{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T04:17:56Z","timestamp":1790655476164,"version":"4.1.0"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"C","license":[{"start":{"date-parts":[[2023,11,1]],"date-time":"2023-11-01T00:00:00Z","timestamp":1698796800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,11,1]],"date-time":"2023-11-01T00:00:00Z","timestamp":1698796800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,10,8]],"date-time":"2023-10-08T00:00:00Z","timestamp":1696723200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,11]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction and importance:<\/jats:title>\n                    <jats:p>Open ulnar and radial shaft fractures refers to the simultaneous rupture and injury of the skin and subcutaneous soft tissue at the fracture, and is easy to cause wound infection, local soft tissue necrosis or osteomyelitis. The purpose of this paper is to observe the efficacy of external locking compression plate in the treatment of open fractures, so as to provide reference for clinical practice.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation:<\/jats:title>\n                    <jats:p>From January 2019 to January 2020, 11 patients with open ulnar or radial shaft fractures underwent surgery by a single surgeon. Physical examination, radiography, and functional scores were performed before surgery and the average follow-up was 14 months (range, 12 to16 months) after surgery. Clinical outcome scores were recorded. Six patients obtained excellent Anderson Scores, four of satisfactory and one of Unsatisfactory. No surgical complications, reoperations, nonunion and implant breakage in this series and the fractures can be healed from 6 to 12 months after the operation. All implant removal was requested for all cases.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical discussion:<\/jats:title>\n                    <jats:p>Open ulnar and radial shaft fractures refers to the simultaneous rupture and injury of the skin and subcutaneous soft tissue at the fracture, which can connect the fracture site with the outside environment, and is easy to cause wound infection, local soft tissue necrosis or osteomyelitis. The open fracture mostly involves adjacent joints. If it is not treated in time, it is easy to lead to complications such as infection and nonunion. The locking plate is named as \u201cinternal fixation\u201d, which means the internal fixation is placed in the soft tissue, and is similar to the external fixator. However, its biomechanical properties still need to be verified, the appropriate screw position and number need to be further defined, and there is a lack of clinical validation of large number of cases.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>In this study, locking compression plate externaI fixation for technology for the treatment of open ulnar and radial shaft fractures has the advantages of minimal trauma, simple operation, reliable fixation, fewer postoperative complications, and restored stability and function of forearm joints.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of evidence:<\/jats:title>\n                    <jats:p>Level IV, therapeutic case series.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Highlights<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2023.108943","type":"journal-article","created":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T21:18:22Z","timestamp":1697491102000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Clinical results of locking compression plate external fixation for open ulnar and radial shaft fractures"],"prefix":"10.1097","volume":"112","author":[{"given":"Kai","family":"Sun","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yufu","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-35-20260316","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1097\/01.bot.0000202997.45274.a1","article-title":"Treatment of distal tibial fractures without articular involvement:a systematic review of 1125 fractures","volume":"20","author":"Zelle,","year":"2006","journal-title":"J. Orthop. Trauma"},{"key":"R2-35-20260316","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1007\/s00264-007-0384-z","article-title":"Wound complication of minima llyinvasive plate osteosynthesis in distal tibial fractures","volume":"32","author":"Lau,","year":"2008","journal-title":"Int. Orthop"},{"key":"R3-35-20260316","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1302\/0301-620X.88B5.16875","article-title":"Incidence and aetiology of anterior knee pain after in tramedullary nailing of the femur and tibia","volume":"88","author":"Katsoulis,","year":"2006","journal-title":"J. Bone Joint Surg. (Br"},{"key":"R4-35-20260316","first-page":"614","article-title":"Using external and internal locking lates in a two-stage protocol for treatment of segmental tibial fractures","volume":"71","author":"Ma,","year":"2011","journal-title":"J. Trauma"},{"key":"R5-35-20260316","first-page":"190","article-title":"Staged external and internal lessinv","volume":"41","author":"Ma,","year":"2010","journal-title":"Injury"},{"key":"R6-35-20260316","doi-asserted-by":"crossref","first-page":"382","DOI":"10.3109\/17453674.2010.487244","article-title":"Staged