{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T01:27:44Z","timestamp":1782869264164,"version":"3.54.5"},"reference-count":14,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,4,10]],"date-time":"2024-04-10T00:00:00Z","timestamp":1712707200000},"content-version":"vor","delay-in-days":40,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Particle Therapy"],"published-print":{"date-parts":[[2024,3]]},"DOI":"10.1016\/j.ijpt.2024.01.001","type":"journal-article","created":{"date-parts":[[2024,4,21]],"date-time":"2024-04-21T17:19:43Z","timestamp":1713719983000},"page":"100001","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"special_numbering":"C","title":["Real-Time Gated Proton Therapy: Commissioning and Clinical Workflow for the Hitachi System"],"prefix":"10.1016","volume":"11","author":[{"given":"Hao","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6222-311X","authenticated-orcid":false,"given":"Emile","family":"Gogineni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yilin","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Wong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4846-6486","authenticated-orcid":false,"given":"Curtiland","family":"Deville","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heng","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"6","key":"10.1016\/j.ijpt.2024.01.001_bib1","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1002\/acm2.12459","article-title":"Small-spot intensity-modulated proton therapy and volumetric-modulated arc therapies for patients with locally advanced non-small-cell lung cancer: a dosimetric comparative study","volume":"19","author":"Liu","year":"2018","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ijpt.2024.01.001_bib2","first-page":"48","article-title":"Dosimetric comparison to the heart and cardiac substructure in a large cohort of esophageal cancer patients treated with proton beam therapy or Intensity-modulated radiation therapy","volume":"125","author":"Shiraishi","year":"2017","journal-title":"Radiother\u00a0Oncol"},{"key":"10.1016\/j.ijpt.2024.01.001_bib3","first-page":"e50","article-title":"AAPM Task Group Report 290: respiratory motion management for particle therapy","volume":"49","author":"Li","year":"2022","journal-title":"Med\u00a0Phys"},{"issue":"1","key":"10.1016\/j.ijpt.2024.01.001_bib4","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1053\/j.semradonc.2003.10.009","article-title":"Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment","volume":"14","author":"Mageras","year":"2004","journal-title":"Semin Radiat Oncol"},{"issue":"5","key":"10.1016\/j.ijpt.2024.01.001_bib5","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1016\/j.prro.2013.10.002","article-title":"A prospective feasibility study of respiratory-gated proton beam therapy for liver tumors","volume":"4","author":"Hong","year":"2014","journal-title":"Pract Radiat Oncol"},{"issue":"8","key":"10.1016\/j.ijpt.2024.01.001_bib6","doi-asserted-by":"crossref","first-page":"3273","DOI":"10.1118\/1.2756602","article-title":"A respiratory-gated treatment system for proton therapy","volume":"34","author":"Lu","year":"2007","journal-title":"Med Phys"},{"issue":"5","key":"10.1016\/j.ijpt.2024.01.001_bib7","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1002\/acm2.12584","article-title":"Clinical implementation of respiratory-gated spot-scanning proton therapy: an efficiency analysis of active motion management","volume":"20","author":"Gelover","year":"2019","journal-title":"J Appl Clin Med Phys"},{"issue":"9","key":"10.1016\/j.ijpt.2024.01.001_bib8","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1007\/s00066-015-0861-z","article-title":"Surface imaging, portal imaging, and skin marker set-up vs. CBCT for radiotherapy of the thorax and pelvis","volume":"191","author":"Pallotta","year":"2015","journal-title":"Strahlenther Onkol"},{"issue":"4","key":"10.1016\/j.ijpt.2024.01.001_bib9","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0094971","article-title":"A proton beam therapy system dedicated to spot-scanning increases accuracy with moving tumors by real-time imaging and gating and reduces equipment size","volume":"9","author":"Shimizu","year":"2014","journal-title":"PLoS One"},{"issue":"3","key":"10.1016\/j.ijpt.2024.01.001_bib10","article-title":"A single-institution prospective study to evaluate the safety and efficacy of real-time-image gated spot-scanning proton therapy (RGPT) for prostate cancer","volume":"114","author":"Nishioka","year":"2022","journal-title":"Int\u00a0J\u00a0Radiat\u00a0Oncol\u00a0Biol\u00a0Phys"},{"issue":"7","key":"10.1016\/j.ijpt.2024.01.001_bib11","doi-asserted-by":"crossref","first-page":"E471","DOI":"10.1002\/ccd.27793","article-title":"Variability in radiation dose and image quality: a comparison across fluoroscopy-system vendors, generations of equipment and institutions","volume":"92","author":"Hill","year":"2018","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.ijpt.2024.01.001_bib12","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1002\/acm2.12804","article-title":"Analysis of treatment process time for real-time-image gated-spot-scanning proton-beam therapy (RGPT) system","volume":"21","author":"Yoshimura","year":"2020","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.ijpt.2024.01.001_bib13","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1002\/acm2.13029","article-title":"Quantitative analysis of treatments using real-time image gated spot-scanning with synchrotron-based proton beam therapy system log data","volume":"21","author":"Yoshimura","year":"2020","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"10.1016\/j.ijpt.2024.01.001_bib14","first-page":"e542","article-title":"Initial experience with real-time gated proton therapy (RGPT) in the definitive treatment of prostate cancer","volume":"114","author":"Cao","year":"2022","journal-title":"Int J\u00a0Radiat\u00a0Oncol\u00a0Biol\u00a0Phys"}],"container-title":["International Journal of Particle Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2331518024000672?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2331518024000672?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,5,29]],"date-time":"2024-05-29T10:00:24Z","timestamp":1716976824000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2331518024000672"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3]]},"references-count":14,"alternative-id":["S2331518024000672"],"URL":"https:\/\/doi.org\/10.1016\/j.ijpt.2024.01.001","relation":{},"ISSN":["2331-5180"],"issn-type":[{"value":"2331-5180","type":"print"}],"subject":[],"published":{"date-parts":[[2024,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Real-Time Gated Proton Therapy: Commissioning and Clinical Workflow for the Hitachi System","name":"articletitle","label":"Article Title"},{"value":"International Journal of Particle Therapy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ijpt.2024.01.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier B.V. on behalf of Particle Therapy Co-operative Group.","name":"copyright","label":"Copyright"}],"article-number":"100001"}}