{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,30]],"date-time":"2026-08-30T13:06:35Z","timestamp":1788095195912,"version":"build-2803163510"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"C","license":[{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,1,22]],"date-time":"2025-01-22T00:00:00Z","timestamp":1737504000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,2]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>Suture-mediated vascular closure devices have been widely used in catheter ablation, with 0.14-0.3 % incidence of pseudoaneurysm complications. Here, we report the only case at our institution to date of an infectious pseudoaneurysm caused by a suture-mediated vascular closure device following catheter ablation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Presentation of case:<\/jats:title>\n                    <jats:p>\n                      An 80-year-old man developed a fever 7 days after an atrial fibrillation ablation procedure, using a suture-mediated vascular closure device. Blood cultures revealed the presence of\n                      <jats:italic toggle=\"yes\">Staphylococcus aureus<\/jats:italic>\n                      . Subsequently, a rapidly enlarging mass appeared in the right thigh on the 14th postoperative day.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion:<\/jats:title>\n                    <jats:p>Computed tomography was suggestive of a pseudoaneurysm, and surgical repair was performed. The mass was incised under balloon expansion at the right common femoral artery, and intraoperative findings confirmed the perforation of the femoral artery and adhesion of the infected tissue, necessitating vascular repair and debridement of the infected area. In our institution's experience, the incidence rate of infectious pseudoaneurysms after the use of vascular closure devices is extremely low at 0.04 %.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Although local infections associated with suturing devices are exceedingly rare, prompt intervention is essential when they occur. This report raises awareness of the importance of diagnosing and managing infected pseudoaneurysms, a complication following catheter ablation, as the onset of the condition occurs with a time lag compared to systemic symptoms.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Highlights<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1016\/j.ijscr.2025.110939","type":"journal-article","created":{"date-parts":[[2025,1,23]],"date-time":"2025-01-23T13:53:53Z","timestamp":1737640433000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Infected pseudoaneurysm caused by suture-mediated vascular closure after ablation of atrial fibrillation: A case report"],"prefix":"10.1097","volume":"127","author":[{"given":"Yusuke","family":"Sakamoto","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Osanai","family":"Hiroyuki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eiji","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenji","family":"Arai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-116-20260325","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.4244\/EIJ-D-16-00408","article-title":"Propensity-matched comparison of percutaneous and surgical cut-down approaches in transfemoral transcatheter aortic valve implantation using a balloon-expandable valve","volume":"12","author":"Kawashima,","year":"2017","journal-title":"EuroIntervention"},{"key":"R2-116-20260325","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1016\/j.jvs.2015.08.111","article-title":"Safety and utility of total percutaneous endovascular aortic repair with a single Perclose ProGlide closure device","volume":"63","author":"Ichihashi,","year":"2016","journal-title":"J. Vasc. Surg."},{"key":"R3-116-20260325","doi-asserted-by":"crossref","first-page":"1181","DOI":"10.1016\/j.jvs.2013.10.101","article-title":"A multicenter, randomized, controlled trial of totally percutaneous access versus open femoral exposure for endovascular aortic aneurysm repair (the PEVAR trial)","volume":"59","author":"Nelson,","year":"2014","journal-title":"J. Vasc. Surg."},{"key":"R4-116-20260325","first-page":"311","article-title":"Use of a percutaneous suture-mediated closure system after 6-8F transfemoral approaches: results for 2200 patients","volume":"184","author":"Kamusella,","year":"2012","journal-title":"R\u00f6Fo - Fortschritte auf dem Gebiet der R\u00f6ntgenstrahlen."},{"key":"R5-116-20260325","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.ihj.2016.06.008","article-title":"24h and 30 day outcome of Perclose Proglide suture mediated vascular closure device: an Indian experience","volume":"69","author":"Vinayakumar,","year":"2017","journal-title":"Indian Heart J."},{"key":"R6-116-20260325","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1097\/JS9.0000000000000373","article-title":"The SCARE 2023 guideline: updating consensus surgical CAse REport (SCARE) guidelines","volume":"109","author":"Sohrabi,","year":"2023","journal-title":"Int J Surg Lond Engl."},{"key":"R7-116-20260325","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1111\/pace.14753","article-title":"Efficacy and safety of Proglide use and early discharge after atrial fibrillation ablation compared to standard approach","volume":"46","author":"Castro-Urda,","year":"2023","journal-title":"PROFA trial. Pacing Clin Electrophysiol."},{"key":"R8-116-20260325","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.4065\/80.8.1011","article-title":"Infectious complications of percutaneous vascular closure devices","volume":"80","author":"Sohail,","year":"2005","journal-title":"Mayo Clin. Proc."},{"key":"R9-116-20260325","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1067\/mva.2001.120033","article-title":"Femoral artery infections associated with percutaneous arterial closure devices","volume":"34","author":"Johanning,","year":"2001","journal-title":"J. Vasc. Surg."},{"key":"R10-116-20260325","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1067\/mva.2000.105678","article-title":"Early experience with infectious complications of percutaneous femoral artery closure devices","volume":"32","author":"Pipkin,","year":"2000","journal-title":"J. Vasc. Surg."}],"container-title":["International Journal of Surgery Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261225001257?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2210261225001257?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2025.110939","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T10:24:11Z","timestamp":1774434251000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1016\/j.ijscr.2025.110939"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2]]},"references-count":10,"journal-issue":{"issue":"C","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1016\/j.ijscr.2025.110939","relation":{},"ISSN":["2210-2612"],"issn-type":[{"value":"2210-2612","type":"print"}],"subject":[],"published":{"date-parts":[[2025,2]]},"assertion":[{"value":"2024-12-07","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}