{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T14:52:22Z","timestamp":1791989542962,"version":"4.4.0"},"reference-count":31,"publisher":"Elsevier BV","issue":"10","content-domain":{"domain":["injuryjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Injury"],"published-print":{"date-parts":[[2013,10]]},"DOI":"10.1016\/j.injury.2013.05.008","type":"journal-article","created":{"date-parts":[[2013,6,12]],"date-time":"2013-06-12T03:46:24Z","timestamp":1371008784000},"page":"1327-1332","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":98,"title":["Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures"],"prefix":"10.1016","volume":"44","author":[{"given":"G\u00f6tz","family":"R\u00f6derer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Scola","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Werner","family":"Schm\u00f6lz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florian","family":"Gebhard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Markus","family":"Windolf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ladina","family":"Hofmann-Fliri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.injury.2013.05.008_bib0005","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.injury.2006.04.130","article-title":"Epidemiology of adult fractures: a review","volume":"37","author":"Court-Brown","year":"2006","journal-title":"Injury"},{"key":"10.1016\/j.injury.2013.05.008_bib0010","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1097\/01.TA.0000170400.68994.AB","article-title":"Locked plate fixation and intramedullary nailing for proximal humerus fractures: a biomechanical evaluation","volume":"58","author":"Hessmann","year":"2005","journal-title":"J Trauma"},{"key":"10.1016\/j.injury.2013.05.008_bib0015","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1097\/01.blo.0000194674.56764.c0","article-title":"New trends in the treatment of proximal humerus fractures","volume":"442","author":"Helmy","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.injury.2013.05.008_bib0020","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1097\/BOT.0b013e318133479c","article-title":"Treatment of proximal humerus fractures","volume":"21","author":"Vallier","year":"2007","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2013.05.008_bib0025","doi-asserted-by":"crossref","first-page":"1919","DOI":"10.2106\/00004623-200211000-00002","article-title":"Open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus","volume":"84-A","author":"Wijgman","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2013.05.008_bib0030","doi-asserted-by":"crossref","first-page":"951","DOI":"10.2106\/00004623-200206000-00009","article-title":"Biomechanical evaluation of proximal humeral fracture fixation supplemented with calcium phosphate cement","volume":"84-A","author":"Kwon","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2013.05.008_bib0035","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1097\/BOT.0b013e3181ccafb3","article-title":"Clinical results for minimally invasive locked plating of proximal humerus fractures","volume":"24","author":"R\u00f6derer","year":"2010","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2013.05.008_bib0040","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1007\/s00264-010-1015-7","article-title":"Second generation locked plating of proximal humerus fractures--a prospective multicentre observational study","volume":"35","author":"R\u00f6derer","year":"2011","journal-title":"Int Orthop"},{"key":"10.1016\/j.injury.2013.05.008_bib0045","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.2106\/JBJS.H.00006","article-title":"Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study","volume":"91","author":"S\u00fcdkamp","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2013.05.008_bib0050","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1097\/BOT.0b013e3181920e5b","article-title":"Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis","volume":"23","author":"Brunner","year":"2009","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2013.05.008_bib0055","doi-asserted-by":"crossref","DOI":"10.1097\/TA.0b013e31821852ed","article-title":"Potential of polymethylmethacrylate cement-augmented helical proximal femoral nail antirotation blades to improve implant stability-A biomechanical investigation in human cadaveric femoral heads","author":"Sermon","year":"2011","journal-title":"J Trauma"},{"key":"10.1016\/j.injury.2013.05.008_bib0060","doi-asserted-by":"crossref","first-page":"1322","DOI":"10.1016\/j.injury.2011.04.010","article-title":"Biomechanical effect of bone cement augmentation on rotational stability and pull-out strength of the proximal femur nail antirotation","volume":"42","author":"Erhart","year":"2011","journal-title":"Injury"},{"key":"10.1016\/j.injury.2013.05.008_bib0065","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/j.jse.2011.09.017","article-title":"Fracture site augmentation with calcium phosphate cement reduces screw penetration after open reduction-internal fixation of proximal humeral fractures","volume":"21","author":"Egol","year":"2012","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.injury.2013.05.008_bib0070","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/j.jse.2005.09.007","article-title":"Proximal humeral fractures: regional differences in bone mineral density of the humeral head affect the fixation strength of cancellous screws","volume":"15","author":"Tingart","year":"2006","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.injury.2013.05.008_bib0075","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1007\/s00223-002-0013-9","article-title":"Three-dimensional distribution of bone density in the proximal humerus","volume":"73","author":"Tingart","year":"2003","journal-title":"Calcif Tissue Int"},{"key":"10.1016\/j.injury.2013.05.008_bib0080","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1016\/j.injury.2011.10.028","article-title":"Where do locking screws purchase in the humeral