{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T23:54:52Z","timestamp":1768434892453,"version":"3.49.0"},"reference-count":41,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"C","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,2,19]],"date-time":"2021-02-19T00:00:00Z","timestamp":1613692800000},"content-version":"vor","delay-in-days":49,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction and importance<\/jats:title>\n                    <jats:p>Periprosthetic osteolysis (PPOL) is a common complication after total knee arthroplasty (TKA) and is most commonly caused by wear-induced particles.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation<\/jats:title>\n                    <jats:p>We report an unusual case of massive bilateral PPOL in the posterior flanges of the femur and patellae 4 years after bilateral uncemented TKA without patellar resurfacing in a 71-year old female. Bilateral staged revision surgery including polyethylene exchange and allograft morselized bone impaction was performed to treat the osteolytic lesions. There were no signs of implant malalignment, polyethylene wear or component loosening.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical discussion<\/jats:title>\n                    <jats:p>Several factors are associated with an increased risk on PPOL (e.g. polyethylene sterilization method, patient age, male gender). Surgical intervention in the context of massive PPOL should include replacement of a potential particle generator (most often polyethylene), correction of potential malalignment, treatment of bone defects and assessment of implant anchorage.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This report highlights the available evidence on clinical presentation, associated risk factors and preferred treatment strategy of massive osteolytic lesions after TKA according to available evidence.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Highlights<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2021.105678","type":"journal-article","created":{"date-parts":[[2021,2,26]],"date-time":"2021-02-26T13:11:42Z","timestamp":1614345102000},"page":"105678","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Bilateral massive osteolysis of uncertain origin after total knee arthroplasty"],"prefix":"10.1097","volume":"80","author":[{"given":"Rachid","family":"Rassir","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jorm M.","family":"Nellensteijn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rachid","family":"Saouti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter A.","family":"Nolte","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-88-20260114","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.5435\/00124635-200800001-00003","article-title":"How prevalent are implant wear and osteolysis, and how has the scope of osteolysis changed since 2000?","volume":"16","author":"Marshall","year":"2008","journal-title":"J. Am. Acad. Orthop. Surg"},{"key":"R2-88-20260114","doi-asserted-by":"crossref","first-page":"8046","DOI":"10.1016\/j.actbio.2013.05.005","article-title":"Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms","volume":"9","author":"Gallo","year":"2013","journal-title":"Acta Biomater"},{"key":"R4-88-20260114","doi-asserted-by":"crossref","first-page":"26","DOI":"10.5301\/hipint.5000413","article-title":"Periprosthetic femoral bone loss in total hip arthroplasty: systematic analysis of the effect of stem design","volume":"27","author":"Knutsen","year":"2017","journal-title":"Hip Int"},{"key":"R6-88-20260114","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.bonr.2017.07.003","article-title":"Mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic loosening","volume":"7","author":"Amirhosseini","year":"2017","journal-title":"Bone Rep"},{"key":"R7-88-20260114","doi-asserted-by":"crossref","first-page":"361","DOI":"10.3109\/17453679408995473","article-title":"Theories of wear and loosening in hip prostheses: wear-induced loosening vs loosening-induced wear\u2013a review","volume":"65","author":"Mj\u00f6berg B","year":"1994","journal-title":"Acta Orthop. Scand"},{"key":"R8-88-20260114","first-page":"261","article-title":"Recognizing and identifying osteolysis around total knee arthroplasty","volume":"53","author":"Berry","year":"2004","journal-title":"Instr. Course Lect"},{"key":"R9-88-20260114","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1055\/s-2008-1044606","article-title":"Patellar changes during long-term observations on the Blauth knee joint endoprosthesis","volume":"122","author":"Hassenpflug","year":"1984","journal-title":"Z. Orthop. Ihre Grenzgeb"},{"key":"R10-88-20260114","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/s00402-007-0292-0","article-title":"The disappearing Patella\": an unusual sequel following total knee replacement","volume":"128","author":"Thomas","year":"2008","journal-title":"Arch. Orthop. Trauma