{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T10:19:32Z","timestamp":1773829172700,"version":"3.50.1"},"reference-count":35,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2015,6,1]],"date-time":"2015-06-01T00:00:00Z","timestamp":1433116800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","injuryjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Injury"],"published-print":{"date-parts":[[2015,6]]},"DOI":"10.1016\/j.injury.2015.01.020","type":"journal-article","created":{"date-parts":[[2015,1,31]],"date-time":"2015-01-31T15:48:07Z","timestamp":1422719287000},"page":"1150-1155","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":58,"title":["Application of 3D printed customized external fixator in fracture reduction"],"prefix":"10.1016","volume":"46","author":[{"given":"Feng","family":"Qiao","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dichen","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhongmin","family":"Jin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yongchang","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tao","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinlong","family":"He","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Li","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.injury.2015.01.020_bib0180","first-page":"188","article-title":"Epidemiology of diaphyseal and distal femoral fractures in Rochester","author":"Arneson","year":"1988","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.injury.2015.01.020_bib0185","article-title":"Osteogenic protein-1 (bone morphogenetic protein-7) in the treatment of tibial nonunions \u2013 a prospective, randomized clinical trial comparing rhOP-1 with fresh bone autograft","volume":"83A","author":"Friedlaender","year":"2001","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2015.01.020_bib0190","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.13752","article-title":"Evolution of the internal fixation of long bone fractures \u2013 the scientific basis of biological internal fixation: choosing a new balance between stability and biology","volume":"84B","author":"Perren","year":"2002","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.injury.2015.01.020_bib0195","doi-asserted-by":"crossref","first-page":"900","DOI":"10.2106\/00004623-198870060-00015","article-title":"Treatment of open tibial-shaft fractures, external fixation and secondary intramedullary nailing","volume":"70A","author":"McGraw","year":"1988","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2015.01.020_bib0200","first-page":"206","article-title":"Delayed unions of the tibia","volume":"88A","author":"Phieffer","year":"2006","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2015.01.020_bib0205","doi-asserted-by":"crossref","first-page":"2567","DOI":"10.2106\/JBJS.G.01694","article-title":"Randomized trial of reamed and unreamed intramedullary nailing of tibial shaft fractures","volume":"90A","author":"Bhandari","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2015.01.020_bib0210","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1038\/35088122","article-title":"Anabolism \u2013 low mechanical signals strengthen long bones","volume":"412","author":"Rubin","year":"2001","journal-title":"Nature"},{"key":"10.1016\/j.injury.2015.01.020_bib0215","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/j.orthres.2003.11.007","article-title":"The influence of cyclic compression and distraction on the healing of experimental tibial fractures","volume":"22","author":"Hente","year":"2004","journal-title":"J Orthop Res"},{"key":"10.1016\/j.injury.2015.01.020_bib0220","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.2106\/00004623-198062080-00005","article-title":"Use of the Hoffmann apparatus in the treatment of unstable tibial fractures","volume":"62","author":"Lawyer","year":"1980","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2015.01.020_bib0225","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/00003086-200006000-00003","article-title":"The evolution of indirect reduction techniques for the treatment of fractures","author":"Leunig","year":"2000","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.injury.2015.01.020_bib0230","first-page":"79","article-title":"Biomechanical evaluation of the schuhli nut","author":"Kolodziej","year":"1998","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.injury.2015.01.020_bib0235","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1007\/s00402-009-0923-8","article-title":"Three-dimensional measurement of femoral antetorsion: comparison to a conventional radiological method","volume":"130","author":"Citak","year":"2010","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.injury.2015.01.020_bib0240","doi-asserted-by":"crossref","first-page":"25","DOI":"10.3233\/THC-2009-0529","article-title":"Rotational stability of femoral osteosynthesis in femoral fractures \u2013 navigated measurements","volume":"17","author":"Citak","year":"2009","journal-title":"Technol. Health Care: Off J Eur Soc Eng Med"},{"key":"10.1016\/j.injury.2015.01.020_bib0245","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1097\/01.ta.0000230282.65606.81","article-title":"Limb malalignment and functional outcome after antegrade versus retrograde intramedullary nailing in distal femoral fractures","volume":"61","author":"Salem","year":"2006","journal-title":"J Trauma \u2013 Inj Infec Crit Care"},{"key":"10.1016\/j.injury.2015.01.020_bib0250","doi-asserted-by":"crossref","first-page":"1346","DOI":"10.1016\/j.injury.2011.06.023","article-title":"Navigation in femoral-shaft fractures-from lab tests to clinical routine","volume":"42","author":"Wilharm","year":"2011","journal-title":"Injury \u2013 Int J Care Inj"},{"key":"10.1016\/j.injury.2015.01.020_bib0255","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1002\/rcs.351","article-title":"Functional assessment of a surgical robot for reduction of lower limb fractures","volume":"6","author":"Hung","year":"2010","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"10.1016\/j.injury.2015.01.020_bib0260","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1002\/rcs.417","article-title":"Novel 3D hexapod computer-assisted orthopaedic surgery system for closed diaphyseal fracture reduction","volume":"8","author":"Peifu","year":"2012","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"10.1016\/j.injury.2015.01.020_bib0265","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1002\/rcs.81","article-title":"A