{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T00:36:30Z","timestamp":1768437390723,"version":"3.49.0"},"reference-count":9,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"C","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,12,16]],"date-time":"2020-12-16T00:00:00Z","timestamp":1608076800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Pancreatic fluid collections are a common complication of acute pancreatitis. They are classified as acute peripancreatic fluid collections and pancreatic pseudocysts. There has been an increase in the use of endoscopic ultrasound-guided drainage stents for management of these collections. As a result, complications such as stent migration are becoming more prevalent.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Presentation of case<\/jats:title>\n                    <jats:p>A 47-year-old male presented to the emergency department with upper abdominal pain, nausea and vomiting, and intermittent fevers. The patient had a known history of a pancreatic pseudocyst. He had undergone an endoscopic cyst-gastrostomy and placement of an AXIOS and Compass stents for drainage prior to the current presentation. The patient was investigated with a computed tomography (CT) scan that demonstrated acute pancreatitis, and migration of his AXIOS\/Compass stent complex into the transverse colon. The patient was managed conservatively, and ultimately passed the stent through his bowel motions without issue. Follow up abdominal x-ray confirmed the passage of the stent.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>Stent migration is a recognised complication of stent placement but is infrequently described for lumen-apposing metal stents like the AXIOS stent. The AXIOS stent has a dumbbell configuration designed to reduce the rate of migration compared to the original double-pigtail plastic stents. Despite this, stent migration still occurs, as in this case.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Complications of AXIOS stents can also include migration of the stent despite their specific design to prevent this. Conservative management is feasible rather than endoscopic retrieval and can be considered if there are no complicating features.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Highlights<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2020.12.053","type":"journal-article","created":{"date-parts":[[2020,12,25]],"date-time":"2020-12-25T09:44:10Z","timestamp":1608889450000},"page":"247-249","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Migration of an AXIOS stent complex into the colon \u2013 A case report"],"prefix":"10.1097","volume":"78","author":[{"given":"Steven","family":"Tran","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eu Nice","family":"Neo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-55-20260114","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1136\/gutjnl-2012-302779","article-title":"Classification of acute pancreatitis\u20132012: revision of the Atlanta classification and definitions by international consensus","volume":"62","author":"Banks","year":"2013","journal-title":"Gut"},{"key":"R2-55-20260114","doi-asserted-by":"crossref","first-page":"117","DOI":"10.5946\/ce.2017.045","article-title":"Endoscopic ultrasound-guided management of pancreatic fluid collections: update and review of the literature","volume":"50","author":"Alali","year":"2017","journal-title":"Clin. Endosc"},{"key":"R4-55-20260114","first-page":"168","article-title":"Endoscopic ultrasound-guided placement of AXIOS stent for drainage of pancreatic fluid collections","volume":"29","author":"Patil","year":"2016","journal-title":"Ann. Gastroenterol"},{"key":"R5-55-20260114","doi-asserted-by":"crossref","first-page":"1","DOI":"10.14309\/crj.0000000000000033","article-title":"Spontaneous closure of a large transmural gastric defect after removal of a migrated AXIOS stent","volume":"6","author":"Alshati","year":"2019","journal-title":"ACG Case Rep. J"},{"key":"R6-55-20260114","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1016\/j.gie.2011.10.020","article-title":"Clinical evaluation of a novel lumen-apposing metal stent for endosonography-guided pancreatic pseudocyst and gallbladder drainage (with videos)","volume":"75","author":"Itoi","year":"2012","journal-title":"Gastrointest. Endosc"},{"key":"R7-55-20260114","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1016\/j.gie.2015.04.006","article-title":"EUS-guided drainage of pancreatic fluid collections using a novel lumen-apposing metal stent on an electrocautery-enhanced delivery system: a large retrospective study (with video)","volume":"82","author":"Rinninella","year":"2015","journal-title":"Gastrointest. Endosc"},{"key":"R8-55-20260114","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1016\/j.cgh.2014.09.047","article-title":"Safety and efficacy of endoscopic ultrasound-guided drainage of pancreatic fluid collections with lumen-apposing covered self-expanding metal stents","volume":"13","author":"Shah","year":"2015","journal-title":"Clin. Gastroenterol. Hepatol"},{"key":"R9-55-20260114","doi-asserted-by":"crossref","first-page":"e73","DOI":"10.14309\/crj.2017.73","article-title":"Rare esophageal migration of AXIOS stent used for walled-off pancreatic necrosis drainage","volume":"4","author":"Abdel-Aziz","year":"2017","journal-title":"ACG Case Rep. J"},{"key":"R10-55-20260114","doi-asserted-by":"crossref","first-page":"e14","DOI":"10.14309\/crj.2018.14","article-title":"Migration of a lumen-apposing metal stent into the colon","volume":"5","author":"Mahmood","year":"2018","journal-title":"ACG Case Rep. J"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261220312438?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261220312438?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2020.12.053","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T13:50:27Z","timestamp":1768398627000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2020.12.053"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":9,"journal-issue":{"issue":"C","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2020.12.053","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}