{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T01:53:38Z","timestamp":1775267618728,"version":"3.50.1"},"reference-count":11,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2019,2,1]],"date-time":"2019-02-01T00:00:00Z","timestamp":1548979200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","injuryjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Injury"],"published-print":{"date-parts":[[2019,2]]},"DOI":"10.1016\/j.injury.2018.11.019","type":"journal-article","created":{"date-parts":[[2018,11,12]],"date-time":"2018-11-12T02:39:39Z","timestamp":1541990379000},"page":"541-545","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accidental external rotation of distal interlock jig in retrograde femoral nailing can lead to more prominent screws"],"prefix":"10.1016","volume":"50","author":[{"given":"Boshen","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shea M.","family":"Comadoll","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph R.","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul E.","family":"Matuszewski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"9","key":"10.1016\/j.injury.2018.11.019_bib0005","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1097\/BOT.0b013e318206cd06","article-title":"Use of femoral shaft fracture classification for predicting the risk of associated injuries","volume":"25","author":"Nikolaou","year":"2011","journal-title":"J Orthop Trauma"},{"issue":"6","key":"10.1016\/j.injury.2018.11.019_bib0010","first-page":"325","article-title":"Knee pain and leg-length discrepancy after retrograde femoral nailing","volume":"36","author":"Reina","year":"2007","journal-title":"Am J Orthop"},{"issue":"March","key":"10.1016\/j.injury.2018.11.019_bib0015","doi-asserted-by":"crossref","DOI":"10.1016\/B978-0-323-03424-1.10015-4","article-title":"Retrograde Versus Antegrade Nailing of Femoral Shaft Fractures","author":"Ricci","year":"2008","journal-title":"J Orthop Trauma"},{"issue":"Suppl. 9","key":"10.1016\/j.injury.2018.11.019_bib0020","first-page":"4","article-title":"Retrograde nailing for subtrochanteric femur fractures","volume":"29","author":"DiCicco","year":"2000","journal-title":"Am J Orthop (Belle Mead NJ)"},{"issue":"5","key":"10.1016\/j.injury.2018.11.019_bib0025","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1302\/0301-620X.82B5.10038","article-title":"Antegrade or retrograde reamed femoral nailing","volume":"82","author":"Tornetta","year":"2000","journal-title":"J Bone Jt Surg"},{"issue":"5","key":"10.1016\/j.injury.2018.11.019_bib0030","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1302\/0301-620X.88B5.16875","article-title":"Incidence and aetiology of anterior knee pain after intramedullary nailing of the femur and tibia","volume":"88-B","author":"Katsoulis","year":"2006","journal-title":"J Bone Joint Surg Br"},{"issue":"2","key":"10.1016\/j.injury.2018.11.019_bib0035","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1097\/00005131-200302000-00004","article-title":"Optimal entry point for retrograde femoral nailing","volume":"17","author":"Krupp","year":"2003","journal-title":"J Orthop Trauma"},{"issue":"320","key":"10.1016\/j.injury.2018.11.019_bib0040","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1097\/00003086-199511000-00015","article-title":"Injury to infrapatellar branch of saphenous nerve in arthroscopic knee surgery","author":"Mochida","year":"1995","journal-title":"Clin Orthop Relat Res"},{"issue":"24","key":"10.1016\/j.injury.2018.11.019_bib0045","doi-asserted-by":"crossref","first-page":"3352","DOI":"10.4103\/0366-6999.171441","article-title":"Femoral Condyles Tangential Views: An Effective Method to Detect the Screw Penetration of Femoral Condyles After Retrograde Nailing","volume":"128","author":"Zheng","year":"2015","journal-title":"Chin Med J"},{"issue":"3","key":"10.1016\/j.injury.2018.11.019_bib0050","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1016\/j.injury.2017.01.015","article-title":"Radiographic predictors of symptomatic screw removal after retrograde femoral nail insertion","volume":"48","author":"Hamaker","year":"2017","journal-title":"Injury"},{"key":"10.1016\/j.injury.2018.11.019_bib0055","first-page":"13","article-title":"Incidence of Intramedullary Nail Removal After Femoral Shaft Fracture Healing","volume":"50","author":"Hui","year":"2007","journal-title":"Can J Surg"}],"container-title":["Injury"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138318306843?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138318306843?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T01:06:14Z","timestamp":1775264774000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0020138318306843"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2]]},"references-count":11,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,2]]}},"alternative-id":["S0020138318306843"],"URL":"https:\/\/doi.org\/10.1016\/j.injury.2018.11.019","relation":{},"ISSN":["0020-1383"],"issn-type":[{"value":"0020-1383","type":"print"}],"subject":[],"published":{"date-parts":[[2019,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Accidental external rotation of distal interlock jig in retrograde femoral nailing can lead to more prominent screws","name":"articletitle","label":"Article Title"},{"value":"Injury","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.injury.2018.11.019","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}