{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T06:01:23Z","timestamp":1792044083876,"version":"4.4.0"},"reference-count":15,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T00:00:00Z","timestamp":1759449600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100022244","name":"Baptist Health South Florida","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100022244","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Particle Therapy"],"published-print":{"date-parts":[[2025,12]]},"DOI":"10.1016\/j.ijpt.2025.101208","type":"journal-article","created":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T23:46:32Z","timestamp":1759794392000},"page":"101208","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["Benchmarking Modern Day Pencil Beam Scanning Proton Therapy Treatment Times: Insights From Real Time Location Service Treatment Time Data"],"prefix":"10.1016","volume":"18","author":[{"given":"Kristen","family":"McConnell","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"Wroe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria","family":"Valladares","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorrie","family":"LeGrand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulrich","family":"Ramos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Chuong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minesh","family":"Mehta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alonso","family":"Gutierrez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"7","key":"10.1016\/j.ijpt.2025.101208_bib1","first-page":"4329","article-title":"Quantitative analysis of beam delivery parameters and treatment process time for proton beam therapy","volume":"38","author":"Suzuki","year":"2011","journal-title":"Med\u00a0Phys"},{"issue":"4","key":"10.1016\/j.ijpt.2025.101208_bib2","doi-asserted-by":"crossref","first-page":"258","DOI":"10.14316\/pmp.2016.27.4.258","article-title":"Analysis of treatment and delay times by disease site and delivery technique at samsung medical center: proton therapy center","volume":"27","author":"Jo","year":"2016","journal-title":"Prog Med Phys"},{"key":"10.1016\/j.ijpt.2025.101208_bib3","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1007\/s10916-019-1174-z","article-title":"Improving clinic operational efficiency and utilization with RTLS","volume":"43","author":"Berg","year":"2019","journal-title":"Med Syst"},{"issue":"5","key":"10.1016\/j.ijpt.2025.101208_bib4","first-page":"317","article-title":"Using a real-time location system to measure patient flow in a radiation oncology outpatient clinic","volume":"8","author":"Conley","year":"2018","journal-title":"Pract\u00a0Radiat\u00a0Oncol"},{"issue":"3","key":"10.1016\/j.ijpt.2025.101208_bib5","first-page":"435","article-title":"RFID-initiated workflow control to facilitate patient safety and utilization efficiency in operation theater","volume":"104","author":"Liu","year":"2011","journal-title":"Comput\u00a0Methods\u00a0Programs\u00a0Biomed"},{"issue":"6","key":"10.1016\/j.ijpt.2025.101208_bib6","first-page":"545","article-title":"Smart medical environment at the point of care: auto-tracking clinical interventions at the bed side using RFID technology","volume":"40","author":"Ohashi","year":"2010","journal-title":"Comput\u00a0Biol\u00a0Med"},{"issue":"3","key":"10.1016\/j.ijpt.2025.101208_bib7","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1177\/1460458215572923","article-title":"Radio frequency identification\u2013enabled capabilities in a healthcare context: an exploratory study","volume":"22","author":"Hornyak","year":"2016","journal-title":"Health Informatics J"},{"issue":"1","key":"10.1016\/j.ijpt.2025.101208_bib8","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1177\/183335831104000105","article-title":"Professional Practice and Innovation: RF-MediSys: a radio frequency identification-based electronic medical record system for improving medical information accessibility and services at point of care","volume":"40","author":"Ting","year":"2011","journal-title":"HIM J"},{"issue":"12","key":"10.1016\/j.ijpt.2025.101208_bib9","doi-asserted-by":"crossref","first-page":"29821","DOI":"10.3390\/s151229769","article-title":"Process mining methodology for health process tracking using real-time indoor location systems","volume":"15","author":"Fernandez-Llatas","year":"2015","journal-title":"Sensors"},{"issue":"4","key":"10.1016\/j.ijpt.2025.101208_bib10","first-page":"344","article-title":"Evaluation of hand hygiene compliance and associated factors with a radio-frequency-identification-based real-time continuous automated monitoring system","volume":"95","author":"Dufour","year":"2017","journal-title":"J\u00a0Hosp\u00a0Infect"},{"issue":"12","key":"10.1016\/j.ijpt.2025.101208_bib11","first-page":"872","article-title":"A novel method for inferring RFID tag reader recordings into clinical events","volume":"80","author":"Chang","year":"2011","journal-title":"Int\u00a0J\u00a0Med\u00a0Inform"},{"key":"10.1016\/j.ijpt.2025.101208_bib12","unstructured":"Particle Therapy Co-Operative Group. June 13, 2024. \u3008https:\/\/ptcog.site\/\u3009."},{"key":"10.1016\/j.ijpt.2025.101208_bib13","doi-asserted-by":"crossref","unstructured":"Hartsell WF, Simone CB, Godes D, et al. Temporal evolution and diagnostic diversification of patients receiving proton therapy in the United States: a ten-year trend analysis (2012 to 2021) from the National Association for Proton Therapy. International Journal of Radiation Oncology*Biology*Physics. Published online December 2023:S0360301623083153. doi:10.1016\/j.ijrobp.2023.12.041.","DOI":"10.1016\/j.ijrobp.2023.12.041"},{"issue":"1","key":"10.1016\/j.ijpt.2025.101208_bib14","first-page":"40","article-title":"The interaction of waiting time and patient experience during radiation therapy: a survey of patients from a tertiary cancer center","volume":"51","author":"Lamba","year":"2020","journal-title":"J\u00a0Med\u00a0Imaging\u00a0Radiat\u00a0Sci"},{"issue":"3","key":"10.1016\/j.ijpt.2025.101208_bib15","first-page":"599","article-title":"Analysis of person-hours required for proton beam therapy for pediatric tumors","volume":"64","author":"Mizumoto","year":"2023","journal-title":"J\u00a0Radiat\u00a0Res"}],"container-title":["International Journal of Particle Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2331518025004731?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2331518025004731?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,25]],"date-time":"2025-10-25T04:55:11Z","timestamp":1761368111000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2331518025004731"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":15,"alternative-id":["S2331518025004731"],"URL":"https:\/\/doi.org\/10.1016\/j.ijpt.2025.101208","relation":{},"ISSN":["2331-5180"],"issn-type":[{"value":"2331-5180","type":"print"}],"subject":[],"published":{"date-parts":[[2025,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Benchmarking Modern Day Pencil Beam Scanning Proton Therapy Treatment Times: Insights From Real Time Location Service Treatment Time Data","name":"articletitle","label":"Article Title"},{"value":"International Journal of Particle Therapy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ijpt.2025.101208","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier B.V. on behalf of Particle Therapy Co-operative Group.","name":"copyright","label":"Copyright"}],"article-number":"101208"}}