{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T06:24:22Z","timestamp":1792563862530,"version":"4.5.0"},"reference-count":35,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"C","license":[{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,9,4]],"date-time":"2020-09-04T00:00:00Z","timestamp":1599177600000},"content-version":"vor","delay-in-days":247,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Recurrent dislocation after total hip arthroplasty (THA) using the dual mobility cup system can present challenges, while dual-mobility THA bearings can improve stability in both primary and revision total hip arthroplasties.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Presentation of case<\/jats:title>\n                    <jats:p>A 72-year-old woman with a history of schizophrenia underwent a left primary THA using the G7 dual mobility system. Two postoperative posterior dislocations occurred within 2 months post-surgery. The patient underwent revision surgery in which the metal liner and dual mobility head were exchanged using the Freedom constrained liner system without revision of the cup and stem. As of this writing, 28 months after the revision surgery, no further dislocations have occurred. The implants are stable, and the patient has good range of motion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>Dual-mobility bearings are utilized to improve stability in both primary and revision total hip arthroplasties, but even if the dual mobility system is chosen, it sometimes fails to prevent postoperative dislocation. Although a relatively high failure rate has been reported in THA using the constrained liner system, this patient\u2019s clinical course suggests that the G7 Freedom constrained liner system can be an efficacious option for some patients with unstable hip joints who undergo THA using the dual mobility system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>A modern constrained liner system such as the G7 Freedom liner may provide an improved salvage solution for joint instability in dual mobility THA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Highlights<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2020.09.012","type":"journal-article","created":{"date-parts":[[2020,9,8]],"date-time":"2020-09-08T11:40:58Z","timestamp":1599565258000},"page":"94-99","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Dual mobility acetabular construct with freedom constrained liner for treatment of recurrent dislocations after total hip arthroplasty"],"prefix":"10.1097","volume":"75","author":[{"given":"Yuuki","family":"Onochi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiyokazu","family":"Fukui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ayumi","family":"Kaneuji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toru","family":"Ichiseki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xipeng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norio","family":"Kawahara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-22-20260114","doi-asserted-by":"crossref","first-page":"128","DOI":"10.2106\/JBJS.H.00155","article-title":"The epidemiology of revision total hip arthroplasty in the United States","volume":"91","author":"Bozic","year":"2009","journal-title":"J. Bone Joint Surg. Am"},{"key":"R2-22-20260114","doi-asserted-by":"crossref","first-page":"2088","DOI":"10.1016\/j.arth.2017.02.046","article-title":"Current epidemiology of revision total hip arthroplasty in the United States: national inpatient sample 2009 to 2013","volume":"32","author":"Gwam","year":"2017","journal-title":"J. Arthroplasty"},{"key":"R3-22-20260114","doi-asserted-by":"crossref","first-page":"3255","DOI":"10.1007\/s11999-010-1340-6","article-title":"Constrained liner in neurologic or cognitively impaired patients undergoing primary THA","volume":"468","author":"Hernigou","year":"2010","journal-title":"Clin. Orthop. Relat. Res"},{"key":"R4-22-20260114","doi-asserted-by":"crossref","first-page":"342","DOI":"10.3109\/17453674.2013.810518","article-title":"Effect of femoral head size on risk of revision for dislocation after total hip arthroplasty: a population-based analysis of 42,379 primary procedures from the Finnish Arthroplasty Register","volume":"84","author":"Kostensalo","year":"2013","journal-title":"Acta Orthop"},{"key":"R5-22-20260114","first-page":"2456","article-title":"Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty","volume":"87","author":"Berry","year":"2005","journal-title":"J. Bone Joint Surg. Am"},{"key":"R6-22-20260114","doi-asserted-by":"crossref","first-page":"217","DOI":"10.2106\/00004623-197860020-00014","article-title":"Dislocations after total hip-replacement arthroplasties","volume":"60","author":"Lewinnek","year":"1978","journal-title":"J. Bone