{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T05:47:03Z","timestamp":1771998423512,"version":"3.50.1"},"reference-count":38,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2017,4,1]],"date-time":"2017-04-01T00:00:00Z","timestamp":1491004800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,4,1]],"date-time":"2017-04-01T00:00:00Z","timestamp":1491004800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Hygiene and Environmental Health"],"published-print":{"date-parts":[[2017,4]]},"DOI":"10.1016\/j.ijheh.2016.12.001","type":"journal-article","created":{"date-parts":[[2016,12,2]],"date-time":"2016-12-02T17:15:55Z","timestamp":1480698955000},"page":"401-406","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":40,"special_numbering":"PB","title":["Occurrence of Legionella in UK household showers"],"prefix":"10.1016","volume":"220","author":[{"given":"Samuel","family":"Collins","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Stevenson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Allan","family":"Bennett","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jimmy","family":"Walker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ijheh.2016.12.001_bib0005","doi-asserted-by":"crossref","first-page":"2360","DOI":"10.1128\/aem.57.8.2360-2367.1991","article-title":"Risk factors for contamination of domestic hot water systems by legionellae","volume":"57","author":"Alary","year":"1991","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0010","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1128\/jb.76.5.471-484.1958","article-title":"New sampler for the collection, sizing, and enumeration of viable airborne particles","volume":"76","author":"Andersen","year":"1958","journal-title":"J. Bacteriol."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0015","series-title":"Legionella and the Prevention of Legionellosis","author":"Bartram","year":"2007"},{"key":"10.1016\/j.ijheh.2016.12.001_bib0020","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1136\/jech.2007.063784","article-title":"Legionella bacteria in shower aerosols increase the risk of Pontiac fever among older people in retirement homes","volume":"62","author":"Bauer","year":"2008","journal-title":"J. Epidemiol. Community Health"},{"key":"10.1016\/j.ijheh.2016.12.001_bib0025","doi-asserted-by":"crossref","first-page":"1763","DOI":"10.1017\/S0950268813002483","article-title":"Barrow-in-Furness: a large community legionellosis outbreak in the UK","volume":"142","author":"Bennett","year":"2014","journal-title":"Epidemiol. Infect."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0030","doi-asserted-by":"crossref","first-page":"457","DOI":"10.3201\/eid1003.020707","article-title":"Legionella infection risk from domestic hot water","volume":"10","author":"Borella","year":"2004","journal-title":"Emerg. Infect. Dis."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0035","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1177\/0898264316656513","article-title":"International perspectives on summary measures of population health in an aging world","volume":"28","author":"Chan","year":"2016","journal-title":"J. Aging Health"},{"key":"10.1016\/j.ijheh.2016.12.001_bib0040","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.jaerosci.2012.02.003","article-title":"Evaluation of sampling techniques for detection and quantification of ariborne legionellae at biological aeration basins and shower rooms","volume":"48","author":"Chang","year":"2012","journal-title":"J. Aerosol Sci."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0045","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.1111\/jam.12911","article-title":"Real-time PCR to supplement gold-standard culture-based detection of Legionella in environmental samples","volume":"119","author":"Collins","year":"2015","journal-title":"J. Appl. Microbiol."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0050","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1039\/B610737K","article-title":"Detection of airborne Legionella while showering using liquid impingement and fluorescent in situ hybridization (FISH)","volume":"9","author":"Deloge-Abarkan","year":"2007","journal-title":"J. Environ. Monit."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0055","doi-asserted-by":"crossref","first-page":"37","DOI":"10.3201\/eid0801.010176","article-title":"A large outbreak of Legionnaires' disease at a flower show, the Netherlands, 1999","volume":"8","author":"Den Boer","year":"2002","journal-title":"Emerg. Infect. Dis."