{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T11:27:15Z","timestamp":1793878035359,"version":"4.7.0"},"reference-count":37,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2020,8,1]],"date-time":"2020-08-01T00:00:00Z","timestamp":1596240000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,8,1]],"date-time":"2020-08-01T00:00:00Z","timestamp":1596240000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","injuryjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Injury"],"published-print":{"date-parts":[[2020,8]]},"DOI":"10.1016\/j.injury.2020.07.025","type":"journal-article","created":{"date-parts":[[2020,7,10]],"date-time":"2020-07-10T01:56:55Z","timestamp":1594346215000},"page":"S28-S33","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":29,"special_numbering":"S3","title":["3D - Navigated percutaneous screw fixation of pelvic ring injuries \u2013 a pilot study"],"prefix":"10.1016","volume":"51","author":[{"given":"Michela","family":"Florio","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7120-9624","authenticated-orcid":false,"given":"Luigi","family":"Capasso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandro","family":"Olivi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carla","family":"Vitiello","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Leone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Liuzza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.injury.2020.07.025_bib0001","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1016\/j.injury.2007.01.025","article-title":"Is there a role for percutaneous pelvic and acetabular reconstruction?","volume":"38","author":"Rommens","year":"2007","journal-title":"Injury"},{"key":"10.1016\/j.injury.2020.07.025_bib0002","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1302\/0301-620X.89B2.18551","article-title":"Percutaneous fixation of the pelvic ring: an update","volume":"89","author":"Giannoudis","year":"2007","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.injury.2020.07.025_bib0003","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1097\/00003086-200006000-00004","article-title":"Percutaneous fixation of pelvic ring disruptions","volume":"375","author":"Routt","year":"2000","journal-title":"Clin Orthop"},{"key":"10.1016\/j.injury.2020.07.025_bib0004","doi-asserted-by":"crossref","first-page":"SA33","DOI":"10.1016\/S0020-1383(01)00059-6","article-title":"Percutaneous management of unstable pelvic ring disruptions","volume":"32","author":"Barei","year":"2001","journal-title":"Injury"},{"key":"10.1016\/j.injury.2020.07.025_bib0005","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/00005131-199506000-00005","article-title":"Early results of percutaneous iliosacral screws placed with the patient in the supine position","volume":"9","author":"Routt","year":"1995","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2020.07.025_bib0006","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1097\/00005131-200209000-00009","article-title":"Maneuvering the retrograde medullary screw in pubic ramus fractures","volume":"16","author":"Mosheiff","year":"2002","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2020.07.025_bib0007","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1097\/00005373-199503000-00031","article-title":"Percutaneous iliosacral screw fixation: early treatment for unstable posterior pelvic ring disruptions","volume":"38","author":"Shuler","year":"1995","journal-title":"J Trauma"},{"key":"10.1016\/j.injury.2020.07.025_bib0008","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1097\/00005131-200202000-00008","article-title":"Percutaneous screw fixation of fractures of the iliac wing and fracture-dislocations of the sacro-iliac joint (OTA Types 61-B2.2 and 61-B2.3, or Young-Burgess lateral compression type II pelvic fractures)","volume":"16","author":"Starr","year":"2002","journal-title":"J Orthop Trauma"},{"issue":"3","key":"10.1016\/j.injury.2020.07.025_bib0009","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1097\/01.ta.0000200860.01931.9a","article-title":"Percutaneous placement of iliosacral screws for unstable pelvic ring inju- ries: comparison between one and two C-arm Xuoroscopic techniques","volume":"60","author":"Peng","year":"2006","journal-title":"J Trauma"},{"key":"10.1016\/j.injury.2020.07.025_bib0010","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1097\/01.blo.0000128644.46013.08","article-title":"Computer-guidance in percutaneous screw stabilization of the iliosacral