{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T12:51:56Z","timestamp":1792068716039,"version":"4.4.0"},"reference-count":34,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,8,16]],"date-time":"2026-08-16T00:00:00Z","timestamp":1786838400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Infection Prevention in Practice"],"published-print":{"date-parts":[[2026,12]]},"DOI":"10.1016\/j.infpip.2026.100582","type":"journal-article","created":{"date-parts":[[2026,8,22]],"date-time":"2026-08-22T09:32:53Z","timestamp":1787391173000},"page":"100582","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Usability and microbial validation study of an autonomous UV-C disinfection robot"],"prefix":"10.1016","volume":"8","author":[{"given":"Thomas Roberto","family":"de Jager","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tijn Olivier","family":"Delzenne","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0789-2633","authenticated-orcid":false,"given":"Dennis","family":"Claessen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.infpip.2026.100582_bib1","doi-asserted-by":"crossref","first-page":"2321","DOI":"10.2147\/IDR.S177247","article-title":"Health care-associated infections \u2013 an overview","volume":"11","author":"Haque","year":"2018","journal-title":"Infect Drug Resist"},{"key":"10.1016\/j.infpip.2026.100582_bib2","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pmed.1002150","article-title":"Burden of six healthcare-associated infections on European population health: estimating incidence-based disability-adjusted life years through a population prevalence-based modelling study","volume":"13","author":"Cassini","year":"2016","journal-title":"PLoS Med"},{"key":"10.1016\/j.infpip.2026.100582_bib3","article-title":"Prevalence of bacteria and antimicrobial resistance genes in hospital water and surfaces","volume":"13","author":"Aleem","year":"2021","journal-title":"Cureus"},{"key":"10.1016\/j.infpip.2026.100582_bib4","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1038\/nrmicro3439","article-title":"Tackling antibiotic resistance: the environmental framework","volume":"13","author":"Berendonk","year":"2015","journal-title":"Nat Rev Microbiol"},{"key":"10.1016\/j.infpip.2026.100582_bib5","doi-asserted-by":"crossref","DOI":"10.1136\/bmjoq-2024-002958","article-title":"Right approach: improve-ment in cleaning and disinfection of medical equipment in use \u2013 sheikh shakhbout medical city (ssmc) experience","volume":"14","author":"Al Hajjeh","year":"2025","journal-title":"BMJ Open Quality"},{"key":"10.1016\/j.infpip.2026.100582_bib6","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1016\/j.ajic.2015.03.024","article-title":"Pathogen transfer and high variability in pathogen removal by detergent wipes","volume":"43","author":"Ramm","year":"2015","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.infpip.2026.100582_bib7","first-page":"33","article-title":"Quality and testing of ready-to-use disinfectant wipes","volume":"44","author":"Knieler","year":"2019","journal-title":"Hyg Med"},{"key":"10.1016\/j.infpip.2026.100582_bib8","series-title":"Hygiene of refillable spray bottles ii: research into the hygienic effect of a WIP\/RIVM treatment in simulated use and in institutional cleaning practice. Technical Report","author":"Terpstra","year":"2021"},{"key":"10.1016\/j.infpip.2026.100582_bib9","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1086\/667730","article-title":"Daily disinfection of high-touch surfaces in isolation rooms to reduce contamination of healthcare workers\u2019 hands","volume":"33","author":"Kundrapu","year":"2012","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.infpip.2026.100582_bib10","doi-asserted-by":"crossref","first-page":"2053","DOI":"10.1007\/s10096-017-3042-4","article-title":"High-touch surfaces: microbial neighbours at hand","volume":"36","author":"Cobrado","year":"2017","journal-title":"Eur J Clin Microbiol Infect Dis"},{"key":"10.1016\/j.infpip.2026.100582_bib11","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.jhin.2023.07.017","article-title":"Superiority of manual disinfection using pre-soaked wipes over automatic UV-C radiation without prior cleaning","volume":"140","author":"Knobling","year":"2023","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.infpip.2026.100582_bib12","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/j.aorn.2010.08.022","article-title":"A