{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T14:24:29Z","timestamp":1790173469946,"version":"4.1.0"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"C","license":[{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,3,8]],"date-time":"2024-03-08T00:00:00Z","timestamp":1709856000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction and importance:<\/jats:title>\n                    <jats:p>The Intrauterine Contraceptive Device (IUD), a widely used contraceptive since 1965, has demonstrated efficacy but is associated with complications such as bleeding, pain, and rare occurrences of perforation. This case report details an IUD migration into the peritoneal cavity, leading to acute appendicitis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation:<\/jats:title>\n                    <jats:p>A 33-year-old woman, with a history of IUD insertion 16 months prior, presented with pelvic pain. Gynecological examination and computed tomography, revealed the IUD intraperitoneal migration. The patient underwent laparoscopic extraction of the IUD which was embedded in the appendix and appendectomy, with an uneventful recovery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical discussion:<\/jats:title>\n                    <jats:p>This case emphasizes the complexity of IUD migration and its rare association with acute appendicitis, underscoring the importance of vigilant monitoring and prompt intervention.<\/jats:p>\n                    <jats:p>We also explored factors contributing to IUD perforation risk, imaging modalities for detection, and emphasizes the necessity of surgical removal upon confirmation. We highlight the fact that despite the atypical presentation with minimal symptoms, we should always consider emergency situations. Surgical intervention, particularly laparoscopy, may be the standard approach for managing migrated IUDs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>We insist about the critical need for thorough assessment and vigilance in managing IUD-related complications, emphasizing timely intervention to ensure patient safety. This case contributes valuable insights into the complexities surrounding IUD migration, urging healthcare professionals to remain attentive to potential injuries in patients with a history of IUD insertion and abdominal pain.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Highlights<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2024.109515","type":"journal-article","created":{"date-parts":[[2024,3,11]],"date-time":"2024-03-11T05:35:22Z","timestamp":1710135322000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["Intrauterine device migration resulting in acute appendicitis: A case report"],"prefix":"10.1097","volume":"117","author":[{"given":"A.","family":"Sebai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Elaifia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Atri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Hammami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Haddad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.M.","family":"Kacem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-57-20260423","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/0028-2243(84)90068-6","article-title":"Uterine perforation by copper intrauterine device","volume":"17","author":"Heinonen,","year":"1984","journal-title":"Eur. J. Obstet. Gynecol. Reprod. Biol."},{"key":"R2-57-20260423","first-page":"239","article-title":"Gastrointestinal complications of modern intrauterine devices","volume":"55","author":"Key,","year":"1980","journal-title":"Obstet. Gynecol."},{"key":"R3-57-20260423","doi-asserted-by":"crossref","first-page":"127","DOI":"10.2147\/OAJC.S85755","article-title":"New developments in intrauterine device use: focus on the US","volume":"7","author":"Nelson,","year":"2016","journal-title":"OAJC"},{"key":"R4-57-20260423","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S0301-2115(99)00142-6","article-title":"Appendix perforation by an intrauterine contraceptive device","volume":"88","author":"Ohana,","year":"2000","journal-title":"Eur. J. Obstet. Gynecol. Reprod. Biol."},{"key":"R5-57-20260423","doi-asserted-by":"crossref","first-page":"1","DOI":"10.31487\/j.SCR.2021.02.20","article-title":"Removal of migrated intrauterine devices to appendix, small intestine and omentum: case reports","author":"Freijo,","year":"2021","journal-title":"SCR"},{"key":"R6-57-20260423","first-page":"31","article-title":"Risk of uterine perforation among users of intrauterine devices","volume":"61","author":"Heartwell,","year":"1983","journal-title":"Obstet. Gynecol."