surgical telemanipulator for femur shaft fracture reduction","volume":"2","author":"Westphal","year":"2006","journal-title":"Int J Med RobotComput Assist Surg"},{"key":"10.1016\/j.injury.2015.01.020_bib0270","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1002\/rcs.240","article-title":"Conception of a navigation system controlling diaphyseal fracture reduction treated with external fixation","volume":"5","author":"Leloup","year":"2009","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"10.1016\/j.injury.2015.01.020_bib0275","doi-asserted-by":"crossref","first-page":"102","DOI":"10.2106\/JBJS.H.01286","article-title":"Navigated long-bone fracture reduction","volume":"91A","author":"Kahler","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2015.01.020_bib0280","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1016\/j.injury.2011.08.020","article-title":"Computer navigation in the reduction and fixation of femoral shaft fractures: a randomized control study","volume":"43","author":"Keast-Butler","year":"2012","journal-title":"Injury \u2013 Int J Care Inj"},{"key":"10.1016\/j.injury.2015.01.020_bib0285","doi-asserted-by":"crossref","first-page":"1746","DOI":"10.2106\/00004623-200111000-00020","article-title":"Surgeon's preferences for the operative treatment of fractures of the tibial shaft \u2013 an international survey","volume":"83A","author":"Bhandari","year":"2001","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2015.01.020_bib0290","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/S0268-0890(03)00068-9","article-title":"(iii) External fixation of diaphyseal fractures of the tibia","volume":"17","author":"Checketts","year":"2003","journal-title":"Curr Orthop"},{"key":"10.1016\/j.injury.2015.01.020_bib0295","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1097\/00005131-200309000-00002","article-title":"Correction of tibial malunion and nonunion with six-axis analysis deformity correction using the Taylor spatial frame","volume":"17","author":"Feldman","year":"2003","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2015.01.020_bib0300","doi-asserted-by":"crossref","first-page":"2104","DOI":"10.1016\/j.jbiomech.2005.06.002","article-title":"Development and validation of a new approach for computer-aided long bone fracture reduction using unilateral external fixator","volume":"39","author":"Koo","year":"2006","journal-title":"J Biomech"},{"key":"10.1016\/j.injury.2015.01.020_bib0305","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1016\/j.mattod.2013.11.017","article-title":"Bone tissue engineering using 3D printing","volume":"16","author":"Bose","year":"2013","journal-title":"Mater Today"},{"key":"10.1016\/j.injury.2015.01.020_bib0310","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1053\/j.jfas.2012.01.014","article-title":"A novel combination of printed 3-dimensional anatomic templates and computer-assisted surgical simulation for virtual preoperative planning in charcot foot reconstruction","volume":"51","author":"Giovinco","year":"2012","journal-title":"J Foot Ankle Surg"},{"key":"10.1016\/j.injury.2015.01.020_bib0315","first-page":"50","article-title":"Mechanical evaluation of external fixators used in limb lengthening","author":"Paley","year":"1990","journal-title":"Orthop Relat Res"},{"key":"10.1016\/j.injury.2015.01.020_bib0320","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1097\/00003086-200402000-00041","article-title":"Effect of weightbearing on bone formation during distraction osteogenesis","author":"Leung","year":"2004","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.injury.2015.01.020_bib0325","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1016\/j.measurement.2010.01.017","article-title":"A cross-target-based accurate calibration method of binocular stereo systems with large-scale field-of-view","volume":"43","author":"Xiao","year":"2010","journal-title":"Measurement"},{"key":"10.1016\/j.injury.2015.01.020_bib0330","first-page":"109","article-title":"Complications of external skeletal fixation","author":"Green","year":"1983","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.injury.2015.01.020_bib0335","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/S0020-1383(97)00025-9","article-title":"Fracture of the tibial diaphysis treated by external fixation and the axial alignment grid: a single surgeon's experience","volume":"28","author":"Hay","year":"1997","journal-title":"Injury-Int J Care Inj"},{"key":"10.1016\/j.injury.2015.01.020_bib0340","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/00005373-199302000-00001","article-title":"Effects of axial dynamization on bone healing","volume":"34","author":"Egger","year":"1993","journal-title":"J Trauma \u2013 Inj Infect Crit Care"},{"key":"10.1016\/j.injury.2015.01.020_bib0345","doi-asserted-by":"crossref","first-page":"1514","DOI":"10.2106\/00004623-200209000-00002","article-title":"Femoral intramedullary nailing: comparison of fracture-table and manual traction \u2013 a prospective, randomized study","volume":"84A","author":"Stephen","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2015.01.020_bib0350","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1097\/00005131-200408000-00002","article-title":"Rotational malalignment after intramedullary nailing of femoral fractures","volume":"18","author":"Jaarsma","year":"2004","journal-title":"J Orthop Trauma"}],"container-title":["Injury"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138315000248?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138315000248?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,8,29]],"date-time":"2020-08-29T14:32:08Z","timestamp":1598711528000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0020138315000248"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,6]]},"references-count":35,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2015,6]]}},"alternative-id":["S0020138315000248"],"URL":"https:\/\/doi.org\/10.1016\/j.injury.2015.01.020","relation":{},"ISSN":["0020-1383"],"issn-type":[{"value":"0020-1383","type":"print"}],"subject":[],"published":{"date-parts":[[2015,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Application of 3D printed customized external fixator in fracture reduction","name":"articletitle","label":"Article Title"},{"value":"Injury","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.injury.2015.01.020","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}