novel technique for identifying opportunities to improve environmental hygiene in the operating room","volume":"93","author":"Jefferson","year":"2011","journal-title":"AORN J"},{"key":"10.1016\/j.infpip.2026.100582_bib13","doi-asserted-by":"crossref","first-page":"5849","DOI":"10.1038\/s41598-023-32876-y","article-title":"Contact time and disinfectant formulation significantly impact the efficacies of disinfectant towelettes against Candida auris on hard, non-porous surfaces","volume":"13","author":"Voorn","year":"2023","journal-title":"Sci Rep"},{"key":"10.1016\/j.infpip.2026.100582_bib14","doi-asserted-by":"crossref","first-page":"27","DOI":"10.5430\/jha.v8n6p27","article-title":"Cleaning and disinfecting protocols for hospital environmental surfaces: a systematic review of the literature","volume":"8","author":"Taylor","year":"2019","journal-title":"J Hosp Admin"},{"key":"10.1016\/j.infpip.2026.100582_bib15","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1017\/ice.2016.111","article-title":"UV-C light disinfection of carbapenem-resistant Enterobacteriaceae from high-touch surfaces in a patient room and bathroom","volume":"37","author":"Rock","year":"2016","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.infpip.2026.100582_bib16","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1007\/s11908-015-0498-1","article-title":"Touchless technologies for decontamination in the hospital: a review of hydrogen peroxide and UV devices","volume":"17","author":"Doll","year":"2015","journal-title":"Curr Infect Dis Rep"},{"key":"10.1016\/j.infpip.2026.100582_bib17","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1186\/s13756-021-00945-4","article-title":"The use of a UV-C disinfection robot in the routine cleaning process: a field study in an academic hospital","volume":"10","author":"Astrid","year":"2021","journal-title":"Antimicrob Resist Infect Control"},{"key":"10.1016\/j.infpip.2026.100582_bib18","doi-asserted-by":"crossref","DOI":"10.1128\/jb.00102-23","article-title":"Bacillus subtilis, a swiss army knife in science and biotechnology","volume":"205","author":"St\u00fclke","year":"2023","journal-title":"J Bacteriol"},{"key":"10.1016\/j.infpip.2026.100582_bib19","doi-asserted-by":"crossref","DOI":"10.6028\/jres.126.021","article-title":"Sensitivity of bacteria, protozoa, viruses, and other microorganisms to ultraviolet radiation","volume":"126","author":"Masjoudi","year":"2021","journal-title":"J Res Natl Inst Stand Technol"},{"key":"10.1016\/j.infpip.2026.100582_bib20","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1016\/j.radphyschem.2011.11.007","article-title":"Resistance of the genome of Escherichia coli and Listeria monocytogenes to irradiation evaluated by the induction of cyclobutane pyrimidine dimers and 6-4 photoproducts using gamma and UV-C radiations","volume":"81","author":"Beauchamp","year":"2012","journal-title":"Radiat Phys Chem"},{"key":"10.1016\/j.infpip.2026.100582_bib21","doi-asserted-by":"crossref","first-page":"7285","DOI":"10.3390\/app11167285","article-title":"UV light application as a mean for disinfection applied in the dairy industry","volume":"11","author":"Chawla","year":"2021","journal-title":"Appl Sci (Basel)"},{"key":"10.1016\/j.infpip.2026.100582_bib22","article-title":"Description and results of a new method for assessing real-life performance of a UV-C disinfection robot","volume":"5","author":"Rodgers","year":"2023","journal-title":"Infect Prev Pract"},{"key":"10.1016\/j.infpip.2026.100582_bib23","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1017\/ice.2017.268","article-title":"Implementation lessons learned from the benefits of enhanced terminal room (BETR) disinfection study: process and perceptions of enhanced disinfection with ultraviolet disinfection devices","volume":"39","author":"Anderson","year":"2018","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.infpip.2026.100582_bib24","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1186\/s13756-021-00945-4","article-title":"The use of a UV-C disinfection robot in the routine cleaning process: a field study in an academic hospital","volume":"10","author":"F\u00fcszl","year":"2021","journal-title":"Antimicrob Resist Infect