{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T23:48:50Z","timestamp":1791071330567,"version":"4.1.0"},"reference-count":49,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2007,6,1]],"date-time":"2007-06-01T00:00:00Z","timestamp":1180656000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["International Journal of Radiation Oncology*Biology*Physics"],"published-print":{"date-parts":[[2007,6]]},"DOI":"10.1016\/j.ijrobp.2006.12.024","type":"journal-article","created":{"date-parts":[[2007,2,28]],"date-time":"2007-02-28T12:31:22Z","timestamp":1172665882000},"page":"581-591","source":"Crossref","is-referenced-by-count":110,"title":["Interfractional Variations in Patient Setup and Anatomic Change Assessed by Daily Computed Tomography"],"prefix":"10.1016","volume":"68","author":[{"given":"X. Allen","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"X. Sharon","family":"Qi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marissa","family":"Pitterle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kapila","family":"Kalakota","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"Mueller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beth A.","family":"Erickson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dian","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Schultz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Selim Y.","family":"Firat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Frank","family":"Wilson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ijrobp.2006.12.024_bib1","doi-asserted-by":"crossref","first-page":"2397","DOI":"10.1118\/1.598756","article-title":"Quantization of setup uncertainties in 3D dose calculations","volume":"26","author":"Lujan","year":"1999","journal-title":"Med Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib2","doi-asserted-by":"crossref","first-page":"1407","DOI":"10.1016\/S0360-3016(01)02805-X","article-title":"Inclusion of geometric uncertainties in treatment plan evaluation","volume":"52","author":"van Herk","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib3","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1016\/S0360-3016(01)01624-8","article-title":"A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload","volume":"50","author":"de Boer","year":"2001","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib4","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1118\/1.1357224","article-title":"Organ\/patient geometric variation in external beam radiotherapy and its effects","volume":"28","author":"Yan","year":"2001","journal-title":"Med Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib5","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/S0167-8140(00)00280-2","article-title":"Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors","volume":"58","author":"Gilbeau","year":"2001","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib6","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1016\/S0360-3016(00)00476-4","article-title":"Setup error in radiotherapy: On-line correction using electronic kilovoltage and megavoltage radiographs","volume":"47","author":"Pisani","year":"2000","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib7","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/S0360-3016(98)00354-X","article-title":"Setup reproducibility in radiation therapy for lung cancer: A comparison between T-bar and expanded foam immobilization devices","volume":"43","author":"Halperin","year":"1999","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib8","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1016\/S0360-3016(97)00567-1","article-title":"The use of adaptive radiation therapy to reduce setup error: A prospective clinical study","volume":"41","author":"Yan","year":"1998","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib9","doi-asserted-by":"crossref","first-page":"35.E1","DOI":"10.1016\/j.radonc.2005.06.006","article-title":"Dosimetric consequences of the application of off-line setup error correction protocols and a hull-volume definition strategy for intensity modulated radiotherapy of prostate cancer","volume":"76","author":"Baum","year":"2005","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib10","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.meddos.2005.03.003","article-title":"Correction of systematic setup errors in prostate radiation therapy: How many images to perform?","volume":"30","author":"Ludbrook","year":"2005","journal-title":"Med Dosim"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib11","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.meddos.2004.10.007","article-title":"Setup errors in patients treated with intensity-modulated whole pelvic radiation therapy for gynecological malignancies","volume":"30","author":"Haslam","year":"2005","journal-title":"Med Dosim"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib12","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1016\/j.ijrobp.2004.07.696","article-title":"The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy","volume":"61","author":"Hong","year":"2005","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib13","doi-asserted-by":"crossref","first-page":"3363","DOI":"10.1118\/1.1809768","article-title":"Adaptive radiation therapy for compensation of errors in patient setup and treatment delivery","volume":"31","author":"Rehbinder","year":"2004","journal-title":"Med Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib14","doi-asserted-by":"crossref","first-page":"2590","DOI":"10.1118\/1.1992207","article-title":"Reproducibility of the bladder shape and bladder shape changes during