{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T23:41:49Z","timestamp":1768434109524,"version":"3.49.0"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2014,1,1]],"date-time":"2014-01-01T00:00:00Z","timestamp":1388534400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,2,5]],"date-time":"2014-02-05T00:00:00Z","timestamp":1391558400000},"content-version":"vor","delay-in-days":35,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/3.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2014,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>INTRODUCTION:<\/jats:title>\n                    <jats:p>Fracture and embolization of central venous catheters placed via the subclavian approach is well recognized, but fractured catheters placed via the internal jugular vein are extremely rare.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>PRESENTATION OF CASE:<\/jats:title>\n                    <jats:p>A 65-year-old man presented with a catheter embolus after placement of a central venous port using the internal jugular approach undertaken to administer adjuvant chemotherapy for colon cancer with lung metastases. Goose neck and conformational loop snares were successfully used to percutaneously retrieve the severed catheter, which had migrated to the right ventricle.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>DISCUSSION:<\/jats:title>\n                    <jats:p>Catheter fracture may occur even after placement via the internal jugular approach and may be underestimated because it is often asymptomatic. Interventional radiology techniques using goose-neck and conformational loop snares may be useful to retract an intravascular foreign body.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Imaging studies such as a chest X-ray are mandatory to check that the catheter tip is in the appropriate position during the entire follow-up period even if it was placed through the internal jugular vein.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2014.02.001","type":"journal-article","created":{"date-parts":[[2014,3,22]],"date-time":"2014-03-22T00:23:10Z","timestamp":1395447790000},"page":"219-221","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Embolization of a fractured central venous catheter placed using the internal jugular approach"],"prefix":"10.1097","volume":"5","author":[{"given":"Atsushi","family":"Shimizu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alan","family":"Lefor","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manabu","family":"Nakata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Umehachi","family":"Mitsuhashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masahiro","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshikazu","family":"Yasuda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-2-20260114","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/0002-9610(84)90340-4","article-title":"The pinch-off sign: a warning of impending problems with permanent subclavian catheters","volume":"148","author":"Aitken","year":"1984","journal-title":"Am J Surg"},{"key":"R2-2-20260114","doi-asserted-by":"crossref","first-page":"27","DOI":"10.2147\/RMHP.S10383","article-title":"Anatomic considerations for central venous cannulation","volume":"4","author":"Bannon","year":"2011","journal-title":"Risk Manag Healthc Policy"},{"key":"R3-2-20260114","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1002\/ca.20605","article-title":"Anatomical basis of central venous catheter fracture","volume":"21","author":"Jensen","year":"2008","journal-title":"Clin Anat"},{"key":"R4-2-20260114","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1177\/0148607109335121","article-title":"Intravascular embolization of venous catheter-causes, clinical signs, and management: a systematic review","volume":"33","author":"Surov","year":"2009","journal-title":"JPEN J Parenter Enteral Nutr"},{"key":"R5-2-20260114","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/j.jamcollsurg.2007.01.039","article-title":"Complications of central venous catheterization","volume":"204","author":"Kusminsky","year":"2007","journal-title":"J Am Coll Surg"},{"key":"R6-2-20260114","doi-asserted-by":"crossref","first-page":"2403","DOI":"10.1007\/s00268-011-1200-x","article-title":"Catheter fracture of intravenous ports and its management","volume":"35","author":"Wu","year":"2011","journal-title":"World J Surg"},{"key":"R7-2-20260114","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.ejso.2009.07.011","article-title":"The mechanisms of failure of totally implantable central venous access system: analysis of 73 cases with fracture of catheter","volume":"36","author":"Lin","year":"2010","journal-title":"Eur J Surg Oncol"},{"key":"R8-2-20260114","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.crad.2012.10.013","article-title":"Imaging and management of complications of central venous catheters","volume":"68","author":"Nayeemuddin","year":"2013","journal-title":"Clin Radiol"},{"key":"R9-2-20260114","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1002\/jso.21758","article-title":"A case of catheter fracture of a totally implantable access port introduced through the right internal jugular vein","volume":"103","author":"Shimizu","year":"2011","journal-title":"J Surg Oncol"},{"key":"R12-2-20260114","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/S0899-7071(03)00119-0","article-title":"Percutaneous retrieval of 20 centrally dislodged Port-A catheter fragments","volume":"28","author":"Liu","year":"2004","journal-title":"Clin Imaging"},{"key":"R13-2-20260114","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1016\/j.ejrad.2007.09.034","article-title":"Percutaneous retrieval of dislodged totally implantable central venous access system in 92 cases: experience in a single hospital","volume":"69","author":"Cheng","year":"2009","journal-title":"Eur J Radiol"},{"key":"R14-2-20260114","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1177\/000313480407000715","article-title":"Pinch-off syndrome: case report and collective review of the literature","volume":"70","author":"Mirza","year":"2004","journal-title":"Am Surg"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261214000303?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261214000303?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/01612930-201405050-00002","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T13:18:33Z","timestamp":1768396713000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01612930-201405050-00002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,1]]},"references-count":12,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2014]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2014.02.001","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2014,1]]}}}