{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,18]],"date-time":"2026-07-18T09:29:10Z","timestamp":1784366950339,"version":"3.55.0"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"C","license":[{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T00:00:00Z","timestamp":1722297600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>Due to its ability to provide stable fixation and permit early mobilization, volar plating has become the recommended technique for the surgical stabilization of distal radius fractures. The extensor pollicis longus (EPL) tendon may be injured or ruptured as a result of undetected screw penetration or drill plunging. During surgery, it is critical to detect any potential screw penetration so that it can be corrected.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case presentation:<\/jats:title>\n                    <jats:p>A 32-year-old woman presented six weeks post-distal radius plating with an inability to extend her left thumb. Clinical examination revealed loss of extension at the interphalangeal joint, stiff wrist, tender point over the dorsal aspect of the wrist, and an intact sensory nerve function.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion:<\/jats:title>\n                    <jats:p>Dynamic ultrasound and magnetic resonance imaging (MRI) both revealed no evidence of tendon rupture or EPL tendon movement. X-rays revealed the distal epiphyseal screws penetrating the far cortex. Intraoperatively, the EPL tendon was found to be impinged by a screw. The tendon was released, tenolysis was performed, and the distal screws were shortened.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>In order to assess screw penetration into the far cortex, volar plating for distal radius fractures should be performed using intraoperative imaging views such as lateral, 45-degree supination, 45-degree pronation, dorsal tangential, and skyline views. Timely interventions after distal radius fracture fixation preserve tendon function, and early detection of tendon compromise is essential to preventing additional damage.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Highlights<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2024.110105","type":"journal-article","created":{"date-parts":[[2024,7,31]],"date-time":"2024-07-31T18:29:34Z","timestamp":1722450574000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Extensor pollicis longus tendon penetration by a screw post-distal radius fracture plating in a young woman: A case report"],"prefix":"10.1097","volume":"122","author":[{"given":"Jaber","family":"AlKhyeli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed Mohamed","family":"Yousif Mohamed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohanad","family":"Abdulgadir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"issue":"2","key":"R1-68-20260325","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1142\/S0218810413500196","article-title":"Extensor pollicis longus tendon ruptures after the use of volar locking plates for distal radius fractures","volume":"18","author":"Zenke,","year":"2013","journal-title":"Hand Surg."},{"issue":"7","key":"R2-68-20260325","doi-asserted-by":"crossref","first-page":"1568","DOI":"10.2106\/JBJS.H.00722","article-title":"Unstable distal radial fractures treated with external fixation, a radial column plate, or a volar plate. A prospective randomized trial","volume":"91","author":"Wei,","year":"2009","journal-title":"J. Bone Joint Surg. Am."},{"issue":"1","key":"R3-68-20260325","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.otsr.2017.08.020","article-title":"Complications following open reduction and internal fixation versus external fixation in treating unstable distal radius fractures: grading the evidence through a meta-analysis","volume":"104","author":"Yuan,","year":"2018","journal-title":"Orthop. Traumatol. Surg. Res."},{"issue":"10","key":"R4-68-20260325","doi-asserted-by":"crossref","first-page":"e408","DOI":"10.1097\/BOT.0000000000000361","article-title":"Dorsal screw penetration with the use of volar plating of distal radius fractures: how can you best detect?","volume":"29","author":"Hill,","year":"2015","journal-title":"J. Orthop. Trauma"},{"issue":"3","key":"R5-68-20260325","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1007\/s11552-007-9038-2","article-title":"Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study","volume":"2","author":"Maschke,","year":"2007","journal-title":"Hand (N Y)"},{"issue":"3","key":"R6-68-20260325","first-page":"269","article-title":"What must be the volar plate screw length to prevent extensor tendon injuries for distal radius fractures fixation?","volume":"10","author":"Toker,","year":"2021","journal-title":"Hand Microsurg."},{"issue":"1","key":"R7-68-20260325","first-page":"50","article-title":"Spontaneous rupture of the extensor pollicis longus tendon after conservative treatment of a non-displaced distal radius fracture in an adolescent","volume":"37","author":"Masquijo,","year":"2023","journal-title":"Acta Ortop. Mex."