{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T00:20:02Z","timestamp":1768436402168,"version":"3.49.0"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"C","license":[{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,9,17]],"date-time":"2020-09-17T00:00:00Z","timestamp":1600300800000},"content-version":"vor","delay-in-days":260,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Dislodgment of nasopharyngeal temperature probes and\/or unretrieved device fragments (UDFs) or gossypibome at a patient\u2019s hypopharynx is rare complication after orthognathic surgery that may occur as a result of surgical manipulation or may be a consequence of factors related to the insertion and handling of the probe after extubation. However, the exact mechanism of this complication is unknown. To the best of our knowledge, this is the 1st reported case of a missing temperature probe after orthognathic surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation<\/jats:title>\n                    <jats:p>We report the case of a patient who suffered from dislodgment of a 12-cm temperature probe after orthognathic surgery. The surgery was uneventful. At the end of the surgery, the probe was believed to have been completely removed from the nasal cavity. The nasopharyngeal cavity was visually inspected while the patient was still under anaesthesia and the trachea was still intubated. Extubation was successful, and the patient was moved to the recovery area. The patient was discharged from the hospital one day after resuming an oral fluid diet. At the follow-up visit on the 4th postoperative day, the patient presented with mild symptoms of a sore throat and cough. At the follow-up visit in the 3rd postoperative week, the patient reported one episode of vomiting and severe coughing, and the patient ultimately retrieved the 12-cm temperature probe from her mouth.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>After conducting a systematic literature review, we discuss surgical cases involving UDFs or gossypiboma. We also describe changes in our clinical practice after this event, and we envision that these modifications will have a positive influence on patient care. We believe that alternative routes for inserting temperature probes with covers would be suitable for orthognathic surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Vigilance should be maintained during patient extubation by both teams (surgeons and anaesthetists) to assure that part of the probe always remains visible outside the oral\/nasal cavity as well as complete removal of the device to avoid this life-threating complication.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Highlights<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2020.09.117","type":"journal-article","created":{"date-parts":[[2020,9,23]],"date-time":"2020-09-23T12:32:27Z","timestamp":1600864347000},"page":"429-432","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Gossypiboma during orthognathic surgery"],"prefix":"10.1097","volume":"75","author":[{"given":"Saleh Zaid","family":"Alshehri","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammed Ghazi","family":"Alkindi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Osama A.","family":"Ibraheim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Razan A.","family":"Ababtain","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Randa","family":"Alfotawi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-97-20260114","doi-asserted-by":"crossref","first-page":"1678","DOI":"10.1016\/j.joms.2011.05.010","article-title":"Unusual and rare complications of orthognathic surgery: a literature review","volume":"70","author":"Steel","year":"2012","journal-title":"J. Oral Maxillofac. Surg"},{"key":"R2-97-20260114","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1097\/00006534-199511000-00009","article-title":"Unusual complications of the Le Fort I osteotomy","volume":"96","author":"Bendor-Samuel","year":"1995","journal-title":"Plast. Reconstr. Surg"},{"key":"R3-97-20260114","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1111\/j.1442-2050.2009.00968.x","article-title":"Entrapment of a nasopharyngeal temperature probe: an unusual complication during an apparently uneventful elective revision laparoscopic Nissen fundoplication","volume":"23","author":"Wass","year":"2010","journal-title":"Dis. Esophagus"},{"key":"R4-97-20260114","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1007\/s11845-008-0197-0","article-title":"Gossypiboma: a case report and review of the literature","volume":"177","author":"Kiernan","year":"2008","journal-title":"Ir. J. Med. Sci"},{"key":"R5-97-20260114","first-page":"709","article-title":"MR imaging findings of paravertebral gossypiboma","volume":"28","author":"Kim","year":"2007","journal-title":"AJNR Am. J. Neuroradiol"},{"key":"R7-97-20260114","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/j.coms.2014.08.008","article-title":"Complications in orthognathic surgery: a report of 1,000 cases","volume":"26","author":"Robl","year":"2014","journal-title":"Oral Maxillofac. Surg. Clin. N. Am"},{"key":"R8-97-20260114","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.ijsu.2018.10.028","article-title":"The SCARE 2018 statement: updating Consensus Surgical CAse REport (SCARE) guidelines","volume":"60","author":"Agha","year":"2018","journal-title":"Int. J. Surg"},{"key":"R9-97-20260114","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1258\/0022215001905887","article-title":"Oropharyngeal foreign body","volume":"114","author":"Mishra","year":"2000","journal-title":"J. Laryngol. Otol"},{"key":"R10-97-20260114","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/S0377-1237(04)80020-0","article-title":"Retropharyngeal foreign","volume":"60","author":"Mehta","year":"2004","journal-title":"Body Med J. Armed Forces India"},{"key":"R11-97-20260114","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1007\/BF03047972","article-title":"Intramural migrating foreign body oesophagus","volume":"47","author":"Ramdas","year":"1995","journal-title":"Ind. J. Laryngol. Otol. Head Neck Surg"},{"key":"R12-97-20260114","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1016\/S0140-6736(95)90584-7","article-title":"Pharyngeal sensation and gag reflex in health subjects","volume":"345","author":"Ae","year":"1995","journal-title":"Lancet"},{"key":"R13-97-20260114","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1016\/j.jclinane.2006.05.012","article-title":"Potential aspiration hazard when using a nasopharyngeal temperature probe with disposable cover","volume":"18","author":"Kumar","year":"2006","journal-title":"J. Clin. Anesth"},{"key":"R14-97-20260114","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1053\/j.jvca.2003.10.030","article-title":"Massive epistaxis after nasopharyngeal temperature probe insertion after cardiac surgery","volume":"18","author":"Sinha","year":"2004","journal-title":"J. Cardiothorac. Vasc. Anesth"},{"key":"R15-97-20260114","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1213\/ANE.0000000000000361","article-title":"Optimal nasopharyngeal temperature probe placement","volume":"119","author":"Lee","year":"2014","journal-title":"Anesth. Analg"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261220307902?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261220307902?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2020.09.117","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T13:48:40Z","timestamp":1768398520000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2020.09.117"}},"subtitle":["A case report"],"short-title":[],"issued":{"date-parts":[[2020,1]]},"references-count":14,"journal-issue":{"issue":"C","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2020.09.117","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2020,1]]}}}