{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T22:21:09Z","timestamp":1762899669699},"reference-count":8,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2019,2,1]],"date-time":"2019-02-01T00:00:00Z","timestamp":1548979200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","injuryjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Injury"],"published-print":{"date-parts":[[2019,2]]},"DOI":"10.1016\/j.injury.2018.12.017","type":"journal-article","created":{"date-parts":[[2018,12,16]],"date-time":"2018-12-16T01:05:37Z","timestamp":1544922337000},"page":"256-262","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"title":["Biomechanical evaluation of a transcondylar screw from the dorsolateral plate support on the stabilization of orthogonal plate configuration in distal humeral fracture"],"prefix":"10.1016","volume":"50","author":[{"given":"Akira","family":"Hara","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshiya","family":"Kudo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Ichihara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hideaki","family":"Iwase","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"Nagao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuichiro","family":"Maruyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuo","family":"Kaneko","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.injury.2018.12.017_bib0005","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.jse.2004.09.033","article-title":"Optimizing stability in distal humeral fracture fixation","volume":"14","author":"O\u2019Driscoll","year":"2005","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.injury.2018.12.017_bib0010","doi-asserted-by":"crossref","first-page":"2071","DOI":"10.1016\/j.injury.2016.08.012","article-title":"Biomechanical properties of orthogonal plate configuration versus parallel plate configuration using the same locking plate system for intra-articular distal humeral fractures under radial or ulnar column axial load","volume":"47","author":"Kudo","year":"2016","journal-title":"Injury"},{"key":"10.1016\/j.injury.2018.12.017_bib0015","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1097\/BOT.0b013e31816edbce","article-title":"A biomechanical comparison of plate configuration in distal humerus fractures","volume":"22","author":"Arnander","year":"2008","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2018.12.017_bib0020","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jse.2010.08.005","article-title":"Biomechanical evaluation of parallel versus orthogonal plate fixation of intra-articular distal humerus fractures","volume":"20","author":"Zalavras","year":"2011","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.injury.2018.12.017_bib0025","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1002\/jor.20528","article-title":"Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures","volume":"26","author":"Stoffel","year":"2008","journal-title":"J Orthop Res"},{"key":"10.1016\/j.injury.2018.12.017_bib0030","doi-asserted-by":"crossref","first-page":"S73","DOI":"10.1007\/s00198-004-1764-5","article-title":"Distal humerus fracture in elderly patients: results after open reduction and internal fixation","volume":"16","author":"Korner","year":"2005","journal-title":"Osteoporos Int"},{"key":"10.1016\/j.injury.2018.12.017_bib0035","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.jse.2009.05.003","article-title":"A clinical comparison of two different double plating methods for intraarticular distal humerus fractures","volume":"19","author":"Shin","year":"2010","journal-title":"J Shoulder Elbow Surg"},{"key":"10.1016\/j.injury.2018.12.017_bib0040","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1016\/j.otsr.2013.02.004","article-title":"Promising results after the treatment of simple and complex distal humerus type C fractures by angular-stable double-plate osteosynthesis","volume":"99","author":"Schmidt","year":"2013","journal-title":"Orthop Traumatol Surg Res"}],"container-title":["Injury"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138318307514?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138318307514?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,4,25]],"date-time":"2019-04-25T20:12:25Z","timestamp":1556223145000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0020138318307514"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2]]},"references-count":8,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,2]]}},"alternative-id":["S0020138318307514"],"URL":"https:\/\/doi.org\/10.1016\/j.injury.2018.12.017","relation":{},"ISSN":["0020-1383"],"issn-type":[{"value":"0020-1383","type":"print"}],"subject":[],"published":{"date-parts":[[2019,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biomechanical evaluation of a transcondylar screw from the dorsolateral plate support on the stabilization of orthogonal plate configuration in distal humeral fracture","name":"articletitle","label":"Article Title"},{"value":"Injury","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.injury.2018.12.017","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}