joint","author":"Arand","year":"2004","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.injury.2020.07.025_bib0011","doi-asserted-by":"crossref","first-page":"1299","DOI":"10.1097\/01.TA.0000133573.53587.2E","article-title":"Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain","volume":"57","author":"Schep","year":"2004","journal-title":"J Trauma"},{"key":"10.1016\/j.injury.2020.07.025_bib0012","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1097\/01.brs.0000194788.45002.1b","article-title":"An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws","volume":"31","author":"Smith","year":"2006","journal-title":"Spine"},{"key":"10.1016\/j.injury.2020.07.025_bib0013","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1016\/j.spinee.2010.03.023","article-title":"Three- dimensional image-guided placement of S2 alar screws to adjunct or salvage lumbosacral fixation","volume":"10","author":"Nottmeier","year":"2010","journal-title":"Spine J"},{"key":"10.1016\/j.injury.2020.07.025_bib0014","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1007\/s00586-010-1683-4","article-title":"Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques","volume":"20","author":"Silbermann","year":"2011","journal-title":"Eur Spine J"},{"key":"10.1016\/j.injury.2020.07.025_bib0015","doi-asserted-by":"crossref","first-page":"S273","DOI":"10.1016\/j.otsr.2013.03.002","article-title":"Percutaneous iliosacral screw fixation in unstable pelvic ring lesions: the interest of O-arm CT-guided navigation","volume":"99S","author":"Coste","year":"2013","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.injury.2020.07.025_bib0016","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.jocn.2015.08.011","article-title":"Image-guided percutaneous internal fixation of sacral fracture","volume":"23","author":"Kinon","year":"2016","journal-title":"J Clin Neurosci"},{"key":"10.1016\/j.injury.2020.07.025_bib0017","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1177\/1938640014532130","article-title":"Evaluation of tarsal navicular stress frac- ture fixation using intraoperative O-arm computed tomography","volume":"7","author":"Hsu","year":"2014","journal-title":"Foot Ankle Spec"},{"issue":"1","key":"10.1016\/j.injury.2020.07.025_bib0018","first-page":"1","article-title":"Pelvic ring fractures: should they be fixed?","volume":"70","author":"Tile","year":"1988","journal-title":"J Bone Joint Surg (Br)."},{"key":"10.1016\/j.injury.2020.07.025_bib0019","doi-asserted-by":"crossref","first-page":"143","DOI":"10.5435\/00124635-199605000-00004","article-title":"Acute pelvic fractures: I. Causation and classification","volume":"4","author":"Tile","year":"1996","journal-title":"J Am Acad Orthop Surg"},{"key":"10.1016\/j.injury.2020.07.025_bib0020","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1097\/BOT.0b013e31809810e5","article-title":"Table-skeletal fixation as an adjunct to pelvic ring reduction","volume":"21","author":"Matta","year":"2007","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2020.07.025_bib0021","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1097\/BOT.0b013e3181a1407d","article-title":"Reduction of displaced pelvic ring disruptions using a pelvic reduction frame","volume":"23","author":"Lefaivre","year":"2009","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.injury.2020.07.025_bib0022","series-title":"SF-36 questionnaire for the health survey - Handbook for the german version of questionnaire","author":"Bullinger","year":"1998"},{"issue":"2","key":"10.1016\/j.injury.2020.07.025_bib0023","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1002\/acm2.12534","article-title":"Radiation dose and image quality comparison during spine surgery with two different, intraoperative 3D imaging navigation systems","volume":"20","author":"Nachabe","year":"2019","journal-title":"Appl Clin Med Phys"},{"issue":"2","key":"10.1016\/j.injury.2020.07.025_bib0024","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s00402-018-3055-1","article-title":"Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation","volume":"139","author":"Takao","year":"2019","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.injury.2020.07.025_bib0025","article-title":"Accuracy of navigated and conventional iliosacral screw placement in B- and C-type pelvic ring fractures","author":"Berger-Groch","year":"2018","journal-title":"Eur J Trauma Emerg Surg"},{"key":"10.1016\/j.injury.2020.07.025_bib0026","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1097\/00003086-200202000-00014","article-title":"Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws","volume":"395","author":"Hinsche","year":"2002","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.injury.2020.07.025_bib0027","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1097\/00003086-199608000-00023","article-title":"Proximity