head?","volume":"43","author":"Brianza","year":"2011","journal-title":"Injury"},{"key":"10.1016\/j.injury.2013.05.008_bib0085","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1007\/s00256-011-1174-7","article-title":"Preoperative assessment of the cancellous bone mineral density of the proximal humerus using CT data","volume":"41","author":"Krappinger","year":"2011","journal-title":"Skeletal Radiol"},{"key":"10.1016\/j.injury.2013.05.008_bib0090","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.1016\/j.injury.2012.07.003","article-title":"The effect of in situ augmentation on implant anchorage in proximal humeral head fractures","volume":"43","author":"Unger","year":"2012","journal-title":"Injury"},{"key":"10.1016\/j.injury.2013.05.008_bib0095","doi-asserted-by":"crossref","first-page":"886","DOI":"10.1016\/j.clinbiomech.2010.06.015","article-title":"Biomechanical evaluation of a new fixation technique for internal fixation of three-part proximal humerus fractures in a novel cadaveric model","volume":"25","author":"Brianza","year":"2010","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"10.1016\/j.injury.2013.05.008_bib0100","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.clinbiomech.2008.09.005","article-title":"Quantification of cancellous bone-compaction due to DHS Blade insertion and influence upon cut-out resistance","volume":"24","author":"Windolf","year":"2009","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"10.1016\/j.injury.2013.05.008_bib0105","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1097\/BOT.0b013e318206eb46","article-title":"Are polyaxially locked screws advantageous in the plate osteosynthesis of proximal humeral fractures in the elderly? A prospective randomized clinical observational study","volume":"25","author":"Voigt","year":"2011","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2013.05.008_bib0110","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.2106\/JBJS.H.00006","article-title":"Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study","volume":"91","author":"Sudkamp","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2013.05.008_bib0115","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1097\/BOT.0b013e31815bb09d","article-title":"Analysis of efficacy and failure in proximal humerus fractures treated with locking plates","volume":"21","author":"Agudelo","year":"2007","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2013.05.008_bib0120","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/BOT.0b013e3181694f7d","article-title":"Percutaneous humeral plating of fractures of the proximal humerus: results of a prospective multicenter clinical trial","volume":"22","author":"Laflamme","year":"2008","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2013.05.008_bib0125","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.2106\/JBJS.H.00133","article-title":"Surgical treatment of three and four-part proximal humeral fractures","volume":"91","author":"Solberg","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2013.05.008_bib0130","first-page":"9","article-title":"Where should implants be anchored in the humeral head?","volume":"1","author":"Hepp","year":"2003","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.injury.2013.05.008_bib0135","doi-asserted-by":"crossref","first-page":"E932","DOI":"10.1097\/BRS.0b013e3181c6ec60","article-title":"Revision of cannulated and perforated cement-augmented pedicle screws: a biomechanical study in human cadavers","volume":"35","author":"Bullmann","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.injury.2013.05.008_bib0140","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1016\/j.clinbiomech.2009.05.002","article-title":"Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: influences of radial hole and pilot hole tapping","volume":"24","author":"Chen","year":"2009","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"10.1016\/j.injury.2013.05.008_bib0145","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1002\/jbm.b.31353","article-title":"Temperature evaluation during PMMA screw augmentation in osteoporotic bone \u2013 an in vitro study about the risk of thermal necrosis in human femoral heads","volume":"90","author":"Boner","year":"2009","journal-title":"J Biomed Mater Res B: Appl Biomater"},{"key":"10.1016\/j.injury.2013.05.008_bib0150","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.clinbiomech.2004.01.014","article-title":"Femoroplasty-augmentation of mechanical properties in the osteoporotic proximal femur: a biomechanical investigation of PMMA reinforcement in cadaver bones","volume":"19","author":"Heini","year":"2004","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"10.1016\/j.injury.2013.05.008_bib0155","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1097\/TA.0b013e318248bfa7","article-title":"Ex vivo evaluation of the polymerization temperatures during cement augmentation of proximal femoral nail antirotation blades","volume":"72","author":"Fliri","year":"2012","journal-title":"J Trauma Acute Care Surg"}],"container-title":["Injury"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138313002362?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138313002362?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,7,15]],"date-time":"2019-07-15T03:07:27Z","timestamp":1563160047000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0020138313002362"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,10]]},"references-count":31,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2013,10]]}},"alternative-id":["S0020138313002362"],"URL":"https:\/\/doi.org\/10.1016\/j.injury.2013.05.008","relation":{},"ISSN":["0020-1383"],"issn-type":[{"value":"0020-1383","type":"print"}],"subject":[],"published":{"date-parts":[[2013,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures","name":"articletitle","label":"Article Title"},{"value":"Injury","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.injury.2013.05.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}