},{"issue":"2","key":"R8-68-20260325","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1142\/S0218810413500196","article-title":"Extensor pollicis longus tendon ruptures after the use of volar locking plates for distal radius fractures","volume":"18","author":"Zenke,","year":"2013","journal-title":"Hand Surg."},{"issue":"5","key":"R9-68-20260325","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1097\/JS9.0000000000000373","article-title":"The SCARE 2023 guideline: updating consensus Surgical CAse REport (SCARE) guidelines","volume":"109","author":"Sohrabi,","year":"2023","journal-title":"Int. J. Surg."},{"issue":"5","key":"R10-68-20260325","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1097\/BOT.0b013e318059b993","article-title":"Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate","volume":"21","author":"Arora,","year":"2007","journal-title":"J. Orthop. Trauma"},{"key":"R11-68-20260325","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1097\/01.blo.0000223998.02765.0d","article-title":"Two potential causes of EPL rupture after distal radius volar plate fixation","volume":"451","author":"Benson,","year":"2006","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"5","key":"R12-68-20260325","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1097\/BOT.0b013e318059b993","article-title":"Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate","volume":"21","author":"Arora,","year":"2007","journal-title":"J. Orthop. Trauma"},{"issue":"5","key":"R13-68-20260325","doi-asserted-by":"crossref","first-page":"W199","DOI":"10.2214\/AJR.08.1057","article-title":"Screw impingement on the extensor tendons in distal radius fractures treated by volar plating: sonographic appearance","volume":"191","author":"Bianchi,","year":"2008","journal-title":"AJR Am. J. Roentgenol."},{"issue":"1","key":"R14-68-20260325","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1142\/S2424835518500030","article-title":"Use of computed tomography in determining the occurrence of dorsal and intra-articular screw penetration in volar locking plate osteosynthesis of distal radius fracture","volume":"23","author":"Diong,","year":"2018","journal-title":"J Hand Surg Asian Pac Vol"},{"issue":"1","key":"R15-68-20260325","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1186\/s13018-018-0774-5","article-title":"Ultrasonography or direct radiography? A comparison of two techniques to detect dorsal screw penetration after volar plate fixation","volume":"13","author":"Oc,","year":"2018","journal-title":"J. Orthop. Surg. Res."},{"issue":"4","key":"R16-68-20260325","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1055\/s-0037-1603656","article-title":"Detections of screw penetration during volar plating for distal radius fractures","volume":"6","author":"Cha,","year":"2017","journal-title":"J Wrist Surg."},{"key":"R17-68-20260325","doi-asserted-by":"crossref","DOI":"10.1155\/2017\/1402517","article-title":"Comparing dorsal tangential and lateral views of the wrist for detecting dorsal screw penetration after volar plating of distal radius fractures","volume":"2017","author":"Giugale,","year":"2017","journal-title":"Adv Orthop."},{"issue":"4","key":"R18-68-20260325","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1055\/s-0034-1394132","article-title":"The utility of the fluoroscopic skyline view during volar locking plate fixation of distal radius fractures","volume":"3","author":"Vaiss,","year":"2014","journal-title":"J Wrist Surg."},{"key":"R19-68-20260325","doi-asserted-by":"crossref","DOI":"10.1016\/j.ijscr.2022.106869","article-title":"Simple surgical technique for minimizing the risk of extensor pollicis longus rupture following volar plate fixation of distal radial fracture: a case report","volume":"92","author":"Hara,","year":"2022","journal-title":"Int. J. Surg. Case Rep."},{"issue":"2","key":"R20-68-20260325","doi-asserted-by":"crossref","first-page":"e259","DOI":"10.3928\/01477447-20201210-08","article-title":"Effect of downsized screw selection on bone healing and postoperative complications in volar plating of distal radius fractures","volume":"44","author":"Ohno,","year":"2021","journal-title":"Orthopedics"}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261224008861?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261224008861?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2024.110105","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T10:23:17Z","timestamp":1774434197000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2024.110105"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9]]},"references-count":20,"journal-issue":{"issue":"C","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2024.110105","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2024,9]]},"assertion":[{"value":"2024-07-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-07-29","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}