{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T10:44:08Z","timestamp":1786445048490,"version":"build-2736575974"},"reference-count":37,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2018,10,1]],"date-time":"2018-10-01T00:00:00Z","timestamp":1538352000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","injuryjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Injury"],"published-print":{"date-parts":[[2018,10]]},"DOI":"10.1016\/j.injury.2018.06.023","type":"journal-article","created":{"date-parts":[[2018,6,22]],"date-time":"2018-06-22T13:52:38Z","timestamp":1529675558000},"page":"1810-1815","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":18,"title":["Volar plating in distal radius fractures: A prospective clinical study on efficacy of dorsal tangential views to avoid screw penetration"],"prefix":"10.1016","volume":"49","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5053-8261","authenticated-orcid":false,"given":"Minke","family":"Bergsma","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Job N.","family":"Doornberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robin","family":"Duit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aimane","family":"Saarig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Worsley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruurd","family":"Jaarsma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"9","key":"10.1016\/j.injury.2018.06.023_bib0005","doi-asserted-by":"crossref","first-page":"1855","DOI":"10.2106\/JBJS.G.01569","article-title":"Fractures of the distal part of the radius. The evolution of practice over time. Where's the evidence?","volume":"90","author":"Koval","year":"2008","journal-title":"J Bone Jt Surg Am"},{"issue":"10","key":"10.1016\/j.injury.2018.06.023_bib0010","doi-asserted-by":"crossref","first-page":"3098","DOI":"10.1007\/s11999-015-4335-5","article-title":"Clinical faceoff: controversies in the management of distal radius fractures","volume":"473","author":"Kakar","year":"2015","journal-title":"Clin Orthop Relat Res"},{"issue":"9","key":"10.1016\/j.injury.2018.06.023_bib0015","doi-asserted-by":"crossref","first-page":"566","DOI":"10.5435\/JAAOS-22-09-566","article-title":"Controversies in the management of distal radius fractures","volume":"22","author":"Koval","year":"2014","journal-title":"J Am Acad Orthop Surg"},{"key":"10.1016\/j.injury.2018.06.023_bib0020","doi-asserted-by":"crossref","unstructured":"Members of the Writing Review, and Voting Panels of the AUC on the Treatment of Distal Radius Fractures, Watters WC, Sanders JO, Murray J, Patel N. The American Academy of Orthopaedic Surgeons Appropriate Use Criteria on the treatment of distal radius fractures. J Bone Joint Surg Am. 2014;96(2):160-161.","DOI":"10.2106\/JBJS.M.01314"},{"issue":"8","key":"10.1016\/j.injury.2018.06.023_bib0025","doi-asserted-by":"crossref","first-page":"502","DOI":"10.5435\/JAAOS-21-08-502","article-title":"Treatment of distal radius fractures","volume":"21","author":"Murray","year":"2013","journal-title":"J Am Acad Orthop Surg"},{"issue":"7","key":"10.1016\/j.injury.2018.06.023_bib0030","doi-asserted-by":"crossref","first-page":"1414","DOI":"10.1016\/j.jhsa.2013.04.019","article-title":"Dorsal locked plate fixation of distal radius fractures","volume":"38","author":"Lutsky","year":"2013","journal-title":"J Hand Surg Am"},{"issue":"3","key":"10.1016\/j.injury.2018.06.023_bib0035","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.hcl.2005.02.001","article-title":"Dorsal plating for distal radius fractures","volume":"21","author":"Tavakolian","year":"2005","journal-title":"Hand Clin"},{"issue":"5","key":"10.1016\/j.injury.2018.06.023_bib0040","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1097\/BOT.0b013e318059b993","article-title":"Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate","volume":"21","author":"Arora","year":"2007","journal-title":"J Orthop Trauma"},{"issue":"8","key":"10.1016\/j.injury.2018.06.023_bib0045","doi-asserted-by":"crossref","first-page":"1837","DOI":"10.2106\/JBJS.H.01478","article-title":"Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial","volume":"91","author":"Rozental","year":"2009","journal-title":"J Bone Jt Surg Am"},{"issue":"12","key":"10.1016\/j.injury.2018.06.023_bib0050","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1097\/BOT.0b013e3182913fc5","article-title":"Volar plate fixation for the treatment of distal radius fractures: analysis of adverse events","volume":"27","author":"Tarallo","year":"2013","journal-title":"J Orthop Trauma"},{"issue":"10","key":"10.1016\/j.injury.2018.06.023_bib0055","doi-asserted-by":"crossref","first-page":"e408","DOI":"10.1097\/BOT.0000000000000361","article-title":"Dorsal screw penetration with the use of volar plating of distal radius fractures: how can you best detect?","volume":"29","author":"Hill","year":"2015","journal-title":"J