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0060","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1017\/S0022172400064901","article-title":"Legionella pneumophila in aerosols from shower baths","volume":"93","author":"Dennis","year":"1984","journal-title":"J. Hyg. (Lond.)"},{"key":"10.1016\/j.ijheh.2016.12.001_bib0065","doi-asserted-by":"crossref","first-page":"4817","DOI":"10.1128\/AEM.02899-07","article-title":"A PCR-based method for monitoring Legionella pneumophila in water samples detects viable but noncultivable legionellae that can recover their cultivability","volume":"74","author":"Dusserre","year":"2008","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0070","series-title":"Legionnaires' Disease in Europe, 2014","author":"European Centre for Disease Control and Prevention","year":"2016"},{"key":"10.1016\/j.ijheh.2016.12.001_bib0075","doi-asserted-by":"crossref","first-page":"16393","DOI":"10.1073\/pnas.0908446106","article-title":"Opportunistic pathogens enriched in showerhead biofilms","volume":"106","author":"Feazel","year":"2009","journal-title":"Proc. Natl. Acad. Sci. U. S. A."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0080","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1128\/CMR.15.3.506-526.2002","article-title":"Legionella and Legionnaires' disease: 25 years of investigation","volume":"15","author":"Fields","year":"2002","journal-title":"Clin. Microbiol. Rev."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0085","doi-asserted-by":"crossref","first-page":"2047","DOI":"10.1128\/JCM.43.5.2047-2052.2005","article-title":"Consensus sequence-based scheme for epidemiological typing of clinical and environmental isolates of Legionella pneumophila","volume":"43","author":"Gaia","year":"2005","journal-title":"J. Clin. Microbiol."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0090","series-title":"Explaining Daily Showering: A Discussion of Policy and Practice","author":"Hand","year":"2003"},{"key":"10.1016\/j.ijheh.2016.12.001_bib0095","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.watres.2014.02.013","article-title":"Assessment of relative potential for Legionella species or surrogates inhalation exposure from common water uses","volume":"56","author":"Hines","year":"2014","journal-title":"Water Res."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0100","doi-asserted-by":"crossref","first-page":"2801","DOI":"10.1128\/AEM.72.4.2801-2808.2006","article-title":"Quantitative real-time Legionella PCR for environmental water samples: data interpretation","volume":"72","author":"Joly","year":"2006","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0105","doi-asserted-by":"crossref","first-page":"2764","DOI":"10.1128\/jcm.31.10.2764-2768.1993","article-title":"Growth of 28 Legionella species on selective culture media: a comparative study","volume":"31","author":"Lee","year":"1993","journal-title":"J. Clin. Microbiol."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0110","first-page":"653","article-title":"[Fatal travel-associated legionella infection caused by shower aerosols in a German hotel]","volume":"55","author":"Muhlenberg","year":"1993","journal-title":"Gesundheitswesen"},{"key":"10.1016\/j.ijheh.2016.12.001_bib0115","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.jhin.2007.04.020","article-title":"Disconnecting central hot water and using electric showers to avoid colonization of the water system by Legionella pneumophila: an 11-year study","volume":"66","author":"Oliveira","year":"2007","journal-title":"J. Hosp. Infect."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0120","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1016\/S1473-3099(14)70713-3","article-title":"Epidemiology and clinical management of Legionnaires' disease","volume":"14","author":"Phin","year":"2014","journal-title":"Lancet Infect. Dis."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0125","unstructured":"Public Health England, 2016. http:\/\/www.hpa-bioinformatics.org.uk\/cgi-bin\/legionella\/mip\/mip_id.cgi. Accessed November 8 2016."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0130","series-title":"The Investigation of Household Water Systems in Cases of Legionnaires' Disease \u2212 Guidance for Health Protection Teams","author":"Public Health England","year":"2016"},{"key":"10.1016\/j.ijheh.2016.12.001_bib0135","unstructured":"Public Health England, 2016. www.hpa-bioinformatics.org.uk\/cgi-bin\/legionella\/sbt\/seq_assemble_legionella1.cgi. Accessed November 8 2016."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0140","doi-asserted-by":"crossref","first-page":"1560","DOI":"10.1128\/JCM.36.6.1560-1567.1998","article-title":"Sequence-based classification scheme for the genus Legionella targeting the mip gene","volume":"36","author":"Ratcliff","year":"1998","journal-title":"J. Clin. Microbiol."