filling","volume":"32","author":"Lotz","year":"2005","journal-title":"Med Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib15","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/S0167-8140(01)00466-2","article-title":"Time trends in organ position and volume in patients receiving prostate three-dimensional conformal radiotherapy","volume":"62","author":"Mechalakos","year":"2002","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib16","doi-asserted-by":"crossref","first-page":"2337","DOI":"10.1088\/0031-9155\/46\/9\/305","article-title":"Numerical analysis of a model of organ motion using serial imaging measurements from prostate radiotherapy","volume":"46","author":"Fontenla","year":"2001","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib17","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1016\/S0360-3016(00)01446-2","article-title":"Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate","volume":"49","author":"Alasti","year":"2001","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib18","doi-asserted-by":"crossref","first-page":"2317","DOI":"10.1088\/0031-9155\/46\/9\/304","article-title":"Using serial imaging data to model variabilities in organ position and shape during radiotherapy","volume":"46","author":"Fontenla","year":"2001","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib19","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1016\/S0360-3016(01)01815-6","article-title":"Daily targeting of intrahepatic tumors for radiotherapy","volume":"52","author":"Balter","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib20","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.radonc.2005.06.007","article-title":"The impact of organ motion on intestine doses and complication probabilities in radiotherapy of bladder cancer","volume":"76","author":"Kvinnsland","year":"2005","journal-title":"Radiother Oncol"},{"issue":"Suppl. 2","key":"10.1016\/j.ijrobp.2006.12.024_bib21","doi-asserted-by":"crossref","first-page":"S68","DOI":"10.1016\/S0167-8140(04)80018-5","article-title":"Moving targets: Detection and tracking of internal organ motion for treatment planning and patient set-up","volume":"73","author":"Rietzel","year":"2004","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib22","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1016\/S0360-3016(98)00468-4","article-title":"Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability","volume":"43","author":"Stroom","year":"1999","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib23","doi-asserted-by":"crossref","first-page":"1407","DOI":"10.1016\/S0360-3016(01)02805-X","article-title":"Inclusion of geometric uncertainties in treatment plan evaluation","volume":"52","author":"van Herk","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib24","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1016\/S0360-3016(00)00518-6","article-title":"The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy","volume":"47","author":"van Herk","year":"2000","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib25","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1016\/S0360-3016(99)00117-0","article-title":"Planning target volumes for radiotherapy: How much margin is needed?","volume":"44","author":"Antolak","year":"1999","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib26","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.semradonc.2005.01.003","article-title":"Emergent technologies for 3-dimensional image-guided radiation delivery","volume":"15","author":"Jaffray","year":"2005","journal-title":"Semin Radiat Oncol"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib27","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/S0360-3016(03)00090-7","article-title":"Image guidance for precise conformal radiotherapy","volume":"56","author":"Mackie","year":"2003","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib28","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.semradonc.2005.01.007","article-title":"Computed tomography guided management of interfractional patient variation","volume":"15","author":"Yan","year":"2005","journal-title":"Semin Radiat Oncol"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib29","doi-asserted-by":"crossref","first-page":"1709","DOI":"10.1118\/1.596958","article-title":"Tomotherapy: A new concept for the delivery of dynamic conformal radiotherapy","volume":"20","author":"Mackie","year":"1993","journal-title":"Med Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib30","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/S1053-4296(99)80058-7","article-title":"Tomotherapy","volume":"9","author":"Mackie","year":"1999","journal-title":"Semin Radiat Oncol"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib31","first-page":"29","article-title":"Set-up error & organ motion uncertainty: A review","volume":"22","author":"Booth","year":"1999","journal-title":"Austa Phys Eng Sci Med"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib32","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1016\/S0360-3016(97)00925-5","article-title":"Electronic portal imaging with on-line correction of setup error in thoracic irradiation: Clinical evaluation","volume":"40","author":"Van de Steene","year":"1998","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib33","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/0958-3947(96)00022-2","article-title":"Measurements of patient setup errors using port films and a computer aided graphical alignment tool","volume":"21","author":"Schewe","year":"1996","journal-title":"Med