Control"},{"key":"10.1016\/j.infpip.2026.100582_bib25","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1086\/655016","article-title":"A quantitative approach to defining \u201chigh-touch\u201d surfaces in hospitals","volume":"31","author":"Huslage","year":"2010","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.infpip.2026.100582_bib26","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1016\/j.ajic.2016.03.013","article-title":"Determining high touch areas in the operating room with levels of contamination","volume":"44","author":"Link","year":"2016","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.infpip.2026.100582_bib27","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1016\/j.jhin.2014.12.024","article-title":"Hand-touch contact assessment of high-touch and mutual-touch surfaces among healthcare workers, patients, and visitors","volume":"90","author":"Cheng","year":"2015","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.infpip.2026.100582_bib28","doi-asserted-by":"crossref","DOI":"10.1016\/j.scitotenv.2023.161848","article-title":"Reflection of UVC wavelengths from common materials during surface UV disinfection: assessment of human UV exposure and ozone generation","volume":"869","author":"Ma","year":"2023","journal-title":"Sci Total Environ"},{"key":"10.1016\/j.infpip.2026.100582_bib29","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1016\/j.ajic.2018.09.030","article-title":"Spores on wheels: wheelchairs are a potential vector for dissemination of pathogens in healthcare facilities","volume":"47","author":"Jencson","year":"2019","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.infpip.2026.100582_bib30","doi-asserted-by":"crossref","first-page":"779","DOI":"10.3390\/ijerph18020779","article-title":"Efficacy of three commercial disinfectants in reducing microbial surfaces\u2019 contaminations of pharmaceuticals hospital facilities","volume":"18","author":"Di Martino","year":"2021","journal-title":"Int J Environ Res Publ Health"},{"key":"10.1016\/j.infpip.2026.100582_bib31","doi-asserted-by":"crossref","first-page":"1312","DOI":"10.1128\/AEM.65.3.1312-1315.1999","article-title":"Pulsed-light inactivation of food-related microorganisms","volume":"65","author":"Rowan","year":"1999","journal-title":"Appl Environ Microbiol"},{"key":"10.1016\/j.infpip.2026.100582_bib32","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.jhin.2022.12.009","article-title":"Shedding a light on ultraviolet-c technologies in the hospital environment","volume":"132","author":"Demeersseman","year":"2023","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.infpip.2026.100582_bib33","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.jhin.2003.09.017","article-title":"How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitals","volume":"56","author":"Dancer","year":"2004","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.infpip.2026.100582_bib34","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1007\/s10096-011-1250-x","article-title":"Hospital cleaning in the 21st century","volume":"30","author":"Dancer","year":"2011","journal-title":"Eur J Clin Microbiol Infect Dis"}],"container-title":["Infection Prevention in Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2590088926000764?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2590088926000764?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T12:17:32Z","timestamp":1792066652000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2590088926000764"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,12]]},"references-count":34,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,12]]}},"alternative-id":["S2590088926000764"],"URL":"https:\/\/doi.org\/10.1016\/j.infpip.2026.100582","relation":{},"ISSN":["2590-0889"],"issn-type":[{"value":"2590-0889","type":"print"}],"subject":[],"published":{"date-parts":[[2026,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Usability and microbial validation study of an autonomous UV-C disinfection robot","name":"articletitle","label":"Article Title"},{"value":"Infection Prevention in Practice","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.infpip.2026.100582","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Ltd on behalf of The Healthcare Infection Society.","name":"copyright","label":"Copyright"}],"article-number":"100582"}}