{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T08:57:35Z","timestamp":1775897855720,"version":"3.50.1"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"C","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,11,4]],"date-time":"2021-11-04T00:00:00Z","timestamp":1635984000000},"content-version":"vor","delay-in-days":307,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction and importance<\/jats:title>\n                    <jats:p>Penile strangulation due to metallic objects in pediatric age groups is a rare urological emergency that warrant emergency management. Removal of metallic ring from strangulated penis poses a great challenge to urologist as it may require industrial gadgets. Multidisciplinary management involving psychiatrist is required. To the best of our knowledge, this is the first reported novel case of penile strangulation by a metallic nut in children in Tanzania. Furthermore, this case report shows that Industrial Manual Scissor metal (IMSMC) cutter offers a safe way of removing metallic nut from strangulated penis with few complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation<\/jats:title>\n                    <jats:p>We report a case report of penile strangulation in an 8 year-old boy by a metallic nut which stayed for 11 h prior to arriving at a tertiary hospital in Northern Tanzania. The reason for insertion of nut by a child was not clear.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical discussion<\/jats:title>\n                    <jats:p>On arrival to the hospital the child was clinically stable but in pain. Local examination revealed a metallic nut at proximal penis with grossly edematous penis. A diagnosis of penile strangulation by metallic nut was reached and the child was planned for emergency surgery to remove the metallic nut. The metallic nut was successful removed by IMSMC. This technique has been used in adult with success with few complications and therefore opted in our setting. The child was also diagnosed with oppositional defiant disorder.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Industrial Manual Scissor Metal cutter is a safe way of managing penile strangulation by a metallic nut in children.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Highlights<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2021.106581","type":"journal-article","created":{"date-parts":[[2021,11,10]],"date-time":"2021-11-10T11:53:33Z","timestamp":1636545213000},"page":"106581","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Penile strangulation by a metallic nut in an 8-year-old male"],"prefix":"10.1097","volume":"89","author":[{"given":"Orgeness Jasper","family":"Mbwambo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edward","family":"Kiattu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jasper","family":"Mbwambo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank","family":"Bright","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alfred K.","family":"Mteta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bartholomeo Nicholaus","family":"Ngowi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-24-20260114","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/s12301-020-00057-2","article-title":"Two cases of penile strangulation: varied presentations and vastly diferent outcomes","volume":"26","author":"Agrawal","year":"2020","journal-title":"Afr. J. Urol"},{"key":"R2-24-20260114","first-page":"214","article-title":"Penile strangulation with metallic objects in adults: 2 case reports and literature review","volume":"4","author":"Choudhary","year":"2014","journal-title":"Emerg. Med. (Los Angel"},{"key":"R3-24-20260114","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1111\/j.1464-410X.1991.tb15426.x","article-title":"Penile strangulation","volume":"68","author":"Bhat","year":"1991","journal-title":"Br. J. Urol"},{"key":"R4-24-20260114","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1016\/j.jpedsurg.2019.12.011","article-title":"Penile strangulation injury in children \u2014 Reconstructive procedure and outcome","volume":"55","author":"Qamar","year":"2020","journal-title":"J. Pediatr. Surg"},{"key":"R5-24-20260114","first-page":"e15659","article-title":"A rare case of penile strangulation managed by orthopedic jumbo cutter","volume":"13","author":"Laik","year":"2021","journal-title":"Cureus"},{"key":"R6-24-20260114","doi-asserted-by":"crossref","first-page":"138","DOI":"10.4081\/aiua.2014.2.138","article-title":"Treatment of penile strangulation by the rotating saw and 4- needle aspiration method: two case reports","volume":"86","author":"Talib","year":"2014","journal-title":"Arch. Ital. Urol. Androl"},{"key":"R7-24-20260114","doi-asserted-by":"crossref","first-page":"1747","DOI":"10.1111\/j.1743-6109.2008.00848.x","article-title":"Penile constriction devices: case report, review of the literature, and recommendations for extrication","volume":"5","author":"Silberstein","year":"2008","journal-title":"J. Sex. Med"},{"key":"R8-24-20260114","first-page":"0","article-title":"Genital self-mutilation case in high-level educated person","volume":"10","author":"Ilgi","year":"2016","journal-title":"Urol Case Rep"},{"key":"R9-24-20260114","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/j.jemermed.2008.06.034","article-title":"Safe emergency removal of a hardened steel penile constriction ring","volume":"37","author":"Peay","year":"2009","journal-title":"J. Emerg. Med"},{"key":"R10-24-20260114","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1016\/j.urology.2004.04.058","article-title":"Penile strangulation treated with the modified string method","volume":"64","author":"Noh","year":"2004","journal-title":"Urology"},{"key":"R11-24-20260114","doi-asserted-by":"crossref","first-page":"74","DOI":"10.4103\/0974-7796.198873","article-title":"Penile strangulation by iron metal ring: a novel and effective method of management","volume":"9","author":"Paonam","year":"2017","journal-title":"Urol. Ann"},{"key":"R12-24-20260114","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.ijsu.2020.10.034","article-title":"The SCARE 2020 Guideline: updating Consensus Surgical CAse REport (SCARE) guidelines,","volume":"84","author":"Agha","year":"2020","journal-title":"Int. J. Surg"},{"key":"R13-24-20260114","doi-asserted-by":"crossref","first-page":"07","DOI":"10.33545\/surgery.2017.v1.i1a.3","article-title":"Penile strangulation by metallic ring: a case report","volume":"1","author":"Kumar","year":"2017","journal-title":"Int. J. Surg. Sci"},{"key":"R14-24-20260114","first-page":"5216826","article-title":"Penile and scrotal strangulation due to metal rings: case reports and a review of the literature","volume":"2018","author":"Patel","year":"2018","journal-title":"Hindawi Case Rep. Surg"},{"key":"R15-24-20260114","doi-asserted-by":"crossref","first-page":"1747","DOI":"10.1111\/j.1743-6109.2008.00848.x","article-title":"Penile constriction devices: case report, review of the literature, and recommendations for extrication","volume":"5","author":"Silberstein","year":"2008","journal-title":"J. Sexual Med"},{"key":"R16-24-20260114","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1046\/j.1464-410X.1997.00204.x","article-title":"Penile constriction by foreign bodies: the use of a dental drill","volume":"79","author":"Huang","year":"1997","journal-title":"Br. J. Urol"},{"key":"R19-24-20260114","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/0090-4295(88)90313-5","article-title":"Adolescent males who insert genitourinary foreign bodies: is psychiatric referral required","volume":"32","author":"Kenney","year":"1988","journal-title":"Urology"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S221026122101083X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S221026122101083X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2021.106581","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T13:33:22Z","timestamp":1768397602000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2021.106581"}},"subtitle":["A rare case report of urological emergency"],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":17,"journal-issue":{"issue":"C","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2021.106581","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}