{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T19:23:08Z","timestamp":1785439388824,"version":"3.56.0"},"reference-count":25,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2011,3,1]],"date-time":"2011-03-01T00:00:00Z","timestamp":1298937600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2011,3,1]],"date-time":"2011-03-01T00:00:00Z","timestamp":1298937600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","ijoms.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Oral and Maxillofacial Surgery"],"published-print":{"date-parts":[[2011,3]]},"DOI":"10.1016\/j.ijom.2010.10.004","type":"journal-article","created":{"date-parts":[[2010,11,11]],"date-time":"2010-11-11T04:45:57Z","timestamp":1289450757000},"page":"316-321","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":13,"title":["Evaluation of in vitro resistance of titanium and resorbable (poly-l-dl-lactic acid) fixation systems on the mandibular angle fracture"],"prefix":"10.1016","volume":"40","author":[{"given":"L.A.","family":"Bregagnolo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.F.","family":"Bertelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.C.","family":"Ribeiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.E.","family":"Sverzut","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.E.","family":"Trivellato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ijom.2010.10.004_bib0005","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1016\/0278-2391(94)90495-2","article-title":"Treatment of mandibular angle fractures: plate and screw fixation","volume":"52","author":"Assael","year":"1994","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0010","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1067\/moe.2000.111025","article-title":"Substitutes for human cadaveric bone in maxillofacial rigid fixation research","volume":"90","author":"Bredbenner","year":"2000","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.ijom.2010.10.004_bib0015","doi-asserted-by":"crossref","first-page":"980","DOI":"10.1177\/154405910608501102","article-title":"Efficacy and safety of biodegradable osteofixation devices in oral and maxillofacial surgery: a systematic review","volume":"85","author":"Buijs","year":"2006","journal-title":"J Dent Res"},{"key":"10.1016\/j.ijom.2010.10.004_bib0020","doi-asserted-by":"crossref","first-page":"2142","DOI":"10.1016\/j.joms.2007.08.002","article-title":"Torsion strength of biodegradable and titanium screws: a comparison","volume":"65","author":"Buijs","year":"2007","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0025","doi-asserted-by":"crossref","first-page":"2148","DOI":"10.1016\/j.joms.2007.04.010","article-title":"Mechanical strength and stiffness of biodegradable and titanium osteofixation systems","volume":"65","author":"Buijs","year":"2007","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0030","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1016\/j.joms.2005.03.013","article-title":"Comparison of strains produced by titanium and poly d,l-lactide acid plating systems to in vitro forces","volume":"63","author":"Chacon","year":"2005","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0035","first-page":"14","article-title":"Mandibular osteosynthesis by miniature screwed plates via a buccal approach","volume":"6","author":"Champy","year":"1978","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0040","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1053\/joms.2003.50094","article-title":"Computerized analysis of resorbable polymer plates and screws for the rigid fixation of the mandibular angle fractures","volume":"61","author":"Cox","year":"2003","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0045","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.jcms.2004.04.006","article-title":"Maxillofacial fractures. Analysis of demographic distribution and treatment in 2901 patients (25-year experience)","volume":"32","author":"Erol","year":"2004","journal-title":"J Craniomaxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0050","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1001\/archfaci.8.6.390","article-title":"Comparison of tensile strength of resorbable plating systems used in monocortical mandible angle osteotomy repair","volume":"8","author":"Jain","year":"2006","journal-title":"Arch Facial Plast Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0055","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.ajodo.2005.03.022","article-title":"One-year postoperative stability of LeFort I osteotomies with biodegradable fixation: a retrospective analysis of skeletal relapse","volume":"130","author":"Kiely","year":"2006","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.ijom.2010.10.004_bib0060","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1097\/01.prs.0000200915.65693.29","article-title":"Indications and limitations in resorbable P(L70\/30DL)LA osteosyntheses of displaced mandibular fractures in 4.5-year follow-up","volume":"117","author":"Landes","year":"2006","journal-title":"J Plast Reconstr Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0065","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1097\/01.PRS.0000041942.36666.4F","article-title":"Resorbable plate osteosynthesis of dislocated or pathological mandibular fractures: a prospective clinical trial of two amorphous l-\/dl-lactide copolymer 2-mm miniplate systems","volume":"111","author":"Landes","year":"2003","journal-title":"Plast Reconstr Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0070","series-title":"Cirurgia Oral e Maxilofacial Contempor\u00e2nea","first-page":"709","article-title":"Tratamento das fraturas faciais","author":"Ochs","year":"2005"},{"key":"10.1016\/j.ijom.2010.10.004_bib0075","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1097\/00001665-200011040-00011","article-title":"Critical concepts of absorbable internal fixation","volume":"11","author":"Pietrzak","year":"2000","journal-title":"J Craniofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0080","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1053\/joms.2000.16627","article-title":"The efficacy of bioresorbable fixation in the repair of mandibular fractures: an animal study","volume":"58","author":"Quereshy","year":"2000","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0085","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.1016\/j.joms.2005.04.019","article-title":"Strength analysis of titanium and resorbable internal fixation in a mandibulotomy model","volume":"63","author":"Ricalde","year":"2005","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0090","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/S1010-5182(97)80009-1","article-title":"One- or two-plate fixation of mandibular angle fractures?","volume":"25","author":"Schierle","year":"1997","journal-title":"J Craniomaxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0095","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/S1010-5182(97)80020-0","article-title":"Torsion-axial force characteristics of SR-PLLA screws","volume":"25","author":"Shetty","year":"1997","journal-title":"J Craniomaxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0100","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1016\/0278-2391(91)90065-T","article-title":"Comparison of absorbable self-reinforced poly-l-lactide screws and metallic screws in the fixation of mandibular condyle osteotomies: an experimental study in sheep","volume":"49","author":"Suuronen","year":"1991","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0105","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1016\/S0278-2391(99)90020-4","article-title":"A computer study of fracture mobility and strain on biodegradable plates used for fixation of mandibular fractures","volume":"57","author":"Tams","year":"1999","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0110","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1053\/joms.2001.21877","article-title":"A computer study of biodegradable plates for internal fixation of mandibular angle fractures","volume":"59","author":"Tams","year":"2001","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0115","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.joms.2005.09.011","article-title":"Self-reinforced biodegradable screw fixation compared with titanium screw fixation in mandibular advancement","volume":"64","author":"Turvey","year":"2006","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0120","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1016\/0278-2391(91)90178-O","article-title":"Biomechanical properties of resorbable poly-l-lactide plates and screws: a comparison with traditional systems","volume":"49","author":"Wittenberg","year":"1991","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.10.004_bib0125","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1067\/moe.2002.122833","article-title":"Fixation of mandibular fractures with biodegradable plates and screws","volume":"94","author":"Yerit","year":"2002","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"}],"container-title":["International Journal of Oral and Maxillofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0901502710004315?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0901502710004315?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T12:28:06Z","timestamp":1760272086000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0901502710004315"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,3]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2011,3]]}},"alternative-id":["S0901502710004315"],"URL":"https:\/\/doi.org\/10.1016\/j.ijom.2010.10.004","relation":{},"ISSN":["0901-5027"],"issn-type":[{"value":"0901-5027","type":"print"}],"subject":[],"published":{"date-parts":[[2011,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of in vitro resistance of titanium and resorbable (poly-l-dl-lactic acid) fixation systems on the mandibular angle fracture","name":"articletitle","label":"Article Title"},{"value":"International Journal of Oral and Maxillofacial Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ijom.2010.10.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2010 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}