Surg"},{"key":"R11-88-20260114","doi-asserted-by":"crossref","first-page":"2262","DOI":"10.1007\/s11999-011-1872-4","article-title":"History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene","volume":"469","author":"Kurtz","year":"2011","journal-title":"Clin. Orthop. Relat. Res"},{"key":"R12-88-20260114","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.ijsu.2020.10.034","article-title":"The SCARE 2020 guideline: updating consensus Surgical CAse REport (SCARE) guidelines","volume":"84","author":"Agha","year":"2020","journal-title":"Int. J. Surg"},{"key":"R13-88-20260114","first-page":"227","article-title":"The management of bone defects in revision total knee arthroplasty","volume":"46","author":"Engh","year":"1997","journal-title":"Instr. Course Lect"},{"key":"R14-88-20260114","doi-asserted-by":"crossref","first-page":"575","DOI":"10.2106\/00004623-198365050-00001","article-title":"The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis","volume":"65","author":"Goldring","year":"1983","journal-title":"JBJS"},{"key":"R15-88-20260114","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1097\/00003086-198807000-00032","article-title":"The effects of bulk versus particulate polymethylmethacrylate on bone","volume":"232","author":"Goodman","year":"1988","journal-title":"Clin. Orthop. Relat. Res"},{"key":"R16-88-20260114","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/S0883-5403(88)80027-5","article-title":"Femoral lysis after cemented hip arthroplasty","volume":"3","author":"Huddleston","year":"1988","journal-title":"J. Arthroplasty"},{"key":"R17-88-20260114","doi-asserted-by":"crossref","first-page":"966","DOI":"10.1302\/0301-620X.72B6.2246299","article-title":"Bone lysis in well-fixed cemented femoral components","volume":"72","author":"Maloney","year":"1990","journal-title":"J. Bone Joint Surg. Br"},{"key":"R18-88-20260114","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1302\/0301-620X.67B2.3980529","article-title":"Osteolytic changes in the upper femoral shaft following porous-coated hip replacement","volume":"67","author":"Brown","year":"1985","journal-title":"J. Bone Joint Surg. Br"},{"key":"R19-88-20260114","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.2106\/00004623-199072070-00011","article-title":"Endosteal erosion in association with stable uncemented femoral components","volume":"72","author":"Maloney","year":"1990","journal-title":"J. Bone Joint Surg. Am"},{"key":"R20-88-20260114","doi-asserted-by":"crossref","first-page":"980","DOI":"10.1302\/0301-620X.72B6.2246301","article-title":"Aggressive granulomatous lesions in cementless total hip arthroplasty","volume":"72","author":"Santavirta","year":"1990","journal-title":"J. Bone Joint Surg. Br"},{"key":"R21-88-20260114","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1016\/j.arth.2013.07.024","article-title":"Why are total knee arthroplasties failing today\u2014has anything changed after 10 years?","volume":"29","author":"Sharkey","year":"2014","journal-title":"J. Arthroplasty"},{"key":"R22-88-20260114","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.jor.2019.02.004","article-title":"Calcium pyrophosphate deposition disease after total knee arthroplasty: comparison with periprosthetic joint infection","volume":"16","author":"Iwasaki","year":"2019","journal-title":"J. Orthop"},{"key":"R23-88-20260114","first-page":"412","article-title":"Evaluation of the anatomic patellar prosthesis in uncemented porous-coated total knee arthroplasty: seven-year results","volume":"24","author":"Kim","year":"1995","journal-title":"Am J. Orthop"},{"key":"R24-88-20260114","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1097\/00003086-199512000-00013","article-title":"Effect of component fixation method on osteolysis in total knee arthroplasty","volume":"321","author":"Ezzet","year":"1995","journal-title":"Clin. Orthop. Relat. Res"},{"key":"R25-88-20260114","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1097\/00003086-199512000-00014","article-title":"Effect of porous-coating configuration on tibial osteolysis after total knee arthroplasty","volume":"321","author":"Whiteside","year":"1995","journal-title":"Clin. Orthop. Relat. Res"},{"key":"R26-88-20260114","first-page":"243","article-title":"Epidemiology of osteolysis: backside implant wear","volume":"53","author":"Engh","year":"2004","journal-title":"Instr. Course Lect"},{"key":"R28-88-20260114","first-page":"2702","article-title":"Osteolysis after total knee arthroplasty: influence of tibial baseplate surface finish and sterilization of polyethylene insert. Findings at five to ten years postoperatively","volume":"87","author":"Collier","year":"2005","journal-title":"J. Bone Joint Surg. Am"},{"key":"R29-88-20260114","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1097\/BLO.0b013e3181591c62","article-title":"PFC knee replacement: osteolytic failures from extreme polyethylene