{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T12:00:23Z","timestamp":1790769623351,"version":"4.1.0"},"reference-count":17,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2016,8,1]],"date-time":"2016-08-01T00:00:00Z","timestamp":1470009600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","injuryjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Injury"],"published-print":{"date-parts":[[2016,8]]},"DOI":"10.1016\/j.injury.2016.03.014","type":"journal-article","created":{"date-parts":[[2016,3,17]],"date-time":"2016-03-17T20:00:54Z","timestamp":1458244854000},"page":"1676-1684","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":67,"title":["Fixation of displaced femoral neck fractures in young adults: Fixed-angle devices or Pauwel screws?"],"prefix":"10.1016","volume":"47","author":[{"given":"C.M.","family":"Hoshino","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.W.","family":"Christian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.V.","family":"O\u2019Toole","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.T.","family":"Manson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.injury.2016.03.014_bib0090","doi-asserted-by":"crossref","first-page":"837","DOI":"10.2106\/00004623-198466060-00003","article-title":"Fractures of the femoral neck in patients between the ages of twelve and forty-nine years","volume":"66","author":"Swiontkowski","year":"1984","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2016.03.014_bib0095","doi-asserted-by":"crossref","first-page":"1711","DOI":"10.2106\/00004623-200408000-00015","article-title":"Operative treatment of femoral neck fractures in patients between the ages of fifteen and fifty years","volume":"86","author":"Haidukewych","year":"2004","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2016.03.014_bib0100","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1097\/00003086-199910000-00037","article-title":"Vertical shear fractures of the femoral neck: a biomechanical study","volume":"367","author":"Baitner","year":"1999","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.injury.2016.03.014_bib0105","first-page":"256","article-title":"Basicervical fractures of the proximal femur: a biomechanical study of 3 internal fixation techniques","volume":"306","author":"Blair","year":"1994","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.injury.2016.03.014_bib0110","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1302\/0301-620X.72B5.2211759","article-title":"Femoral neck fracture fixation: comparison of a sliding screw with lag screws","volume":"72","author":"Clark","year":"1990","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.injury.2016.03.014_bib0115","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1097\/BOT.0b013e31814b822e","article-title":"Vertically oriented femoral neck fractures: mechanical analysis of four fixation techniques","volume":"21","author":"Aminian","year":"2007","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2016.03.014_bib0120","doi-asserted-by":"crossref","first-page":"138","DOI":"10.3109\/17453679809117614","article-title":"Choice of implants for internal fixation of femoral neck fractures: meta-analysis of 25 randomised trials including 4,925 patients","volume":"69","author":"Parker","year":"1998","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.injury.2016.03.014_bib0125","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.2106\/JBJS.G.01353","article-title":"Results of internal fixation of Pauwels type-3 vertical femoral neck fractures","volume":"90","author":"Liporace","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2016.03.014_bib0130","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1097\/BOT.0b013e318176191f","article-title":"Optimal internal fixation for femoral neck fractures: multiple screws or sliding hip screws?","volume":"23","author":"Bhandari","year":"2009","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2016.03.014_bib0135","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1002\/jor.1100050316","article-title":"Torsion and bending analysis of internal fixation techniques for femoral neck fractures: the role of implant design and bone density","volume":"5","author":"Swiontkowski","year":"1987","journal-title":"J Orthop Res"},{"key":"10.1016\/j.injury.2016.03.014_bib0140","doi-asserted-by":"crossref","first-page":"886","DOI":"10.1016\/j.clinbiomech.2013.08.007","article-title":"Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures?","volume":"28","author":"Hawks","year":"2013","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"Suppl. 10","key":"10.1016\/j.injury.2016.03.014_bib0145","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","article-title":"Fracture and dislocation classification compendium: 2007: Orthopaedic Trauma Association classification, database and outcomes committee","volume":"21","author":"Marsh","year":"2007","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2016.03.014_bib0150","first-page":"142","article-title":"Predictable healing of femoral neck fractures treated with intraoperative compression and length-stable implants","volume":"69","author":"Boraiah","year":"2010","journal-title":"J Trauma"},{"key":"10.1016\/j.injury.2016.03.014_bib0155","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1302\/0301-620X.73B5.1894675","article-title":"Intracapsular fractures of the neck of femur: parallel or crossed garden screws?","volume":"73","author":"Parker","year":"1991","journal-title":"J Bone Joint Surg Br"},{"issue":"Suppl. 1","key":"10.1016\/j.injury.2016.03.014_bib0160","doi-asserted-by":"crossref","first-page":"S76","DOI":"10.1016\/j.injury.2013.10.026","article-title":"Angular stable multiple screw fixation (Targon FN) versus standard SHS for the fixation of femoral neck fractures","volume":"45","author":"Eschler","year":"2014","journal-title":"Injury"},{"key":"10.1016\/j.injury.2016.03.014_bib0165","first-page":"163","article-title":"Femoral neck shortening after fracture fixation with multiple cancellous screws: incidence and effect on function","volume":"64","author":"Zlowodzki","year":"2008","journal-title":"J Trauma"},{"key":"10.1016\/j.injury.2016.03.014_bib0170","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1302\/0301-620X.90B11.20582","article-title":"The effect of shortening and varus collapse of the femoral neck on function after fixation of intracapsular fracture of the hip: a multi-centre cohort study","volume":"90","author":"Zlowodzki","year":"2008","journal-title":"J Bone Joint Surg Br"}],"container-title":["Injury"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138316300419?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138316300419?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2021,4,3]],"date-time":"2021-04-03T19:44:04Z","timestamp":1617479044000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0020138316300419"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,8]]},"references-count":17,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2016,8]]}},"alternative-id":["S0020138316300419"],"URL":"https:\/\/doi.org\/10.1016\/j.injury.2016.03.014","relation":{},"ISSN":["0020-1383"],"issn-type":[{"value":"0020-1383","type":"print"}],"subject":[],"published":{"date-parts":[[2016,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Fixation of displaced femoral neck fractures in young adults: Fixed-angle devices or Pauwel screws?","name":"articletitle","label":"Article Title"},{"value":"Injury","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.injury.2016.03.014","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}]}}