{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T19:11:26Z","timestamp":1776971486291,"version":"3.51.4"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","license":[{"start":{"date-parts":[[2017,12,1]],"date-time":"2017-12-01T00:00:00Z","timestamp":1512086400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,12,1]],"date-time":"2019-12-01T00:00:00Z","timestamp":1575158400000},"content-version":"vor","delay-in-days":730,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Surgery"],"published-print":{"date-parts":[[2017,12]]},"DOI":"10.1016\/j.ijsu.2017.10.071","type":"journal-article","created":{"date-parts":[[2017,11,1]],"date-time":"2017-11-01T05:19:41Z","timestamp":1509513581000},"page":"155-159","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":15,"special_numbering":"C","title":["Feasibility and safety of nerve stimulator attachment to energy-based devices: A porcine model study"],"prefix":"10.1097","volume":"48","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2329-0648","authenticated-orcid":false,"given":"Sung-Chan","family":"Shin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eui-Suk","family":"Sung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sung-Won","family":"Choi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sung-Dong","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Da-Woon","family":"Jung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seok-Hyun","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jung Hoon","family":"Ro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jin-Choon","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Byung-Joo","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"10.1016\/j.ijsu.2017.10.071_bib1","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.amjsurg.2010.07.047","article-title":"Randomized clinical trial on Harmonic Focus shears versus clamp-and-tie technique for total thyroidectomy","volume":"202","author":"Mourad","year":"2011","journal-title":"Am. J. Surg."},{"issue":"Suppl 1","key":"10.1016\/j.ijsu.2017.10.071_bib2","doi-asserted-by":"crossref","first-page":"S189","DOI":"10.1016\/j.ijsu.2014.05.011","article-title":"Sutureless thyroidectomy","volume":"12","author":"Ruggiero","year":"2014","journal-title":"Int. J. Surg."},{"key":"10.1016\/j.ijsu.2017.10.071_bib3","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1016\/j.otohns.2009.06.745","article-title":"Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy","volume":"141","author":"Pons","year":"2009","journal-title":"Otolaryngol. Head. Neck Surg."},{"issue":"Suppl 1","key":"10.1016\/j.ijsu.2017.10.071_bib4","doi-asserted-by":"crossref","first-page":"S22","DOI":"10.1016\/j.ijsu.2015.12.050","article-title":"Complications in thyroid surgery. Harmonic scalpel, harmonic Focus versus conventional hemostasis: a meta-analysis","volume":"28","author":"Revelli","year":"2016","journal-title":"Int. J. Surg."},{"key":"10.1016\/j.ijsu.2017.10.071_bib5","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1016\/j.urology.2007.11.035","article-title":"Tissue response to surgical energy devices","volume":"71","author":"Phillips","year":"2008","journal-title":"Urology"},{"issue":"Suppl 1","key":"10.1016\/j.ijsu.2017.10.071_bib6","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1002\/lary.21119","article-title":"Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement","volume":"121","author":"Randolph","year":"2011","journal-title":"Laryngoscope"},{"key":"10.1016\/j.ijsu.2017.10.071_bib7","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1007\/s00268-013-2260-x","article-title":"Intraoperative nerve monitoring can reduce prevalence of recurrent laryngeal nerve injury in thyroid reoperations: results of a retrospective cohort study","volume":"38","author":"Barczynski","year":"2014","journal-title":"World J. Surg."},{"key":"10.1016\/j.ijsu.2017.10.071_bib8","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.jss.2013.12.022","article-title":"Systematic review with meta-analysis of studies comparing intraoperative neuromonitoring of recurrent laryngeal nerves versus visualization alone during thyroidectomy","volume":"188","author":"Pisanu","year":"2014","journal-title":"J. Surg. Res."},{"key":"10.1016\/j.ijsu.2017.10.071_bib9","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.ijsu.2017.01.086","article-title":"Systematic review with meta-analysis of intraoperative neuromonitoring during thyroidectomy","volume":"39","author":"Yang","year":"2017","journal-title":"Int. J. Surg."},{"key":"10.1016\/j.ijsu.2017.10.071_bib10","doi-asserted-by":"crossref","first-page":"1340","DOI":"10.1007\/s00268-012-1547-7","article-title":"Randomized controlled trial of visualization versus neuromonitoring of the external branch of the superior laryngeal nerve during thyroidectomy","volume":"36","author":"Barczynski","year":"2012","journal-title":"World J. Surg."},{"key":"10.1016\/j.ijsu.2017.10.071_bib11","doi-asserted-by":"crossref","first-page":"2838","DOI":"10.1002\/lary.25412","article-title":"Recurrent laryngeal nerve safety parameters of the Harmonic Focus during thyroid surgery: porcine model using continuous monitoring","volume":"125","author":"Wu","year":"2015","journal-title":"Laryngoscope"},{"key":"10.1016\/j.ijsu.2017.10.071_bib12","article-title":"Safety of LigaSure in recurrent laryngeal nerve dissection-porcine model using continuous monitoring","author":"Dionigi","year":"2016","journal-title":"Laryngoscope"},{"key":"10.1016\/j.ijsu.2017.10.071_bib13","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.jss.2015.06.066","article-title":"Thermal injury of the recurrent laryngeal nerve by THUNDERBEAT during thyroid surgery: findings from continuous intraoperative neuromonitoring in a porcine model","volume":"200","author":"Kwak","year":"2016","journal-title":"J. Surg. Res."}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1743919117314085?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1743919117314085?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2023,2,22]],"date-time":"2023-02-22T16:03:13Z","timestamp":1677081793000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1743919117314085"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12]]},"references-count":13,"alternative-id":["S1743919117314085"],"URL":"https:\/\/doi.org\/10.1016\/j.ijsu.2017.10.071","relation":{},"ISSN":["1743-9191"],"issn-type":[{"value":"1743-9191","type":"print"}],"subject":[],"published":{"date-parts":[[2017,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Feasibility and safety of nerve stimulator attachment to energy-based devices: A porcine model study","name":"articletitle","label":"Article Title"},{"value":"International Journal of Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ijsu.2017.10.071","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}]}}