},{"key":"R7-57-20260423","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1097\/JS9.0000000000000373","article-title":"The SCARE 2023 guideline: updating consensus Surgical CAse REport (SCARE) guidelines","volume":"109","author":"Sohrabi,","year":"2023","journal-title":"Int. J. Surg."},{"key":"R8-57-20260423","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1148\/rg.322115068","article-title":"Migration of intrauterine devices: radiologic findings and implications for patient care","volume":"32","author":"Boortz,","year":"2012","journal-title":"RadioGraphics"},{"key":"R9-57-20260423","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/S0010-7824(98)00029-8","article-title":"Perforations with intrauterine devices","volume":"57","author":"Andersson,","year":"1998","journal-title":"Contraception"},{"key":"R10-57-20260423","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1080\/ejc.8.3.150.155","article-title":"Analysis of risk factors associated with uterine perforation by intrauterine devices","volume":"8","author":"Caliskan,","year":"2003","journal-title":"Eur J Contracept Reprod Health Care"},{"key":"R11-57-20260423","doi-asserted-by":"crossref","DOI":"10.1002\/ccr3.4283","article-title":"Migration of intrauterine device caused asymptomatic acute appendicitis: a case report","volume":"9","author":"Zamani Bonab,","year":"2021","journal-title":"Clin. Case Reports"},{"key":"R12-57-20260423","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1136\/bmj.1.5798.508-a","article-title":"Removal of extrauterine Saf-T-coil through laparoscope","volume":"1","author":"Ledward,","year":"1972","journal-title":"BMJ"},{"key":"R13-57-20260423","first-page":"335","article-title":"Complete and Partial Uterine Perforation and Embedding Following Insertion of Intrauterine Deives. I. Classification, Complications, Mechanism, Incidence, and Missing String: Obstetrical & Gynecological Survey","volume":"36","author":"Zakin,","year":"1981"},{"key":"R14-57-20260423","doi-asserted-by":"crossref","first-page":"5414","DOI":"10.3748\/wjg.v11.i34.5414","article-title":"Intrauterine contraceptive device appendicitis: a case report","volume":"11","author":"Chang,","year":"2005","journal-title":"WJG"},{"key":"R15-57-20260423","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1016\/S0002-9378(15)33284-1","article-title":"Appendiceal perforation by Copper-7 intrauterine contraceptive device","volume":"141","author":"Carson,","year":"1981","journal-title":"Am. J. Obstet. Gynecol."},{"key":"R16-57-20260423","article-title":"Appendiceal perforation caused by an intrauterine contraceptive device: a case report","volume":"36","author":"Maree,","year":"2022","journal-title":"Case Rep. Women's Health"},{"key":"R17-57-20260423","doi-asserted-by":"crossref","first-page":"1546","DOI":"10.1093\/humrep\/det074","article-title":"Uterine perforation caused by intrauterine devices: clinical course and treatment","volume":"28","author":"Kaislasuo,","year":"2013","journal-title":"Hum. Reprod."},{"key":"R18-57-20260423","doi-asserted-by":"crossref","first-page":"358","DOI":"10.12891\/ceog1840.2015","article-title":"Surgical management of intrauterine devices migrated towards intra-abdominal structures: 20-year experience of a tertiary center","volume":"42","author":"Adiyeke,","year":"2015","journal-title":"Clin. Exp. Obstet. Gynecol."},{"key":"R19-57-20260423","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.ijscr.2017.10.038","article-title":"Pelvic abscess complicating sigmoid colon perforation by migrating intrauterine device: a case report and review of the literature","volume":"42","author":"Toumi,","year":"2018","journal-title":"Int. J. Surg. Case Rep."},{"key":"R20-57-20260423","doi-asserted-by":"crossref","first-page":"236","DOI":"10.4293\/108680812X13427982377265","article-title":"Elective surgical removal of migrated intrauterine contraceptive devices from within the peritoneal cavity: a comparison between open and laparoscopic removal","volume":"16","author":"Mosley,","year":"2012","journal-title":"JSLS"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261224002967?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261224002967?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2024.109515","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T21:02:06Z","timestamp":1776978126000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2024.109515"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4]]},"references-count":20,"journal-issue":{"issue":"C","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2024.109515","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2024,4]]},"assertion":[{"value":"2024-02-07","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-03-07","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}