{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T10:10:50Z","timestamp":1793095850908,"version":"4.5.0"},"reference-count":33,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2021,8,1]],"date-time":"2021-08-01T00:00:00Z","timestamp":1627776000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,8,1]],"date-time":"2021-08-01T00:00:00Z","timestamp":1627776000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,3,22]],"date-time":"2021-03-22T00:00:00Z","timestamp":1616371200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","injuryjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Injury"],"published-print":{"date-parts":[[2021,8]]},"DOI":"10.1016\/j.injury.2021.03.040","type":"journal-article","created":{"date-parts":[[2021,3,21]],"date-time":"2021-03-21T09:59:09Z","timestamp":1616320749000},"page":"2126-2130","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Biomechanical comparison of different cerclage types in addition to an angle stable plate osteosynthesis of distal tibial fractures"],"prefix":"10.1016","volume":"52","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7080-3445","authenticated-orcid":false,"given":"Stefan","family":"F\u00f6rch","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9439-0016","authenticated-orcid":false,"given":"Sabrina","family":"Sandriesser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edgar","family":"Mayr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Falk","family":"Schr\u00f6dl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"von R\u00fcden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Augat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"6","key":"10.1016\/j.injury.2021.03.040_bib0001","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.1007\/s00264-016-3347-4","article-title":"History of internal fixation (part 1): early developments with wires and plates before World War II","volume":"41","author":"Hernigou","year":"2017","journal-title":"Int Orthop"},{"issue":"4","key":"10.1016\/j.injury.2021.03.040_bib0002","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1007\/s00590-014-1520-2","article-title":"Past and present of the use of cerclage wires in orthopedics","volume":"25","author":"Angelini","year":"2014","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"Suppl 2","key":"10.1016\/j.injury.2021.03.040_bib0003","doi-asserted-by":"crossref","first-page":"S51","DOI":"10.1016\/S0020-1383(16)47009-9","article-title":"Managing Vancouver B1 fractures by cerclage system compared to locking plate fixation - a biomechanical study","volume":"47","author":"Gordon","year":"2016","journal-title":"Injury"},{"issue":"8","key":"10.1016\/j.injury.2021.03.040_bib0004","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1007\/s00402-017-2722-y","article-title":"Subtrochanteric fractures in elderly people treated with intramedullary fixation: quality of life and complications following open reduction and cerclage wiring versus closed reduction","volume":"137","author":"Codesido","year":"2017","journal-title":"Arch Orthop Trauma Surg"},{"issue":"10","key":"10.1016\/j.injury.2021.03.040_bib0005","doi-asserted-by":"crossref","first-page":"1992","DOI":"10.1016\/j.injury.2015.07.001","article-title":"Subtrochanteric fracture: the effect of cerclage wire on fracture reduction and outcome","volume":"46","author":"Hoskins","year":"2015","journal-title":"Injury"},{"issue":"6","key":"10.1016\/j.injury.2021.03.040_bib0006","doi-asserted-by":"crossref","first-page":"689","DOI":"10.4103\/ortho.IJOrtho_269_18","article-title":"Monofilament cerclage wiring fixation with locking plates for distal femoral fracture: is it appropriate?","volume":"53","author":"Lee","year":"2019","journal-title":"Indian J Orthop"},{"key":"10.1016\/j.injury.2021.03.040_bib0007","article-title":"More than a reposition tool: additional wire cerclage leads to increased load to failure in plate osteosynthesis for supracondylar femoral shaft fractures","author":"Bliemel","year":"2020","journal-title":"Arch Orthop Trauma Surg"},{"issue":"1","key":"10.1016\/j.injury.2021.03.040_bib0008","first-page":"28","article-title":"Evaluation of cerclage wiring in the treatment of subtrochanteric fractures","volume":"86","author":"Fauconnier","year":"2020","journal-title":"Acta Orthop Belg"},{"key":"10.1016\/j.injury.2021.03.040_bib0009","doi-asserted-by":"crossref","DOI":"10.1007\/s00402-020-03713-y","article-title":"Metallosis after using distal fibular locking plate for lateral malleolar fractures: a retrospective study","author":"Park","year":"2021","journal-title":"Arch Orthop Trauma Surg"},{"issue":"3","key":"10.1016\/j.injury.2021.03.040_bib0010","doi-asserted-by":"crossref","first-page":"486","DOI":"10.3390\/jfb6030486","article-title":"Metal-on-Metal hip arthroplasty: a review of adverse reactions and patient management","volume":"6","author":"Drummond","year":"2015","journal-title":"J Funct Biomater"},{"issue":"3","key":"10.1016\/j.injury.2021.03.040_bib0011","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1007\/s00113-020-00847-x","article-title":"Impairment of the blood supply by cerclages: myth or reality?: An overview of the experimental study situation","volume":"124","author":"F\u00f6rch","year":"2020","journal-title":"Unfallchirurg"},{"issue":"4","key":"10.1016\/j.injury.2021.03.040_bib0012","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1016\/j.injury.2014.12.027","article-title":"Incidence and epidemiology of tibial shaft fractures","volume":"46","author":"Larsen","year":"2015","journal-title":"Injury"},{"issue":"9","key":"10.1016\/j.injury.2021.03.040_bib0013","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1007\/s00402-019-03193-9","article-title":"Weight-bearing