{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T23:35:08Z","timestamp":1768433708866,"version":"3.49.0"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"C","license":[{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,10,27]],"date-time":"2020-10-27T00:00:00Z","timestamp":1603756800000},"content-version":"vor","delay-in-days":300,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Pedicle screws are durable and safe instruments frequently used to treat vertebra injuries and deformities. There is also a possibility of medulla spinalis and visceral organ injury when the pedicle screws are delivered in unsuitable positions or dimensions. In this case, the authors want to draw attention to one of the visceral organ injuries during the thoracic pedicle screw placement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Presentation of case<\/jats:title>\n                    <jats:p>A 31 years old man underwent posterior instrumentation and fusion for T4 vertebra fractures. The patient was not symptomatic in the postoperative period. Tracheal pressure was observed at the 3rd thoracic vertebra level on the second day after the operation. No complications were encountered in the 3-year follow-up of the patient, who did not accept a second surgery recommended for screw replacement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>During surgery for thoracic vertebral fractures, the shoulder joint makes it difficult to imagine as the shoulder bones enter the field of view. Therefore, the number of misplaced screws increases. Moreover, it increases the risk of internal organ injury.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The use of navigation systems or cannulated pedicle screws to treat thoracic vertebral fractures reduces internal organ injuries.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Highlights<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2020.10.120","type":"journal-article","created":{"date-parts":[[2020,11,2]],"date-time":"2020-11-02T00:59:35Z","timestamp":1604278775000},"page":"225-228","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Is it an asymptomatic tracheal injury or misdiagnosis in treatment of vertebral fracture"],"prefix":"10.1097","volume":"77","author":[{"given":"Sinan","family":"Y\u0131lar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Serdar","family":"Toy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-53-20260114","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1097\/00005131-200607000-00012","article-title":"Esophageal injury from thoracic pedicle screw placement in a polytrauma patient: a case report and literature review","volume":"20","author":"O\u2019Brien","year":"2006","journal-title":"J. Orthop. Trauma"},{"key":"R2-53-20260114","doi-asserted-by":"crossref","first-page":"1553","DOI":"10.1097\/00007632-199707150-00002","article-title":"Anatomic relations of the thoracic pedicle to the adjacent neural structures","volume":"22","author":"Ebraheim","year":"1997","journal-title":"Spine"},{"key":"R4-53-20260114","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1007\/s00402-004-0654-9","article-title":"Late esophageal perforation complicating anterior cervical plate fixation in ankylosing spondylitis: a case report and review of the literature","volume":"124","author":"Zdichavsky","year":"2004","journal-title":"Arch. Orthop. Trauma Surg"},{"key":"R5-53-20260114","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1097\/BPO.0000000000000700","article-title":"Esophageal perforation caused by a posterior pedicle screw: a case report","volume":"37","author":"Sariyilmaz","year":"2017","journal-title":"J. Pediatr. Orthop"},{"key":"R6-53-20260114","doi-asserted-by":"crossref","first-page":"2679","DOI":"10.1097\/BRS.0b013e31815a7f13","article-title":"Computed tomography evaluation of pedicle screws placed in the pediatric deformed spine over an 8-year period","volume":"32","author":"Lehman","year":"2007","journal-title":"Spine"},{"key":"R7-53-20260114","doi-asserted-by":"crossref","first-page":"1892","DOI":"10.1007\/s00586-009-1065-y","article-title":"Evaluation of thoracic pedicle screw placement in adolescent idiopathic scoliosis","volume":"18","author":"\u015earlak","year":"2009","journal-title":"Eur. Spine J"},{"key":"R9-53-20260114","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.ijsu.2018.10.028","article-title":"The SCARE 2018 statement: updating consensus Surgical CAse REport (SCARE) guidelines","volume":"60","author":"Agha","year":"2018","journal-title":"Int. J. Surg"},{"key":"R10-53-20260114","doi-asserted-by":"crossref","first-page":"2951","DOI":"10.1007\/s00586-017-5266-5","article-title":"Accuracy of cannulated pedicle screw versus conventional pedicle screw for extra-pedicular screw placement in dysplastic pedicles without cancellous channel in adolescent idiopathic scoliosis: a computerized tomography (CT) analysis","volume":"26","author":"Lee","year":"2017","journal-title":"Eur. Spine J"},{"key":"R11-53-20260114","doi-asserted-by":"crossref","first-page":"E64","DOI":"10.1097\/BSD.0b013e3182a357ad","article-title":"Reliability and usefulness of intraoperative 3-dimensional imaging by mobile C-arm with flat-panel detector","volume":"30","author":"Fujimori","year":"2017","journal-title":"Clin. Spine Surg"},{"key":"R12-53-20260114","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1007\/s10143-015-0679-2","article-title":"Computer navigation versus fluoroscopy-guided navigation for thoracic pedicle screw placement: a meta-analysis","volume":"39","author":"Meng","year":"2016","journal-title":"Neurosurg. Rev"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261220309986?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261220309986?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2020.10.120","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T13:09:15Z","timestamp":1768396155000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2020.10.120"}},"subtitle":["A case report"],"short-title":[],"issued":{"date-parts":[[2020,1]]},"references-count":10,"journal-issue":{"issue":"C","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2020.10.120","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2020,1]]}}}