{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T08:42:59Z","timestamp":1781685779381,"version":"3.54.5"},"reference-count":18,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2011,4,1]],"date-time":"2011-04-01T00:00:00Z","timestamp":1301616000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["International Journal of Oral and Maxillofacial Surgery"],"published-print":{"date-parts":[[2011,4]]},"DOI":"10.1016\/j.ijom.2010.11.012","type":"journal-article","created":{"date-parts":[[2010,12,31]],"date-time":"2010-12-31T09:41:32Z","timestamp":1293788492000},"page":"372-377","source":"Crossref","is-referenced-by-count":37,"title":["Comparative evaluation of 2.0-mm locking plate system vs 2.0-mm nonlocking plate system for mandibular fracture: a prospective randomized study"],"prefix":"10.1016","volume":"40","author":[{"given":"V.","family":"Singh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I.","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Bhagol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ijom.2010.11.012_bib0005","doi-asserted-by":"crossref","first-page":"120","DOI":"10.2302\/kjm.52.120","article-title":"New innovations in craniomaxillofacial fixation: the 2.0 lock system","volume":"52","author":"Alpert","year":"2003","journal-title":"Keio J Med"},{"key":"10.1016\/j.ijom.2010.11.012_bib0010","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1053\/joms.2002.29813","article-title":"Transoral 2.0-mm miniplate fixation of mandibular fractures plus 2 weeks\u2019 maxillomandibular fixation: a prospective study","volume":"60","author":"Bolourian","year":"2002","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0015","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1016\/j.joms.2006.03.027","article-title":"Failure strength of 2.0 locking versus 2.0 conventional synthes mandibular plates: a laboratory model","volume":"64","author":"Chiodo","year":"2006","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0020","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.1016\/j.joms.2005.08.022","article-title":"Transoral 2mm locking miniplate fixation of mandibular fractures plus 1 week of maxillomandibular fixation: a prospective study","volume":"63","author":"Chritah","year":"2005","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0025","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.1016\/j.joms.2004.04.020","article-title":"A prospective randomized clinical trial comparing 2mm locking plates to 2mm standard plates in treatment of mandibular fractures","volume":"62","author":"Collins","year":"2004","journal-title":"J. Oral Maxillofacial Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0030","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1055\/s-2002-34430","article-title":"Selection of internal fixation devices for mandibular fractures: how much fixation is enough?","volume":"16","author":"Ellis","year":"2002","journal-title":"Semin Plast Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0035","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1053\/joms.2002.33110","article-title":"Use of a 2.0-mm locking plate\/screw system for mandibular fracture surgery","volume":"60","author":"Ellis","year":"2002","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0040","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1016\/S0278-2391(96)90538-8","article-title":"Treatment of mandibular angle fractures using one noncompression miniplate","volume":"54","author":"Ellis","year":"1996","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0045","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1054\/ijom.2000.0182","article-title":"Combination of microplate and miniplate for osteosynthesis of mandibular fractures","volume":"31","author":"Feller","year":"2002","journal-title":"Int J Oral Maxillofacial Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0050","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1053\/joms.2003.50083","article-title":"Fixation of mandibular fracture with 2mm miniplates; Review of 191 cases","volume":"61","author":"Gabrielli","year":"2003","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0055","first-page":"280","article-title":"Biomechanical stability of an internal mini-fixation system in maxillofacial osteosynthesis","volume":"37","author":"Gutwald","year":"1999","journal-title":"J Med Biol Eng Comp"},{"key":"10.1016\/j.ijom.2010.11.012_bib0060","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.1053\/joms.2002.35732","article-title":"Does plate adaptation affect stability? A biomechanical comparison of locking and nonlocking plates","volume":"60","author":"Haug","year":"2002","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0065","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1016\/S0278-2391(98)90605-X","article-title":"Use of a locking reconstruction bone plate\/screw system for mandibular surgery","volume":"56","author":"Herford","year":"1998","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0070","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1053\/joms.2000.7258","article-title":"Nonunion of mandible: an analysis of contributing factors","volume":"58","author":"Mathog","year":"2000","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0075","first-page":"535","article-title":"Surgical procedures for reconstruction of the lower jaw using the titanium-coated hollow-screw reconstruction plate system: bridging of defects","volume":"20","author":"Raveh","year":"1987","journal-title":"Otolaryngol Clin North Am"},{"key":"10.1016\/j.ijom.2010.11.012_bib0080","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1038\/sj.bdj.4802850","article-title":"Quick-release locking plates","volume":"132","author":"Seward","year":"1972","journal-title":"Br Dent J"},{"key":"10.1016\/j.ijom.2010.11.012_bib0085","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1016\/0278-2391(91)90145-C","article-title":"Bridging of mandibular defects with two different reconstruction systems: an experimental study","volume":"49","author":"Soderholm","year":"1991","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.ijom.2010.11.012_bib0090","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/S0901-5027(88)80055-9","article-title":"Titanium-coated hollow screw and reconstruction plate system for bridging of lower jaw defects: biomechanical aspects","volume":"17","author":"Sutter","year":"1988","journal-title":"Int J Oral Maxillofac Surg"}],"container-title":["International Journal of Oral and Maxillofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0901502710005059?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0901502710005059?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,12,5]],"date-time":"2018-12-05T21:26:52Z","timestamp":1544045212000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0901502710005059"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,4]]},"references-count":18,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2011,4]]}},"alternative-id":["S0901502710005059"],"URL":"https:\/\/doi.org\/10.1016\/j.ijom.2010.11.012","relation":{},"ISSN":["0901-5027"],"issn-type":[{"value":"0901-5027","type":"print"}],"subject":[],"published":{"date-parts":[[2011,4]]}}}