Orthop Trauma"},{"issue":"5","key":"10.1016\/j.injury.2018.06.023_bib0060","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1016\/j.jhsa.2012.02.026","article-title":"Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius","volume":"37","author":"Ozer","year":"2012","journal-title":"J Hand Surg Am"},{"issue":"3","key":"10.1016\/j.injury.2018.06.023_bib0065","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1007\/s11552-007-9038-2","article-title":"Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study","volume":"2","author":"Maschke","year":"2007","journal-title":"Hand (N Y)"},{"issue":"8","key":"10.1016\/j.injury.2018.06.023_bib0070","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1302\/0301-620X.95B8.31301","article-title":"A new radiological method to detect dorsally penetrating screws when using volar locking plates in distal radial fractures. The dorsal horizon view","volume":"95-b","author":"Haug","year":"2013","journal-title":"Bone Jt J"},{"key":"10.1016\/j.injury.2018.06.023_bib0075","doi-asserted-by":"crossref","first-page":"1402517","DOI":"10.1155\/2017\/1402517","article-title":"Comparing dorsal tangential and lateral views of the wrist for detecting dorsal screw penetration after volar plating of distal radius fractures","volume":"2017","author":"Giugale","year":"2017","journal-title":"Adv Orthop"},{"issue":"6","key":"10.1016\/j.injury.2018.06.023_bib0080","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1111\/1755-0998.12520","article-title":"Detecting and quantifying introgression in hybridized populations: simplifying assumptions yield overconfidence and uncertainty","volume":"16","author":"Della Croce","year":"2016","journal-title":"Mol Ecol Resour"},{"issue":"11","key":"10.1016\/j.injury.2018.06.023_bib0085","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1097\/BOT.0000000000000661","article-title":"The detection of prominent hardware in volar locked plating of distal radius fractures: intraoperative fluoroscopy versus computed tomography","volume":"30","author":"Ganesh","year":"2016","journal-title":"J Orthop Trauma"},{"issue":"1","key":"10.1016\/j.injury.2018.06.023_bib0090","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.jhsa.2014.10.021","article-title":"The dorsal tangential X-ray view to determine dorsal screw penetration during volar plating of distal radius fractures","volume":"40","author":"Brunner","year":"2015","journal-title":"J Hand Surg Am"},{"issue":"2","key":"10.1016\/j.injury.2018.06.023_bib0095","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1007\/s11552-010-9316-2","article-title":"Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating","volume":"6","author":"Ozer","year":"2011","journal-title":"Hand (N Y)"},{"issue":"10","key":"10.1016\/j.injury.2018.06.023_bib0100","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1016\/j.jhsa.2011.07.020","article-title":"The dorsal horizon view: detecting screw protrusion at the distal radius","volume":"36","author":"Joseph","year":"2011","journal-title":"J Hand Surg Am"},{"issue":"2","key":"10.1016\/j.injury.2018.06.023_bib0105","doi-asserted-by":"crossref","first-page":"e24622","DOI":"10.5812\/atr.4(2)2015.24622","article-title":"Tangential view and intraoperative three-dimensional fluoroscopy for the detection of screw-misplacements in volar plating of distal radius fractures","volume":"4","author":"Rausch","year":"2015","journal-title":"Arch Trauma Res"},{"issue":"3","key":"10.1016\/j.injury.2018.06.023_bib0110","first-page":"183","article-title":"Distal radius skyline view: how to prevent dorsal cortical penetration","volume":"26","author":"Taylor","year":"2017","journal-title":"J Surg Orthop Adv"},{"issue":"4","key":"10.1016\/j.injury.2018.06.023_bib0115","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/0020-1383(89)90113-7","article-title":"Stability assessment of distal radius fractures","volume":"20","author":"Lafontaine","year":"1989","journal-title":"Injury"},{"issue":"7","key":"10.1016\/j.injury.2018.06.023_bib0120","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1177\/1753193413517806","article-title":"Comparative clinica; Study of locking screws versus smooth locking pegs in volar plating of distal radius fractures","volume":"39","author":"Boretto","year":"2013","journal-title":"J Hand Surg Eur Vol"},{"issue":"10 Suppl","key":"10.1016\/j.injury.2018.06.023_bib0125","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","article-title":"Fracture and dislocation classification compendium-2007: orthopaedic trauma association classification, database and outcomes committee","volume":"21","author":"Marsh","year":"2007","journal-title":"J Orthop Trauma"},{"issue":"3","key":"10.1016\/j.injury.2018.06.023_bib0130","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1142\/S0218810408004055","article-title":"Delayed