{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T13:36:36Z","timestamp":1760708196077},"reference-count":21,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2010,7,1]],"date-time":"2010-07-01T00:00:00Z","timestamp":1277942400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["International Journal of Obstetric Anesthesia"],"published-print":{"date-parts":[[2010,7]]},"DOI":"10.1016\/j.ijoa.2010.01.001","type":"journal-article","created":{"date-parts":[[2010,6,4]],"date-time":"2010-06-04T08:32:39Z","timestamp":1275640359000},"page":"282-286","source":"Crossref","is-referenced-by-count":10,"title":["An observational study of skin conductance monitoring as a means of predicting hypotension from spinal anaesthesia for caesarean delivery"],"prefix":"10.1016","volume":"19","author":[{"given":"T.","family":"Ledowski","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.J.","family":"Paech","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Browning","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Preuss","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.A.","family":"Schug","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ijoa.2010.01.001_bib1","doi-asserted-by":"crossref","unstructured":"Cyna AM, Andrew M, Emmett RS, Middleton P, Simmons SW. Techniques for preventing hypotension during spinal anaesthesia for caesarean section. Cochrane Database of Systematic Reviews 2006, Issue 4. Art. No.: CD002251. DOI: 10.1002\/14651858.CD002251.pub2.","DOI":"10.1002\/14651858.CD002251.pub2"},{"key":"10.1016\/j.ijoa.2010.01.001_bib2","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1016\/S0002-9378(96)70343-5","article-title":"Systemic vascular resistance index determined by thoracic electrical bioimpedance predicts the risk for maternal hypotension during regional anesthesia for cesarean delivery","volume":"174","author":"Ouzounian","year":"1996","journal-title":"Am J Obstet Gynecol"},{"issue":"Suppl. 1","key":"10.1016\/j.ijoa.2010.01.001_bib3","first-page":"SOAP A-3","article-title":"Prevention of hypotension following spinal anesthesia for cesarean section using noninvasive transthoracic electrical impedance cardiography (abstract)","volume":"102","author":"Garrison","year":"2005","journal-title":"Anesthesiology"},{"key":"10.1016\/j.ijoa.2010.01.001_bib4","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/BF03020493","article-title":"Baseline heart rate may predict hypotension after spinal anesthesia in prehydrated obstetrical patients","volume":"49","author":"Frohlich","year":"2002","journal-title":"Can J Anesth"},{"key":"10.1016\/j.ijoa.2010.01.001_bib5","doi-asserted-by":"crossref","first-page":"1818","DOI":"10.1213\/01.ANE.0000140953.40059.E6","article-title":"Using heart rate variability to stratify risk of obstetric patients undergoing spinal anesthesia","volume":"99","author":"Chamchad","year":"2004","journal-title":"Anesth Analg"},{"key":"10.1016\/j.ijoa.2010.01.001_bib6","doi-asserted-by":"crossref","first-page":"1086","DOI":"10.1097\/00000542-200506000-00005","article-title":"Heart rate variability predicts severe hypotension after spinal anesthesia for elective cesarean delivery","volume":"102","author":"Hanss","year":"2005","journal-title":"Anesthesiology"},{"key":"10.1016\/j.ijoa.2010.01.001_bib7","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1097\/00000542-200604000-00005","article-title":"Heart rate variability-guided prophylactic treatment of severe hypotension after subarachnoid block for elective caesarean delivery","volume":"104","author":"Hanss","year":"2006","journal-title":"Anesthesiology"},{"key":"10.1016\/j.ijoa.2010.01.001_bib8","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.1111\/j.1399-6576.2007.01435.x","article-title":"A greater decrease in blood pressure after spinal anaesthesia in patients with low entropy of the RR interval","volume":"51","author":"Fujiwara","year":"2007","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1016\/j.ijoa.2010.01.001_bib9","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1097\/ACO.0b013e3283183fe4","article-title":"Changes in skin conductance as a tool to monitor nociceptive stimulation and pain","volume":"21","author":"Storm","year":"2008","journal-title":"Curr Opin Anaesthesiol"},{"key":"10.1016\/j.ijoa.2010.01.001_bib10","doi-asserted-by":"crossref","first-page":"1342","DOI":"10.1111\/j.1399-6576.2008.01697.x","article-title":"Skin conductance