of iliosacral screws to neurovascular structures after internal fixation","volume":"329","author":"Templeman","year":"1996","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.injury.2020.07.025_bib0028","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1097\/00005373-200207000-00009","article-title":"Fluoroscopic positioning of sacroiliac screws in 88 patients","volume":"53","author":"van den Bosch","year":"2002","journal-title":"J Trauma"},{"key":"10.1016\/j.injury.2020.07.025_bib0029","doi-asserted-by":"crossref","first-page":"289","DOI":"10.3109\/10929089809148149","article-title":"Iliosacral screw insertion using computer-assisted CT image guidance: a laboratory study","volume":"3","author":"Barrick","year":"1998","journal-title":"Comput Aided Surg"},{"key":"10.1016\/j.injury.2020.07.025_bib0030","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1097\/00003086-199809000-00013","article-title":"Percutaneous iliosacral screw placement using image guided techniques","volume":"354","author":"Tonetti","year":"1998","journal-title":"Clin Orthop"},{"issue":"7","key":"10.1016\/j.injury.2020.07.025_bib0031","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1016\/j.otsr.2018.07.006","article-title":"Posterior pelvic ring fractures: intraoperative 3D-CT guided navigation for accurate positioning of sacro-iliac screws","volume":"104","author":"Ghisla","year":"2018","journal-title":"Orthop Traumatol Surg Res"},{"issue":"3","key":"10.1016\/j.injury.2020.07.025_bib0032","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1007\/s00590-017-2075-9","article-title":"Accuracy of screw fixation using the O-arm\u00ae and StealthStation\u00ae navigation system for unstable pelvic ring fractures","volume":"28","author":"Takeba","year":"2018","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"10.1016\/j.injury.2020.07.025_bib0033","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1186\/1471-2474-11-153","article-title":"2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries\u2013a case series","volume":"11","author":"Gras","year":"2010","journal-title":"BMC Musculoskelet Disord"},{"key":"10.1016\/j.injury.2020.07.025_bib0034","doi-asserted-by":"crossref","DOI":"10.1016\/j.injury.2018.05.027","article-title":"Accuracy of sacroiliac screw placement with and without intraoperative navigation and clinical application of the sacral dysmorphism score","author":"Teo","year":"2018","journal-title":"Injury"},{"key":"10.1016\/j.injury.2020.07.025_bib0035","doi-asserted-by":"crossref","first-page":"1115","DOI":"10.1007\/s00402-014-2022-8","article-title":"Anatomical conditions of the posterior pelvic ring regarding bisegmental transverse sacroiliac screw fixation: a 3D morphometric study of 125 pelvic CT datasets","volume":"134","author":"Radetzki","year":"2014","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.injury.2020.07.025_bib0036","first-page":"S37","article-title":"J. Improved Intraoperative Fluoroscopy for Pelvic and Acetabular Surgery","volume":"33","author":"Jr","year":"2019","journal-title":"Orthop Trauma"},{"issue":"1","key":"10.1016\/j.injury.2020.07.025_bib0037","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1007\/s11548-016-1465-5","article-title":"2D versus 3D fluoroscopy\u2010based navigation in posterior pelvic fixation: review of the literature on current technology","volume":"12","author":"Thakkar","year":"2017","journal-title":"Int J Comput Assist Radiol Surg"}],"updated-by":[{"DOI":"10.1016\/j.injury.2021.02.011","type":"erratum","label":"Erratum","source":"publisher","updated":{"date-parts":[[2021,4,1]],"date-time":"2021-04-01T00:00:00Z","timestamp":1617235200000}}],"container-title":["Injury"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138320306069?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138320306069?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T14:18:24Z","timestamp":1762179504000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0020138320306069"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8]]},"references-count":37,"alternative-id":["S0020138320306069"],"URL":"https:\/\/doi.org\/10.1016\/j.injury.2020.07.025","relation":{},"ISSN":["0020-1383"],"issn-type":[{"value":"0020-1383","type":"print"}],"subject":[],"published":{"date-parts":[[2020,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"3D - Navigated percutaneous screw fixation of pelvic ring injuries \u2013 a pilot study","name":"articletitle","label":"Article Title"},{"value":"Injury","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.injury.2020.07.025","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}