{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T00:36:04Z","timestamp":1768437364776,"version":"3.49.0"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"C","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,9,12]],"date-time":"2021-09-12T00:00:00Z","timestamp":1631404800000},"content-version":"vor","delay-in-days":254,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction and importance<\/jats:title>\n                    <jats:p>Surgical treatment for clavicle injuries is indicated for displaced and shortened fractures. Osteosyntheses with plate fixation may present with complications in 6.3% to 8.5% of patients. Peri-implant clavicle fractures (PIF) are rare, and we have not found any previous cases in our literature search.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation<\/jats:title>\n                    <jats:p>A 25-year-old male with previously (six years earlier) surgically treated clavicle fracture presented with a peri-implant clavicle fracture requiring surgical treatment. The management involved overlaying an implant to fix the lateral clavicle fracture without removing the previous plate. Complete bone healing was observed without any further complication.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical discussion<\/jats:title>\n                    <jats:p>Despite the low rate of implant failure in clavicle fractures, this complication occurs mainly in elderly patients with poor bone quality. No PIF have been described in the literature prior to this. This case report demonstrates a young patient with good bone quality and previous fracture fixation presenting with PIF which has now shown complete bone healing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In this case, overlying an additional plate on the lateral clavicle portion without removing the previous plate increased the stability of the fracture. It demonstrates the value of overlaying plate osteosyntheses for patients with clavicle PIF.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Highlights<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2021.106411","type":"journal-article","created":{"date-parts":[[2021,9,15]],"date-time":"2021-09-15T12:05:11Z","timestamp":1631707511000},"page":"106411","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Peri-implant distal clavicle fracture"],"prefix":"10.1097","volume":"87","author":[{"given":"Guilherme Vieira","family":"Lima","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nataniel Sousa","family":"Santos Filho","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C\u00e9zar Augusto","family":"Pimentel Furlan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joel","family":"Murachovsky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vitor","family":"La Banca","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roberto Yukio","family":"Ikemoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-33-20260114","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1097\/00003086-199403000-00016","article-title":"The incidence of fractures of the clavicle","volume":"300","author":"Nordqvist","year":"1994","journal-title":"Clin. Orthop. Relat. Res"},{"key":"R2-33-20260114","first-page":"47","article-title":"Treatment of clavicle fractures","volume":"2","author":"Paladini","year":"2012","journal-title":"Transl. Med UniSa"},{"key":"R3-33-20260114","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1016\/j.injury.2017.01.040","article-title":"Van der heijden FH. construct failure after open reduction and plate fixation of displaced midshaft clavicular fractures","volume":"48","author":"Meeuwis","year":"2017","journal-title":"Injury"},{"key":"R4-33-20260114","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1097\/01.bot.0000172287.44278.ef","article-title":"Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the Evidence-Based Orthopaedic Trauma Working Group","volume":"19","author":"Zlowodzki","year":"2005","journal-title":"J. Orthop. Trauma"},{"key":"R5-33-20260114","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.otsr.2015.11.008","article-title":"Reconstruction plates for midshaft clavicular fractures: a retrospective cohort study","volume":"102","author":"Woltz","year":"2016","journal-title":"Orthop. Traumatol. Surg. Res"},{"key":"R6-33-20260114","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1186\/s13018-014-0055-x","article-title":"Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study","volume":"9","author":"Gilde","year":"2014","journal-title":"J. Orthop. Surg. Res"},{"key":"R7-33-20260114","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1007\/s11999-016-5113-8","article-title":"High irritation and removal rates after plate or nail fixation in patients with displaced midshaft clavicle fractures","volume":"475","author":"Hulsmans","year":"2017","journal-title":"Clin. Orthop. Relat. Res"},{"key":"R8-33-20260114","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1186\/s13018-019-1259-x","article-title":"Comparison of implant failure rates of different plates for midshaft clavicular fractures based on fracture classifications","volume":"14","author":"Chiu","year":"2019","journal-title":"J. Orthop. Surg. Res"},{"key":"R9-33-20260114","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.ijsu.2020.10.034","article-title":"The SCARE 2020 guideline: updating consensus Surgical CAse REport (SCARE) guidelines","volume":"84","author":"Agha","year":"2020","journal-title":"Int. J. Surg"},{"key":"R10-33-20260114","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1186\/s13256-019-2046-3","article-title":"Mechanical failure of plate breakage after open reduction and plate fixation of displaced midshaft clavicle fracture - a possible new risk factor: a case report","volume":"13","author":"Batash","year":"2019","journal-title":"J. Med. Case Rep"},{"key":"R11-33-20260114","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1186\/s13018-019-1516-z","article-title":"Risk factors for refracture after plate removal for midshaft clavicle fracture after bone union","volume":"14","author":"Tsai","year":"2019","journal-title":"J. Orthop. Surg. Res"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261221009135?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261221009135?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2021.106411","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T13:47:02Z","timestamp":1768398422000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2021.106411"}},"subtitle":["Case report (overlaying plate fixation Solution for peri-implant clavicle fractures)"],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":11,"journal-issue":{"issue":"C","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2021.106411","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}