rupture of extensor digitorum communis tendon following volar plating of distal radius fracture","volume":"13","author":"Hattori","year":"2008","journal-title":"Hand Surg"},{"issue":"12","key":"10.1016\/j.injury.2018.06.023_bib0135","doi-asserted-by":"crossref","first-page":"1610","DOI":"10.1302\/0301-620X.88B12.17696","article-title":"Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures","volume":"88","author":"Al-Rashid","year":"2006","journal-title":"J Bone Jt Surg Br"},{"issue":"6","key":"10.1016\/j.injury.2018.06.023_bib0140","doi-asserted-by":"crossref","first-page":"369","DOI":"10.5435\/00124635-200906000-00005","article-title":"Complications of volar plate fixation for managing distal radius fractures","volume":"17","author":"Berglund","year":"2009","journal-title":"J Am Acad Orthop Surg"},{"issue":"4","key":"10.1016\/j.injury.2018.06.023_bib0145","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1007\/s11552-014-9616-z","article-title":"Intraoperative evaluation of dorsal screw prominence after polyaxial volar plate fixation of distal radius fractures utilizing the Hoya view: a cadaveric study","volume":"9","author":"Dolce","year":"2014","journal-title":"Hand (N Y)"},{"issue":"9","key":"10.1016\/j.injury.2018.06.023_bib0150","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1007\/s00402-011-1300-y","article-title":"Dorsal screw penetration following implant removal after volar locked plating of distal radius fracture","volume":"131","author":"Haug","year":"2011","journal-title":"Arch Orthop Trauma Surg"},{"issue":"7","key":"10.1016\/j.injury.2018.06.023_bib0155","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1016\/j.jhsa.2011.04.004","article-title":"Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study","volume":"36","author":"Yu","year":"2011","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.injury.2018.06.023_bib0160","article-title":"Detecting dorsal screw penetration following volar plate fixation of the distal radius\u2013A validation study in a saw bone model","author":"Poole","year":"2016","journal-title":"Trauma"},{"issue":"5","key":"10.1016\/j.injury.2018.06.023_bib0165","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1177\/1753193411426809","article-title":"Accuracy of the skyline view for detecting dorsal cortical penetration during volar distal radius fixation","volume":"37","author":"Riddick","year":"2012","journal-title":"J Hand Surg Eur Vol"},{"issue":"3","key":"10.1016\/j.injury.2018.06.023_bib0170","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1016\/j.jhsa.2015.12.020","article-title":"Using ultrasound to prevent screw penetration","volume":"41","author":"Balfour","year":"2016","journal-title":"J Hand Surg Am"},{"issue":"12","key":"10.1016\/j.injury.2018.06.023_bib0175","doi-asserted-by":"crossref","first-page":"2646","DOI":"10.1016\/j.jhsa.2012.10.018","article-title":"Screw prominence of locking plating in distal radius fractures","volume":"37","author":"S\u00fcg\u00fcn","year":"2012","journal-title":"J Hand Surg Am"},{"issue":"5","key":"10.1016\/j.injury.2018.06.023_bib0180","doi-asserted-by":"crossref","first-page":"199","DOI":"10.2214\/AJR.08.1057","article-title":"Screw impingement on the extensor tendons in distal radius fractures treated by volar plating: sonographic appearance","volume":"191","author":"Bianchi","year":"2008","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"10.1016\/j.injury.2018.06.023_bib0185","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1016\/j.aott.2017.10.004","article-title":"Comparison of ultrasound and dorsal horizon radiographic view for the detection of dorsal screw penetration","volume":"51","author":"G\u00fcrb\u00fcz","year":"2017","journal-title":"Acta Orthop Traumatol Turc"}],"container-title":["Injury"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138318302900?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138318302900?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,10,19]],"date-time":"2019-10-19T17:54:10Z","timestamp":1571507650000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0020138318302900"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10]]},"references-count":37,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2018,10]]}},"alternative-id":["S0020138318302900"],"URL":"https:\/\/doi.org\/10.1016\/j.injury.2018.06.023","relation":{},"ISSN":["0020-1383"],"issn-type":[{"value":"0020-1383","type":"print"}],"subject":[],"published":{"date-parts":[[2018,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Volar plating in distal radius fractures: A prospective clinical study on efficacy of dorsal tangential views to avoid screw penetration","name":"articletitle","label":"Article Title"},{"value":"Injury","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.injury.2018.06.023","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}]}}