as a means to predict hypotension following spinal anaesthesia","volume":"52","author":"Ledowski","year":"2008","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1016\/j.ijoa.2010.01.001_bib11","first-page":"445","article-title":"The Amsterdam preoperative anxiety and information scale (APAIS)","volume":"82","author":"Moerman","year":"1996","journal-title":"Anesth Analg"},{"key":"10.1016\/j.ijoa.2010.01.001_bib12","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1093\/bja\/aeh088","article-title":"Comparison of phenylephrine infusion regimens for maintaining maternal blood pressure during spinal anaesthesia for Caesarean section","volume":"92","author":"Ngan Kee","year":"2004","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.ijoa.2010.01.001_bib13","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/S0002-9378(16)36516-4","article-title":"Influence of post-spinal hypotension on the fetal electrocardiogram","volume":"80","author":"Ebner","year":"1960","journal-title":"Am J Obstet Gynecol"},{"key":"10.1016\/j.ijoa.2010.01.001_bib14","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1093\/bja\/ael119","article-title":"Skin conductance monitoring compared with Bispectral Index monitoring to assess emergence from general anaesthesia using sevoflurane and remifentanil","volume":"97","author":"Ledowski","year":"2006","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.ijoa.2010.01.001_bib15","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1111\/j.1365-2044.2007.05191.x","article-title":"The assessment of postoperative pain by monitoring of skin conductance. Results of a prospective study","volume":"62","author":"Ledowski","year":"2007","journal-title":"Anaesthesia"},{"key":"10.1016\/j.ijoa.2010.01.001_bib16","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/S0959-289X(96)80067-7","article-title":"Advance prediction of hypotension at cesarean delivery under spinal anesthesia","volume":"5","author":"Kinsella","year":"1996","journal-title":"Int J Obstet Anesth"},{"key":"10.1016\/j.ijoa.2010.01.001_bib17","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.ijoa.2006.10.006","article-title":"Prediction of hypotension during spinal anesthesia for cesarean section and its relation to the effect of crystalloid or colloid preload","volume":"16","author":"Dahlgren","year":"2006","journal-title":"Int J Obstet Anesth"},{"key":"10.1016\/j.ijoa.2010.01.001_bib18","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1093\/bja\/aei266","article-title":"Assessment of pulse transit time to indicate cardiovascular changes during obstetric spinal anaesthesia","volume":"96","author":"Sharwood-Smith","year":"2006","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.ijoa.2010.01.001_bib19","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1097\/00000542-199403000-00032","article-title":"Autonomic imbalance of the heart during total spinal anesthesia evaluated by spectral analysis of heart rate variability","volume":"80","author":"Kimura","year":"1994","journal-title":"Anesthesiology"},{"issue":"Suppl. 1","key":"10.1016\/j.ijoa.2010.01.001_bib20","first-page":"SOAP A-26","article-title":"ASP298 polymorphism of endothelial nitric oxide synthase does not affect response to treatment of hypotension during spinal anesthesia for cesarean section (abstract)","volume":"102","author":"Smiley","year":"2005","journal-title":"Anesthesiology"},{"key":"10.1016\/j.ijoa.2010.01.001_bib21","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1097\/00000542-200604000-00006","article-title":"Beta2-adrenoreceptor genotype affects vasopressor requirements during spinal anesthesia for cesarean delivery","volume":"104","author":"Smiley","year":"2006","journal-title":"Anesthesiology"}],"container-title":["International Journal of Obstetric Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0959289X10000166?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0959289X10000166?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,3,27]],"date-time":"2024-03-27T09:01:16Z","timestamp":1711530076000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0959289X10000166"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2010,7]]}},"alternative-id":["S0959289X10000166"],"URL":"https:\/\/doi.org\/10.1016\/j.ijoa.2010.01.001","relation":{},"ISSN":["0959-289X"],"issn-type":[{"value":"0959-289X","type":"print"}],"subject":[],"published":{"date-parts":[[2010,7]]}}}