{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T11:36:48Z","timestamp":1769168208388,"version":"3.49.0"},"reference-count":27,"publisher":"International Journal of Spine Surgery","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The International Journal of Spine Surgery"],"published-print":{"date-parts":[[2012,12]]},"DOI":"10.1016\/j.ijsp.2012.03.002","type":"journal-article","created":{"date-parts":[[2012,9,24]],"date-time":"2012-09-24T00:45:17Z","timestamp":1348447517000},"page":"145-156","source":"Crossref","is-referenced-by-count":11,"title":["Comparison of in vivo and simulator-retrieved metal-on-metal cervical disc replacements"],"prefix":"10.14444","volume":"6","author":[{"given":"Steven M.","family":"Kurtz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lauren","family":"Ciccarelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Megan L.","family":"Harper","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryan","family":"Siskey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacob","family":"Shorez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank W.","family":"Chan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"5581","reference":[{"issue":"Suppl","key":"10.1016\/j.ijsp.2012.03.002_bib1","doi-asserted-by":"crossref","first-page":"292S","DOI":"10.1016\/j.spinee.2004.07.023","article-title":"Goals of cervical disc replacement","volume":"4","author":"Albert","year":"2004","journal-title":"Spine J"},{"issue":"Suppl","key":"10.1016\/j.ijsp.2012.03.002_bib2","doi-asserted-by":"crossref","first-page":"S27","DOI":"10.1097\/01.brs.0000175192.55139.69","article-title":"Cervical disc replacement","volume":"30","author":"Phillips","year":"2005","journal-title":"Spine"},{"key":"10.1016\/j.ijsp.2012.03.002_bib3","first-page":"154","article-title":"Arthroplasty with intercorporal endoprothesis in herniated disc and in painful disc","volume":"357","author":"Fernstr\u00f6m","year":"1966","journal-title":"Acta Chir Scand Suppl"},{"key":"10.1016\/j.ijsp.2012.03.002_bib4","first-page":"881","article-title":"Intractable headache and cervico-brachialgia treated by complete replacement of cervical intervertebral discs with a metal prosthesis","volume":"38","author":"Reitz","year":"1964","journal-title":"S Afr Med J"},{"key":"10.1016\/j.ijsp.2012.03.002_bib5","doi-asserted-by":"crossref","first-page":"943","DOI":"10.3171\/jns.1998.88.6.0943","article-title":"Surgical experience with an implanted artificial cervical joint","volume":"88","author":"Cummins","year":"1998","journal-title":"J Neurosurg"},{"key":"10.1016\/j.ijsp.2012.03.002_bib6","series-title":"Spine Technology Handbook","first-page":"303","article-title":"Total disc arthroplasty","author":"Kurtz","year":"2006"},{"key":"10.1016\/j.ijsp.2012.03.002_bib7","series-title":"Presented at the Seventh Annual Meeting of the Spine Arthroplasty Society","article-title":"Two-year results from a prospective, randomized IDE study of the Prestige ST cervical disc [abstract PA-WE01]","author":"Burkus","year":"2007"},{"key":"10.1016\/j.ijsp.2012.03.002_bib8","first-page":"202","article-title":"A comparison of simulator-tested and -retrieved cervical disc prostheses","volume":"1","author":"Anderson","year":"2004","journal-title":"J Neurosurg"},{"key":"10.1016\/j.ijsp.2012.03.002_bib9","series-title":"Standard Guide for Functional, Kinematic, and Wear Assessment of Total Disc Prostheses","year":"2005"},{"key":"10.1016\/j.ijsp.2012.03.002_bib10","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1002\/jbm.b.30537","article-title":"Digital photogrammetry for quantitative wear analysis of retrieved TKA components","volume":"79","author":"Grochowsky","year":"2006","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"10.1016\/j.ijsp.2012.03.002_bib11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1520\/JAI100252","article-title":"Retrieval analysis of total disc replacements: Implications for standardized wear testing","volume":"3","author":"Kurtz","year":"2006","journal-title":"J ASTM Int"},{"key":"10.1016\/j.ijsp.2012.03.002_bib12","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1002\/jbm.820170510","article-title":"Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prostheses","volume":"17","author":"Hood","year":"1983","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.ijsp.2012.03.002_bib13","series-title":"Presented at the 12th International Meeting on Advanced Spine Techniques","article-title":"In vivo wear mechanisms of a retrieved metal-on-metal total disc replacement","author":"Kurtz","year":"2005"},{"key":"10.1016\/j.ijsp.2012.03.002_bib14","doi-asserted-by":"crossref","first-page":"E6","DOI":"10.3171\/foc.2004.17.3.6","article-title":"Clinical