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0145","doi-asserted-by":"crossref","first-page":"1965","DOI":"10.1128\/JCM.00261-07","article-title":"Addition of neuA, the gene encoding N-acylneuraminate cytidylyl transferase, increases the discriminatory ability of the consensus sequence-based scheme for typing Legionella pneumophila serogroup 1 strains","volume":"45","author":"Ratzow","year":"2007","journal-title":"J. Clin. Microbiol."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0150","article-title":"The risks of Legionella in water systems in homes, Healthy Buildings International","author":"Raw","year":"2000","journal-title":"SIY Indoor Air Inf."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0155","doi-asserted-by":"crossref","first-page":"5826","DOI":"10.1016\/j.watres.2011.08.031","article-title":"An in-premise model for Legionella exposure during showering events","volume":"45","author":"Schoen","year":"2011","journal-title":"Water Res."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0160","doi-asserted-by":"crossref","first-page":"1685","DOI":"10.1001\/archinte.1996.00440140115011","article-title":"Risk factors for domestic acquisition of legionnaires disease. Ohio legionnaires Disease Group","volume":"156","author":"Straus","year":"1996","journal-title":"Arch. Intern. Med."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0165","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/S0140-6736(80)90005-7","article-title":"Legionnaires' disease in a transplant unit: isolation of the causative agent from shower baths","volume":"2","author":"Tobin","year":"1980","journal-title":"Lancet"},{"key":"10.1016\/j.ijheh.2016.12.001_bib0170","doi-asserted-by":"crossref","first-page":"1493","DOI":"10.1016\/0021-8502(94)90220-8","article-title":"A wind tunnel evaluation of the physical sampling efficiencies of three bioaerosol samplers","volume":"25","author":"Upton","year":"1994","journal-title":"J. Aerosol Sci."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0175","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1080\/00039890409603439","article-title":"Domestic exposure to legionellae for Dutch Legionnaires' disease patients","volume":"59","author":"Verhoef","year":"2004","journal-title":"Arch. Environ. Health"},{"key":"10.1016\/j.ijheh.2016.12.001_bib0180","doi-asserted-by":"crossref","first-page":"e114331","DOI":"10.1371\/journal.pone.0114331","article-title":"Necessity and effect of combating Legionella pneumophila in municipal shower systems","volume":"9","author":"Wiik","year":"2014","journal-title":"PLoS One"},{"key":"10.1016\/j.ijheh.2016.12.001_bib0185","doi-asserted-by":"crossref","first-page":"4797","DOI":"10.1021\/acs.est.5b00142","article-title":"Confirmed and potential sources of Legionella reviewed","volume":"49","author":"van Heijnsbergen","year":"2015","journal-title":"Environ. Sci. Technol."},{"key":"10.1016\/j.ijheh.2016.12.001_bib0190","doi-asserted-by":"crossref","first-page":"1356","DOI":"10.1086\/586741","article-title":"Community-acquired Legionella pneumonia: new insights from the German competence network for community acquired pneumonia","volume":"46","author":"von Baum","year":"2008","journal-title":"Clin. Infect. Dis."}],"container-title":["International Journal of Hygiene and Environmental Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1438463916305028?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1438463916305028?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,25]],"date-time":"2025-10-25T17:21:43Z","timestamp":1761412903000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1438463916305028"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4]]},"references-count":38,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017,4]]}},"alternative-id":["S1438463916305028"],"URL":"https:\/\/doi.org\/10.1016\/j.ijheh.2016.12.001","relation":{},"ISSN":["1438-4639"],"issn-type":[{"value":"1438-4639","type":"print"}],"subject":[],"published":{"date-parts":[[2017,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Occurrence of Legionella in UK household showers","name":"articletitle","label":"Article Title"},{"value":"International Journal of Hygiene and Environmental Health","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ijheh.2016.12.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Crown Copyright \u00a9 2016 Published by Elsevier GmbH. All rights reserved.","name":"copyright","label":"Copyright"}]}}