-9"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/pd.2564"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/uog.1799"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/uog.2717"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/uog.6255"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/uog.2670"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/uog.3853"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9378(85)90298-4"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9378(89)90363-3"},{"issue":"7","key":"e_1_2_6_16_2","first-page":"540","article-title":"Amniotic fluid volume assessment with the four\u2010quadrant technique at 36\u201342 weeks' gestation","volume":"32","author":"Phelan J.P.","year":"1987","journal-title":"J Reprod Med"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9378(90)90009-V"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/uog.39"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.3078"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/uog.5167"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1002\/uog.2624"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1002\/uog.10095"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9378(96)70165-5"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-0528.2010.02841.x"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.3109\/14767050903121415"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1447-0756.2009.001060.x"}],"container-title":["International Journal of Gynecology &amp; Obstetrics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/api.elsevier.com\/content\/article\/PII:S0020729213003238?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/api.elsevier.com\/content\/article\/PII:S0020729213003238?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1016%2Fj.ijgo.2013.05.004","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1016%2Fj.ijgo.2013.05.004","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.ijgo.2013.05.004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T12:30:42Z","timestamp":1696336242000},"score":1,"resource":{"primary":{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/10.1016\/j.ijgo.2013.05.004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,7,21]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,10]]}},"alternative-id":["10.1016\/j.ijgo.2013.05.004"],"URL":"https:\/\/doi.org\/10.1016\/j.ijgo.2013.05.004","archive":["Portico"],"relation":{},"ISSN":["0020-7292","1879-3479"],"issn-type":[{"type":"print","value":"0020-7292"},{"type":"electronic","value":"1879-3479"}],"subject":[],"published":{"date-parts":[[2013,7,21]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Prediction of lethal pulmonary hypoplasia among high-risk fetuses via 2D and 3D ultrasonography","name":"articletitle","label":"Article Title"},{"value":"International Journal of Gynecology & Obstetrics","name":"journaltitle","label":"Journal Title"},{"value":"http:\/\/dx.doi.org\/10.1016\/j.ijgo.2013.05.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}