Joint Surg. Am"},{"key":"R7-22-20260114","doi-asserted-by":"crossref","first-page":"2179","DOI":"10.2106\/00004623-200311000-00019","article-title":"The use of a constrained acetabular component to treat instability after total hip arthroplasty","volume":"85","author":"Shrader","year":"2003","journal-title":"J. Bone Joint Surg. Am"},{"key":"R8-22-20260114","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1054\/arth.2002.34823","article-title":"Success rate of modular component exchange for the treatment of an unstable total hip arthroplasty","volume":"17","author":"Earll","year":"2002","journal-title":"J. Arthroplasty"},{"key":"R9-22-20260114","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1007\/s002640050246","article-title":"Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study","volume":"22","author":"Farizon","year":"1998","journal-title":"Int. Orthop"},{"key":"R10-22-20260114","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1302\/0301-620X.99B1.BJJ-2016-0398.R1","article-title":"Dislocation following total hip arthroplasty using dual mobility acetabular components: a systematic review","volume":"99-B","author":"De Martino","year":"2017","journal-title":"Bone Joint J"},{"key":"R11-22-20260114","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ocl.2013.08.004","article-title":"Dual mobility in total hip arthroplasty","volume":"45","author":"Plummer","year":"2014","journal-title":"Orthop. Clin. North Am"},{"key":"R12-22-20260114","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.ijsu.2018.10.028","article-title":"The SCARE 2018 statement: updating consensus Surgical CAse REport (SCARE) guidelines","volume":"60","author":"Agha","year":"2018","journal-title":"Int. J. Surg"},{"key":"R13-22-20260114","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.arth.2016.01.063","article-title":"Should we think twice about psychiatric disease in total hip arthroplasty?","volume":"31","author":"Klement","year":"2016","journal-title":"J. Arthroplasty"},{"key":"R14-22-20260114","doi-asserted-by":"crossref","first-page":"1615","DOI":"10.1007\/s00402-014-2051-3","article-title":"Hip dislocations after 2,734 elective unilateral fast-track total hip arthroplasties: incidence, circumstances and predisposing factors","volume":"134","author":"J\u03c6rgensen","year":"2014","journal-title":"Arch. Orthop. Trauma Surg"},{"key":"R15-22-20260114","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1016\/S0883-5403(99)90219-X","article-title":"Risk factors for dislocation during the first 3 months after primary total hip replacement","volume":"14","author":"Woolson","year":"1999","journal-title":"J. Arthroplasty"},{"key":"R16-22-20260114","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1007\/s00264-005-0032-4","article-title":"Study of hip joint dislocation after total hip arthroplasty","volume":"30","author":"Masaoka","year":"2006","journal-title":"Int. Orthop"},{"key":"R17-22-20260114","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1016\/j.arth.2018.11.020","article-title":"Dual-mobility constructs in primary and revision total hip arthroplasty: a systematic review of comparative studies","volume":"34","author":"Reina","year":"2019","journal-title":"J. Arthroplasty"},{"key":"R18-22-20260114","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1016\/j.otsr.2019.12.019","article-title":"Can dual mobility cups prevent dislocation without increasing revision rates in primary total hip arthroplasty? A systematic review","volume":"106","author":"Jonker","year":"2020","journal-title":"Orthop. Traumatol. Surg. Res"},{"key":"R19-22-20260114","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1302\/0301-620X.101B1.BJJ-2018-0506.R1","article-title":"The use of dual-mobility bearings in patients at high risk of dislocation","volume":"101","author":"Jones","year":"2019","journal-title":"Bone Joint J"},{"key":"R20-22-20260114","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1007\/s00264-016-3368-z","article-title":"Dual mobility cups provide biomechanical advantages in situations at risk for dislocation: a finite element analysis","volume":"41","author":"Terrier","year":"2017","journal-title":"Int. Orthop"},{"key":"R21-22-20260114","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1302\/0301-620X.100B1.BJJ-2017-0462.R1","article-title":"Outcomes of dual mobility components in total hip arthroplasty: a systematic review of the literature","volume":"100-B","author":"Darrith","year":"2018","journal-title":"Bone Joint J"},{"key":"R22-22-20260114","doi-asserted-by":"crossref","first-page":"2704","DOI":"10.1016\/j.arth.2019.06.051","article-title":"Ten- to 16-year results of a modern cementless dual-mobility acetabular implant in primary total hip