external and internal locked plating for open distal tibial fractures","volume":"81","author":"Ma,","year":"2010","journal-title":"Acta Orthop"},{"key":"R7-35-20260316","doi-asserted-by":"crossref","first-page":"e454","DOI":"10.1097\/BOT.0000000000000377","article-title":"External fixation using a locking plate:a reliable way in treating distal tibial fractures","volume":"29","author":"Zhang,","year":"2015","journal-title":"J. Orthop. Trauma"},{"key":"R8-35-20260316","doi-asserted-by":"crossref","first-page":"60","DOI":"10.3109\/17453679108993094","article-title":"The AO-plate for external fixation in 12 cases","volume":"62","author":"Marti,","year":"1991","journal-title":"Acta Orthop. Scand"},{"key":"R9-35-20260316","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1016\/j.injury.2007.05.005","article-title":"The locking compression plate as an external fixator for bone transport in the treatment of a large distal tibial defect: a case report","volume":"38","author":"Appivat thakakul,","year":"2007","journal-title":"Injury"},{"key":"R10-35-20260316","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1007\/s00402-019-03237-0","article-title":"Early experience of lateral hinge fracture during medial opening-wedge high tibial osteotomy: incidence and clinical outcomes","volume":"140","author":"Song,","year":"2020","journal-title":"Arch. Orthop. Trauma Surg"},{"key":"R11-35-20260316","first-page":"641","article-title":"Application of damage control external fixator in the treatment of open middle and lower tibial fractures","volume":"34","author":"Li,","year":"2019","journal-title":"Zhongguo Gu Yu Guan Jie Sun Shang Za Zhi"},{"key":"R12-35-20260316","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1016\/j.knee.2019.10.027","article-title":"Lateral hinge fracture delays healing of the osteotomy gap in opening wedge high tibial osteotomy with a beta-tricalcium phosphate block","volume":"27","author":"Kumagai,","year":"2020","journal-title":"Knee"},{"key":"R13-35-20260316","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1055\/s-0030-1248022","article-title":"Lockmg plate technology: current concepts","volume":"20","author":"Greiwe,","year":"2007","journal-title":"J. Knee Surg"},{"key":"R14-35-20260316","doi-asserted-by":"crossref","first-page":"183","DOI":"10.5435\/00124635-200603000-00009","article-title":"The use of locking plates in fracture care","volume":"14","author":"Cantu,","year":"2006","journal-title":"J. Am. Acad. Orthop. Surg"},{"key":"R15-35-20260316","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1097\/00005131-200409000-00003","article-title":"Biomechanics of lock plates and screws","volume":"18","author":"Ego,","year":"2004","journal-title":"J. Orthop. Trauma"},{"key":"R16-35-20260316","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1097\/BOT.0b013e31818f8de4","article-title":"Supercutaneous plating: use of a locking compression plate as an external fixator","volume":"23","author":"Kloen,","year":"2009","journal-title":"J. Orthop. Trauma"},{"key":"R17-35-20260316","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1007\/s00402-013-1916-1","article-title":"Locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop","volume":"134","author":"Qiu,","year":"2014","journal-title":"Arch. Orthop. Trauma Surg"},{"key":"R18-35-20260316","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1097\/BOT.0000000000000377","article-title":"External fixation using a locking plate: a reliable way in treating distal tibial fractures","volume":"29","author":"Zhang,","year":"2015","journal-title":"J. Orthop. Trauma"},{"key":"R19-35-20260316","first-page":"614","article-title":"Using external and internal locking plates in a two - stage protocol for treatment of segmental tibial fractures","volume":"71","author":"Ma,","year":"2011","journal-title":"J. Trauma"},{"key":"R20-35-20260316","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1177\/107110079801901211","article-title":"Wound healing risk factors after open reduction and internal fixation of calcaneal fractures","volume":"19","author":"Abidi,","year":"1998","journal-title":"Foot Ankle Int"},{"key":"R21-35-20260316","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1177\/107110070102201102","article-title":"Morbidity associated with ORIF of intra-articular calcaneus fractures using a lateral approach","volume":"22","author":"Harvey,","year":"2001","journal-title":"Foot Ankle Int"},{"key":"R22-35-20260316","first-page":"225","article-title":"Use of the AO plate as external fixation","volume":"12","author":"Marti,","year":"1984","journal-title":"Z. Orthop. Ihre Grenzgeb"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261223010726?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261223010726?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2023.108943","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T10:01:31Z","timestamp":1773655291000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2023.108943"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11]]},"references-count":22,"journal-issue":{"issue":"C","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2023.108943","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2023,11]]}}}