{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T12:33:42Z","timestamp":1789043622970,"version":"build-2803163510"},"reference-count":29,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100007046","name":"Wuhan University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100007046","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","injuryjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Injury"],"published-print":{"date-parts":[[2020,2]]},"DOI":"10.1016\/j.injury.2019.09.037","type":"journal-article","created":{"date-parts":[[2019,10,18]],"date-time":"2019-10-18T11:27:21Z","timestamp":1571398041000},"page":"457-465","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Comparison of a modified technique with conventional tension-band using Cable Grip System for comminuted patella fractures"],"prefix":"10.1016","volume":"51","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9597-5542","authenticated-orcid":false,"given":"Xu","family":"Yang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiang","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhe","family":"Xie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.injury.2019.09.037_bib0001","doi-asserted-by":"crossref","first-page":"e96","DOI":"10.2106\/JBJS.L.00012","article-title":"Outcomes after operative fixation of complete articular patellar fractures: assessment of functional impairment","volume":"95","author":"Lazaro","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2019.09.037_bib0002","doi-asserted-by":"crossref","first-page":"377","DOI":"10.3928\/01477447-20150603-05","article-title":"Current treatment strategies for patella fractures","volume":"38","author":"Schuett","year":"2015","journal-title":"Orthopedics"},{"key":"10.1016\/j.injury.2019.09.037_bib0003","doi-asserted-by":"crossref","first-page":"e143","DOI":"10.1097\/BOT.0000000000001390","article-title":"Miniplate augmented tension-band wiring for comminuted patella fractures","volume":"33","author":"Cho","year":"2019","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2019.09.037_bib0004","doi-asserted-by":"crossref","first-page":"1974","DOI":"10.1016\/j.injury.2014.10.008","article-title":"Management of comminuted patellar fracture with non-absorbable suture cerclage and Nitinol patellar concentrator","volume":"45","author":"Lue","year":"2014","journal-title":"Injury"},{"key":"10.1016\/j.injury.2019.09.037_bib0005","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1016\/j.injury.2018.03.030","article-title":"Fixed angle plate fixation of comminuted patellar fractures","volume":"49","author":"Moore","year":"2018","journal-title":"Injury"},{"key":"10.1016\/j.injury.2019.09.037_bib0006","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1016\/j.knee.2010.02.005","article-title":"Management of displaced comminuted patellar fracture with titanium cable cerclage","volume":"17","author":"Yang","year":"2010","journal-title":"Knee"},{"key":"10.1016\/j.injury.2019.09.037_bib0007","doi-asserted-by":"crossref","first-page":"1613","DOI":"10.1016\/j.injury.2016.05.039","article-title":"Non-metallic implant for patellar fracture fixation: a systematic review","volume":"47","author":"Camarda","year":"2016","journal-title":"Injury"},{"key":"10.1016\/j.injury.2019.09.037_bib0008","doi-asserted-by":"crossref","first-page":"e66","DOI":"10.1097\/BOT.0000000000000686","article-title":"Revisiting tension band fixation for difficult patellar fractures","volume":"31","author":"Hambright","year":"2017","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2019.09.037_bib0009","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1007\/s00402-014-2071-z","article-title":"Locked tension band wiring using ring pins for patellar fractures: a method of minimising implant migration","volume":"134","author":"Kim","year":"2014","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.injury.2019.09.037_bib0010","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1016\/j.injury.2015.02.017","article-title":"Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: a biomechanical study","volume":"46","author":"Dickens","year":"2015","journal-title":"Injury"},{"key":"10.1016\/j.injury.2019.09.037_bib0011","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1007\/s10195-015-0359-6","article-title":"FiberWire tension band for patellar fractures","volume":"17","author":"Camarda","year":"2016","journal-title":"J Orthop Traumatol Off J Ital Soc Orthop Traumatol"},{"key":"10.1016\/j.injury.2019.09.037_bib0012","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S0020-1383(00)00170-4","article-title":"Clinical experience of patellar fracture fixation using metal wire or non-absorbable polyester \u2014 a study of 37 cases","volume":"32","author":"Gosal","year":"2001","journal-title":"Injury"},{"key":"10.1016\/j.injury.2019.09.037_bib0013","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1097\/00005131-199704000-00008","article-title":"Early complications in the operative treatment of patella fractures","volume":"11","author":"Smith","year":"1997","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2019.09.037_bib0014","doi-asserted-by":"crossref","first-page":"653","DOI":"10.2106\/JBJS.K.01549","article-title":"Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires","volume":"95","author":"Hoshino","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2019.09.037_bib0015","doi-asserted-by":"crossref","first-page":"2361","DOI":"10.1007\/s11999-013-2932-8","article-title":"Comparison of the cable pin system with conventional open surgery for transverse patella fractures","volume":"471","author":"Mao","year":"2013","journal-title":"Clin