{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T17:09:59Z","timestamp":1775322599805,"version":"3.50.1"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"C","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,12,22]],"date-time":"2020-12-22T00:00:00Z","timestamp":1608595200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Abdominal surgery uses various energy devices for vessel sealing, tissue dissection, and detachment. Currently, Acrosurg Revo\u00ae (Nikkiso Co., Ltd., Tokyo, Japan), a novel energy device using microwaves, has been developed for use in laparoscopic surgery. This report describes the early clinical experience of using this device in two cases of laparoscopic surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Presentation of case<\/jats:title>\n                    <jats:p>Case 1 was of a 64-year-old woman who underwent laparoscopic abdominal incisional hernia repair. Case 2 was of a 56-year-old man with a diagnosis of ascending and sigmoid colon cancer who underwent laparoscopic right hemicolectomy and sigmoid colectomy with D3 dissection. Each surgery was completed using Acrosurg Revo\u00ae and an endoscopic electrosurgical unit. The postoperative course was uneventful, and both patients were discharged from the hospital without any complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>With this new and novel device, vessel sealing, hemostasis, coagulation, tissue dissection, and detachment were all possible. Notably, there was no spark or mist that hindered the surgical field of view. Furthermore, because microwave coagulation did not result in tissue carbonization, there was a considerable decrease in device tip contamination.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The Acrosurg Revo\u00ae may be a useful energy device for laparoscopic surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Highlights<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2020.12.063","type":"journal-article","created":{"date-parts":[[2020,12,24]],"date-time":"2020-12-24T22:54:51Z","timestamp":1608850491000},"page":"375-377","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Early experience with a new integrated microwave surgical device, Acrosurg Revo\u00ae, for laparoscopic surgery"],"prefix":"10.1097","volume":"78","author":[{"given":"Yoshitaka","family":"Terada","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroya","family":"Akabori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyuki","family":"Ohta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yusuke","family":"Nishina","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eji","family":"Mekata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R3-86-20260114","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2147\/MDER.S113262","article-title":"Laparoscopic ultrasonic dissectors: technology update by a review of literature","volume":"12","author":"Devassy","year":"2018","journal-title":"Med. Devices"},{"key":"R4-86-20260114","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1007\/DCR.0b013e3181a0a70a","article-title":"Electrothermal bipolar vessel sealing system vs. harmonic scalpel in colorectal laparoscopic surgery: a prospective, randomized study","volume":"52","author":"Rimonda","year":"2009","journal-title":"Dis. Colon Rectum"},{"key":"R5-86-20260114","first-page":"571","article-title":"Application of a microwave tissue coagulator to hepatic surgery the hemostatic effects on spontaneous rupture of hepatoma and tumor necrosis","volume":"50","author":"Tabuse","year":"1981","journal-title":"Nihon Geka Hokan"},{"key":"R6-86-20260114","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/S1015-9584(09)60282-7","article-title":"Rapid microwave ablation of large hepatocellular carcinoma in a high-risk patient","volume":"28","author":"Strickland","year":"2005","journal-title":"Asian J. Surg"},{"key":"R7-86-20260114","doi-asserted-by":"crossref","first-page":"2441","DOI":"10.1023\/A:1020539421508","article-title":"Enzyme histochemistry is useful to assess viability of tumor tissue after microwave coagulation therapy (MCT): metastatic adenocarcinoma treated by lateral segmentectomy after MCT","volume":"47","author":"Mukaisho","year":"2002","journal-title":"Dig. Dis. Sci"},{"key":"R8-86-20260114","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.amjsurg.2015.07.008","article-title":"Thermal tissue change induced by a microwave surgical instrument in a rat hepatectomy model","volume":"211","author":"Vinh","year":"2016","journal-title":"Am. J. Surg"},{"key":"R9-86-20260114","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.amjsurg.2012.07.048","article-title":"Utility of a microwave surgical instrument in sealing lymphatic vessels","volume":"206","author":"Takebayashi","year":"2013","journal-title":"Am. J. Surg"},{"key":"R10-86-20260114","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1007\/s00595-018-1662-7","article-title":"The invention of microwave surgical scissors for seamless coagulation and cutting","volume":"48","author":"Tani","year":"2018","journal-title":"Surg. Today"},{"key":"R11-86-20260114","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/j.asjsur.2018.02.004","article-title":"Early experience with a new integrated microwave surgical device, Acrosurg.\u00ae for distal pancreatectomy","volume":"41","author":"Akabori","year":"2018","journal-title":"Asian J. Surg"},{"key":"R12-86-20260114","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1016\/j.asjsur.2019.05.004","article-title":"Feasibility of a new microwave energy based scissors device for hepatectomy","volume":"42","author":"Iida","year":"2019","journal-title":"Asian J. Surg"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261220312530?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261220312530?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2020.12.063","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T13:51:36Z","timestamp":1768398696000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2020.12.063"}},"subtitle":["A case series of two patients"],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":10,"journal-issue":{"issue":"C","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2020.12.063","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}