degradation","volume":"464","author":"Casey","year":"2007","journal-title":"Clin. Orthop. Relat. Res"},{"key":"R30-88-20260114","doi-asserted-by":"crossref","first-page":"1863","DOI":"10.1007\/s00167-014-3088-0","article-title":"Factors affecting the osteolysis around the components after posterior-stabilized total knee replacement arthroplasty","volume":"23","author":"Kim","year":"2015","journal-title":"Knee Surg. Sports Traumatol. Arthrosc"},{"key":"R31-88-20260114","first-page":"431","article-title":"Mobile-bearing knee replacement: concepts and results","volume":"50","author":"Callaghan","year":"2001","journal-title":"Instr. Course Lect"},{"key":"R32-88-20260114","doi-asserted-by":"crossref","first-page":"2224","DOI":"10.2106\/00004623-200212000-00015","article-title":"Osteolysis in failed total knee arthroplasty: a comparison of mobile-bearing and fixed-bearing knees","volume":"84","author":"Huang","year":"2002","journal-title":"J. Bone Joint Surg. Am"},{"key":"R33-88-20260114","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/j.arth.2008.05.005","article-title":"Prevalence of osteolysis after simultaneous bilateral fixed- and mobile-bearing total knee arthroplasties in young patients","volume":"24","author":"Kim","year":"2009","journal-title":"J. Arthroplasty"},{"key":"R34-88-20260114","doi-asserted-by":"crossref","first-page":"3084","DOI":"10.1007\/s11999-010-1336-2","article-title":"Osteolysis in well-functioning fixed- and mobile-bearing TKAs in younger patients","volume":"468","author":"Kim","year":"2010","journal-title":"Clin. Orthop. Relat. Res"},{"key":"R35-88-20260114","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1007\/s11999-010-1557-4","article-title":"Wear damage in mobile-bearing TKA is as severe as that in fixed-bearing TKA","volume":"469","author":"Kelly","year":"2011","journal-title":"Clin. Orthop. Relat. Res"},{"key":"R36-88-20260114","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.arth.2003.08.005","article-title":"Underestimation of osteolysis in posterior stabilized total knee arthroplasty","volume":"19","author":"Nadaud","year":"2004","journal-title":"J. Arthroplasty"},{"key":"R37-88-20260114","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.arth.2005.09.005","article-title":"Magnetic resonance imaging to evaluate osteolysis around total knee arthroplasty","volume":"21","author":"Mosher","year":"2006","journal-title":"J. Arthroplasty"},{"key":"R38-88-20260114","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1055\/s-0030-1248116","article-title":"Use of multi-detector computed tomography for the detection of periprosthetic osteolysis in total knee arthroplasty","volume":"19","author":"Reish","year":"2006","journal-title":"J. Knee Surg"},{"key":"R39-88-20260114","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1016\/j.arth.2005.10.017","article-title":"Magnetic resonance imaging with metal suppression for evaluation of periprosthetic osteolysis after total knee arthroplasty","volume":"21","author":"Vessely","year":"2006","journal-title":"J. Arthroplasty"},{"key":"R40-88-20260114","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/j.arth.2011.03.047","article-title":"Detection of periprosthetic osteolysis around total knee arthroplasties an in vitro study","volume":"27","author":"Zotti","year":"2012","journal-title":"J. Arthroplasty"},{"key":"R41-88-20260114","doi-asserted-by":"crossref","first-page":"2280","DOI":"10.1016\/j.arth.2014.05.013","article-title":"Detection of small periprosthetic bone defects after total knee arthroplasty","volume":"29","author":"Minoda","year":"2014","journal-title":"J. Arthroplasty"},{"key":"R42-88-20260114","doi-asserted-by":"crossref","first-page":"S26","DOI":"10.5435\/00124635-200800001-00007","article-title":"What is the outcome of treatment for osteolysis?","volume":"16","author":"Maloney","year":"2008","journal-title":"J. Am. Acad. Orthop. Surg"},{"key":"R43-88-20260114","first-page":"98","article-title":"Management of metaphyseal bone loss in revision knee arthroplasty","volume":"88","author":"Mancuso","year":"2017","journal-title":"Acta Biomed"},{"key":"R44-88-20260114","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1007\/s00264-013-2262-1","article-title":"Bone loss management in total knee revision surgery","volume":"38","author":"Panegrossi","year":"2014","journal-title":"Int. Orthop"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261221001784?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261221001784?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2021.105678","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T13:37:35Z","timestamp":1768397855000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2021.105678"}},"subtitle":["A case report and review of literature"],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":41,"journal-issue":{"issue":"C","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2021.105678","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}