arthroplasty","volume":"34","author":"Gaillard","year":"2019","journal-title":"J. Arthroplasty"},{"key":"R23-22-20260114","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1080\/17453674.2018.1542210","article-title":"Dual mobility cups in primary total hip arthroplasties: trend over time in use, patient characteristics, and mid-term revision in 3,038 cases in the Dutch Arthroplasty Register (2007\u20132016)","volume":"90","author":"Bloemheuvel","year":"2019","journal-title":"Acta Orthop"},{"key":"R24-22-20260114","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1007\/s00264-016-3328-7","article-title":"Dual-mobility arthroplasty failure: a rationale review of causes and technical considerations for revision","volume":"41","author":"Hernigou","year":"2017","journal-title":"Int. Orthop"},{"key":"R25-22-20260114","doi-asserted-by":"crossref","first-page":"2793","DOI":"10.1016\/j.arth.2019.06.003","article-title":"High rate of early intraprosthetic dislocations of dual mobility implants: a single surgeon series of primary and revision total hip replacements","volume":"34","author":"Addona","year":"2019","journal-title":"J. Arthroplasty"},{"key":"R26-22-20260114","doi-asserted-by":"crossref","first-page":"3883","DOI":"10.1007\/s11999-013-2858-1","article-title":"Acetabular liner with focal constraint to prevent dislocation after THA","volume":"471","author":"Munro","year":"2013","journal-title":"Clin. Orthop. Relat. Res"},{"key":"R27-22-20260114","doi-asserted-by":"crossref","first-page":"1963","DOI":"10.1016\/j.arth.2016.02.021","article-title":"High failure rate of modular exchange with a specific design of a constrained liner in high-risk patients undergoing revision total hip arthroplasty","volume":"31","author":"Chalmers","year":"2016","journal-title":"J. Arthroplasty"},{"key":"R28-22-20260114","doi-asserted-by":"crossref","first-page":"2179","DOI":"10.2106\/00004623-200311000-00019","article-title":"The use of a constrained acetabular component to treat instability after total hip arthroplasty","volume":"85","author":"Shrader","year":"2003","journal-title":"J. Bone Joint Surg. Am"},{"key":"R29-22-20260114","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1054\/arth.2003.50090","article-title":"The use of a constrained acetabular component for recurrent dislocation","volume":"18","author":"Shapiro","year":"2003","journal-title":"J. Arthroplasty"},{"key":"R30-22-20260114","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.arth.2005.05.005","article-title":"High failure rate of a constrained acetabular liner in revision total hip arthroplasty","volume":"20","author":"Della Valle","year":"2005","journal-title":"J. Arthroplasty"},{"key":"R31-22-20260114","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.arth.2005.06.001","article-title":"The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty examining the successes and failures","volume":"20","author":"Berend","year":"2005","journal-title":"J. Arthroplasty"},{"key":"R32-22-20260114","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1097\/01.blo.0000150276.98701.95","article-title":"Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: a review of our experience","volume":"429","author":"Callaghan","year":"2004","journal-title":"Clin. Orthop. Relat. Res"},{"key":"R33-22-20260114","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/S0883-5403(03)00295-X","article-title":"Use of constrained acetabular components for hip instability: an average 10-year follow-up study","volume":"18","author":"Bremner","year":"2003","journal-title":"J. Arthroplasty"},{"key":"R34-22-20260114","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1177\/1457496916660035","article-title":"Freedom constrained liner for the treatment and prevention of dislocation in total hip arthroplasty","volume":"106","author":"Karvonen","year":"2017","journal-title":"Scand. J. Surg"},{"key":"R35-22-20260114","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.arth.2019.09.049","article-title":"Mid-term survivorship of a novel constrained acetabular device","volume":"35","author":"Crawford","year":"2020","journal-title":"J. Arthroplasty"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261220306842?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261220306842?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2020.09.012","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T13:50:52Z","timestamp":1768398652000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2020.09.012"}},"subtitle":["A case report and literature review"],"short-title":[],"issued":{"date-parts":[[2020,1]]},"references-count":35,"journal-issue":{"issue":"C","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2020.09.012","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2020,1]]}}}