outcomes with the Prestige II cervical disc: Preliminary results from a prospective randomized clinical trial","volume":"17","author":"Porchet","year":"2004","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.ijsp.2012.03.002_bib15","series-title":"Alternative Bearing Surfaces in Total Joint Replacement","first-page":"1","article-title":"Predicting the clinical wear performance of orthopaedic bearing surfaces","author":"Sauer","year":"1998"},{"issue":"Suppl 3","key":"10.1016\/j.ijsp.2012.03.002_bib16","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.arth.2004.09.019","article-title":"Can metal levels be used to monitor metal-on-metal hip arthroplasties?","volume":"19","author":"Jacobs","year":"2004","journal-title":"J Arthroplasty"},{"issue":"Suppl 3","key":"10.1016\/j.ijsp.2012.03.002_bib17","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.arth.2004.09.009","article-title":"A consensus paper on metal ions in metal-on-metal hip arthroplasties","volume":"19","author":"MacDonald","year":"2004","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.ijsp.2012.03.002_bib18","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/00003086-199912000-00003","article-title":"The Otto Aufranc Award","author":"Chan","year":"1999","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.ijsp.2012.03.002_bib19","series-title":"Presented at the Seventh Annual Meeting of the Spine Arthroplasty Society","article-title":"Serum metal ion levels in patients with metal-on-metal cervical disc replacements [abstract PA-WE13]","author":"Burkus","year":"2007"},{"key":"10.1016\/j.ijsp.2012.03.002_bib20","first-page":"247","article-title":"Corrosion on spinal implants","volume":"18","author":"Kirkpatrick","year":"2005","journal-title":"J Spinal Disord Tech"},{"key":"10.1016\/j.ijsp.2012.03.002_bib21","doi-asserted-by":"crossref","first-page":"2454","DOI":"10.1097\/01.brs.0000239132.16484.be","article-title":"Wear and corrosion in retrieved thoracolumbar posterior internal fixation","volume":"31","author":"Villarraga","year":"2006","journal-title":"Spine"},{"issue":"Suppl 3","key":"10.1016\/j.ijsp.2012.03.002_bib22","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.arth.2005.05.001","article-title":"Cracking and impingement in ultra-high-molecular-weight polyethylene acetabular liners","volume":"20","author":"Birman","year":"2005","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.ijsp.2012.03.002_bib23","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/j.arth.2005.01.025","article-title":"Impingement contributes to backside wear and screw-metallic shell fretting in modular acetabular cups","volume":"22","author":"Kligman","year":"2007","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.ijsp.2012.03.002_bib24","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/j.arth.2004.09.058","article-title":"Impingement in total hip arthroplasty a study of retrieved acetabular components","volume":"20","author":"Shon","year":"2005","journal-title":"J Arthroplasty"},{"issue":"Suppl 2","key":"10.1016\/j.ijsp.2012.03.002_bib25","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.arth.2006.05.013","article-title":"Does neck\/liner impingement increase wear of ultrahigh-molecular-weight polyethylene liners?","volume":"21","author":"Usrey","year":"2006","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.ijsp.2012.03.002_bib26","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.spinee.2006.05.012","article-title":"Polyethylene wear and rim fracture in total disc arthroplasty","volume":"7","author":"Kurtz","year":"2007","journal-title":"Spine J"},{"key":"10.1016\/j.ijsp.2012.03.002_bib27","series-title":"Presented at the Seventh Annual Meeting of the Spine Arthroplasty Society","article-title":"Retrieval analysis of ProDisc total disc replacements [abstract P124]","author":"Wright","year":"2007"}],"container-title":["The International Journal of Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/ijssurgery.com\/lookup\/doi\/10.1016\/j.ijsp.2012.03.002","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,16]],"date-time":"2025-01-16T20:49:08Z","timestamp":1737060548000},"score":1,"resource":{"primary":{"URL":"http:\/\/ijssurgery.com\/10.1016\/j.ijsp.2012.03.002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,12]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2012,12]]}},"alternative-id":["S2211459912000215"],"URL":"https:\/\/doi.org\/10.1016\/j.ijsp.2012.03.002","relation":{},"ISSN":["2211-4599"],"issn-type":[{"value":"2211-4599","type":"print"}],"subject":[],"published":{"date-parts":[[2012,12]]}}}