Orthop"},{"key":"10.1016\/j.injury.2019.09.037_bib0016","doi-asserted-by":"crossref","first-page":"e459","DOI":"10.1097\/BOT.0000000000000400","article-title":"Comparison of tension-band wiring with the cable pin system in patella fractures: a randomized prospective study","volume":"29","author":"Tian","year":"2015","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2019.09.037_bib0017","doi-asserted-by":"crossref","first-page":"e260","DOI":"10.1097\/BOT.0b013e318290f818","article-title":"Kirschner wire bending","volume":"27","author":"Firoozabadi","year":"2013","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2019.09.037_bib0018","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1007\/s00264-008-0602-3","article-title":"Anatomical and biomechanical evaluation of the tension band technique in patellar fractures","volume":"33","author":"Baran","year":"2009","journal-title":"Int Orthop"},{"key":"10.1016\/j.injury.2019.09.037_bib0019","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","article-title":"Fracture and dislocation classification compendium - 2007: orthopaedic trauma association classification, database and outcomes committee","volume":"21","author":"Marsh","year":"2007","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2019.09.037_bib0020","doi-asserted-by":"crossref","DOI":"10.1016\/j.injury.2017.07.013","article-title":"Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using cable grip system","author":"Yang","year":"2017","journal-title":"Injury"},{"key":"10.1016\/j.injury.2019.09.037_bib0021","doi-asserted-by":"crossref","first-page":"e265","DOI":"10.3928\/01477447-20140225-59","article-title":"Horizontal versus vertical orientation of the loop for tension band wiring of transverse patella fractures","volume":"37","author":"Lee","year":"2014","journal-title":"Orthopedics"},{"key":"10.1016\/j.injury.2019.09.037_bib0022","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.jcot.2015.03.009","article-title":"A novel technique of patella fracture fixation facilitating early mobilization and reducing re-operation rates","volume":"6","author":"Agarwala","year":"2015","journal-title":"J Clin Orthop Trauma"},{"key":"10.1016\/j.injury.2019.09.037_bib0023","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.injury.2011.01.025","article-title":"Double fixation of displaced patella fractures using bioabsorbable cannulated lag screws and braided polyester suture tension bands","volume":"42","author":"Qi","year":"2011","journal-title":"Injury"},{"key":"10.1016\/j.injury.2019.09.037_bib0024","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1097\/00005131-199711000-00005","article-title":"Open reduction internal fixation of displaced transverse patella fractures with figure-eight wiring through parallel cannulated compression screws","volume":"11","author":"Berg","year":"1997","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2019.09.037_bib0025","doi-asserted-by":"crossref","first-page":"1309","DOI":"10.1016\/j.injury.2013.06.024","article-title":"Transosseous suturing of patellar fractures with braided polyester \u2013 A prospective cohort with a matched historical control study","volume":"44","author":"Chen","year":"2013","journal-title":"Injury"},{"key":"10.1016\/j.injury.2019.09.037_bib0026","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1097\/00005131-199707000-00009","article-title":"Biomechanical evaluation of current patella fracture fixation techniques","volume":"11","author":"Carpenter","year":"1997","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2019.09.037_bib0027","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1007\/s00264-006-0238-0","article-title":"Tension-band wiring of transverse fractures of patella. The effect of site of wire twists and orientation of stainless steel wire loop: a biomechanical investigation","volume":"31","author":"John","year":"2007","journal-title":"Int Orthop"},{"key":"10.1016\/j.injury.2019.09.037_bib0028","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.knee.2008.06.005","article-title":"Migration to the popliteal fossa of broken wires from a fixed patellar fracture","volume":"15","author":"Choi","year":"2008","journal-title":"Knee"},{"key":"10.1016\/j.injury.2019.09.037_bib0029","doi-asserted-by":"crossref","first-page":"444","DOI":"10.3944\/AOTT.2013.2990","article-title":"Locking knee after intra-articular migration of broken patella tension band wire: an extraordinary intra-articular migration via pseudarthrosis line","volume":"47","author":"Wang","year":"2013","journal-title":"Acta Orthop Traumatol Turc"}],"container-title":["Injury"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138319305625?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138319305625?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,17]],"date-time":"2025-09-17T06:29:01Z","timestamp":1758090541000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0020138319305625"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2]]},"references-count":29,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["S0020138319305625"],"URL":"https:\/\/doi.org\/10.1016\/j.injury.2019.09.037","relation":{},"ISSN":["0020-1383"],"issn-type":[{"value":"0020-1383","type":"print"}],"subject":[],"published":{"date-parts":[[2020,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of a modified technique with conventional tension-band using Cable Grip System for comminuted patella fractures","name":"articletitle","label":"Article Title"},{"value":"Injury","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.injury.2019.09.037","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}