Dosim"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib34","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1016\/S0360-3016(03)00290-6","article-title":"Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT: Implications for treatment margins","volume":"56","author":"Little","year":"2003","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib35","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1177\/153303460300200511","article-title":"3D-ultrasound guided therapy in the post-prostatectomy setting","volume":"5","author":"Chinnaiyan","year":"2003","journal-title":"Technol Cancer Res Treat"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib36","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.ijrobp.2003.12.027","article-title":"Daily electronic portal imaging for morbidly obese men undergoing radiotherapy for localized prostate cancer","volume":"59","author":"Millender","year":"2004","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib37","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1016\/j.ijrobp.2005.04.046","article-title":"Serial megavoltage CT imaging during external beam radiotherapy for non-small-cell lung cancer: Observations on tumor regression during treatment","volume":"63","author":"Kupelian","year":"2005","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib38","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1016\/j.ijrobp.2003.12.024","article-title":"Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT\/linear accelerator system","volume":"59","author":"Barker","year":"2004","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib39","doi-asserted-by":"crossref","first-page":"1602","DOI":"10.1016\/j.ijrobp.2004.07.709","article-title":"Online image-guided intensity-modulated radiotherapy for prostate cancer: How much improvement can we expect?","volume":"60","author":"Ghilezan","year":"2004","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib40","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1016\/j.ijrobp.2004.10.010","article-title":"Evaluating changes in tumor volume using magnetic resonance imaging during the course of radiotherapy treatment of high-grade gliomas: Implications for conformal dose-escalation studies","volume":"62","author":"Tsien","year":"2005","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib41","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/S0360-3016(01)01615-7","article-title":"Assessment of lung cancer response after nonoperative therapy: Tumor diameter, bidimensional product, and volume","volume":"51","author":"Werner-Wasik","year":"2001","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib42","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1016\/j.ijrobp.2005.07.957","article-title":"Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer","volume":"64","author":"Hansen","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib43","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/S0167-8140(03)00246-9","article-title":"Organ motion, set-up variation and treatment margins in radical radiotherapy of urinary bladder cancer","volume":"69","author":"Muren","year":"2003","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib44","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/S0167-8140(99)00068-7","article-title":"Impact of the filling status of the bladder and rectum on their integral dose distribution and the movement of the uterus in the treatment planning of gynaecological cancer","volume":"53","author":"Buchali","year":"1999","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib45","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1148\/radiol.2223010639","article-title":"Conformal therapy for pancreatic cancer: Variation of organ position due to gastrointestinal distention-implications for treatment planning","volume":"222","author":"Horst","year":"2002","journal-title":"Radiology"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib46","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.ijrobp.2005.12.042","article-title":"Abdominal organ motion measured using 4D CT","volume":"65","author":"Brandner","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib47","doi-asserted-by":"crossref","first-page":"1258","DOI":"10.1016\/j.ijrobp.2004.11.033","article-title":"Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes","volume":"61","author":"Mohan","year":"2005","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib48","doi-asserted-by":"crossref","first-page":"3874","DOI":"10.1118\/1.2349696","article-title":"The management of respiratory motion in radiation oncology report of AAPM Task Group 76","volume":"33","author":"Keall","year":"2006","journal-title":"Med Phys"},{"key":"10.1016\/j.ijrobp.2006.12.024_bib49","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1118\/1.2147743","article-title":"Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system","volume":"33","author":"Li","year":"2006","journal-title":"Med Phys"}],"container-title":["International Journal of Radiation Oncology*Biology*Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0360301606036534?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0360301606036534?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,4,25]],"date-time":"2019-04-25T00:16:43Z","timestamp":1556151403000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0360301606036534"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,6]]},"references-count":49,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2007,6]]}},"alternative-id":["S0360301606036534"],"URL":"https:\/\/doi.org\/10.1016\/j.ijrobp.2006.12.024","relation":{},"ISSN":["0360-3016"],"issn-type":[{"value":"0360-3016","type":"print"}],"subject":[],"published":{"date-parts":[[2007,6]]}}}