restrictions reduce postoperative mobility in elderly hip fracture patients","volume":"139","author":"Pfeufer","year":"2019","journal-title":"Arch Orthop Trauma Surg"},{"issue":"11","key":"10.1016\/j.injury.2021.03.040_bib0014","doi-asserted-by":"crossref","first-page":"936","DOI":"10.2106\/JBJS.17.01222","article-title":"Inability of older adult patients with hip fracture to maintain postoperative weight-bearing restrictions","volume":"100","author":"Kammerlander","year":"2018","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2021.03.040_bib0015","article-title":"Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis","author":"Sandriesser","year":"2020","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"10","key":"10.1016\/j.injury.2021.03.040_bib0016","doi-asserted-by":"crossref","first-page":"1627","DOI":"10.1016\/j.injury.2019.06.034","article-title":"A review of metallic and non-metallic cerclage in orthopaedic surgery: is there still a place for metallic cerclage?","volume":"50","author":"Peeters","year":"2019","journal-title":"Injury"},{"key":"10.1016\/j.injury.2021.03.040_bib0017","article-title":"A tensionable suture-based cerclage is an alternative to stainless steel cerclage fixation for stabilization of a humeral osteotomy during shoulder arthroplasty","author":"Denard","year":"2020","journal-title":"J Am Acad Orthop Surg"},{"issue":"3","key":"10.1016\/j.injury.2021.03.040_bib0018","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1177\/1758573217735323","article-title":"Is suture comparable to wire for cerclage fixation? A biomechanical analysis","volume":"11","author":"Westberg","year":"2019","journal-title":"Shoulder Elbow"},{"issue":"1","key":"10.1016\/j.injury.2021.03.040_bib0019","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/s00264-012-1702-7","article-title":"Biomechanical performance of different cable and wire cerclage configurations","volume":"37","author":"Lenz","year":"2013","journal-title":"Int Orthop"},{"issue":"3","key":"10.1016\/j.injury.2021.03.040_bib0020","doi-asserted-by":"crossref","first-page":"208","DOI":"10.55095\/achot2011\/033","article-title":"Cerclage handling for improved fracture treatment. A biomechanical study on the twisting procedure","volume":"78","author":"W\u00e4hnert","year":"2011","journal-title":"Acta Chir Orthop Traumatol Cech"},{"issue":"5","key":"10.1016\/j.injury.2021.03.040_bib0021","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1097\/00005131-199410000-00009","article-title":"Fatigue testing of cerclage stainless steel wire fixation","volume":"8","author":"Bostrom","year":"1994","journal-title":"J Orthop Trauma"},{"issue":"1","key":"10.1016\/j.injury.2021.03.040_bib0022","doi-asserted-by":"crossref","first-page":"e86035","DOI":"10.1371\/journal.pone.0086035","article-title":"Standardized loads acting in knee implants","volume":"9","author":"Bergmann","year":"2014","journal-title":"PLoS One"},{"issue":"1","key":"10.1016\/j.injury.2021.03.040_bib0023","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1007\/s00113-016-0281-2","article-title":"Mechanobiology of fracture healing part 2: relevance for internal fixation of fractures","volume":"120","author":"Claes","year":"2017","journal-title":"Unfallchirurg"},{"issue":"5","key":"10.1016\/j.injury.2021.03.040_bib0024","doi-asserted-by":"crossref","first-page":"894","DOI":"10.1053\/j.jfas.2018.03.025","article-title":"Foot loading and gait analysis evaluation of nonarticular tibial pilon fracture: a comparison of three surgical techniques","volume":"57","author":"Falzarano","year":"2018","journal-title":"J Foot Ankle Surg"},{"issue":"6","key":"10.1016\/j.injury.2021.03.040_bib0025","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1016\/S0736-0266(03)00098-6","article-title":"Shear movement at the fracture site delays healing in a diaphyseal fracture model","volume":"21","author":"Augat","year":"2003","journal-title":"J Orthop Res"},{"issue":"8","key":"10.1016\/j.injury.2021.03.040_bib0026","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0202702","article-title":"The mode of interfragmentary movement affects bone formation and revascularization after callus distraction","volume":"13","author":"Claes","year":"2018","journal-title":"PLoS One"},{"issue":"10","key":"10.1016\/j.injury.2021.03.040_bib0027","doi-asserted-by":"crossref","first-page":"1467","DOI":"10.1007\/s00402-012-1572-x","article-title":"Underneath the cerclage: an ex vivo study on the cerclage-bone interface mechanics","volume":"132","author":"Lenz","year":"2012","journal-title":"Arch Orthop Trauma Surg"},{"issue":"3","key":"10.1016\/j.injury.2021.03.040_bib0028","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1016\/j.jseint.2020.03.002","article-title":"Suture cerclage for stabilizing the humeral shaft during shoulder arthroplasty","volume":"4","author":"Eyberg","year":"2020","journal-title":"JSES Int"},{"issue":"10","key":"10.1016\/j.injury.2021.03.040_bib0029","doi-asserted-by":"crossref","first-page":"1568","DOI":"10.1016\/j.jse.2014.02.012","article-title":"Stainless steel wire versus FiberWire suture cerclage fixation to stabilize the humerus in total shoulder arthroplasty","volume":"23","author":"Renner","year":"2014","journal-title":"J Shoulder Elbow Surg"},{"issue":"10","key":"10.1016\/j.injury.2021.03.040_bib0030","doi-asserted-by":"crossref","DOI":"10.3390\/jcm9103068","article-title":"Good to excellent functional short-term outcome and low revision rates following primary anterior cruciate ligament repair using suture augmentation","volume":"9","author":"Schneider","year":"2020","journal-title":"J Clin Med"},{"issue":"6","key":"10.1016\/j.injury.2021.03.040_bib0031","doi-asserted-by":"crossref","first-page":"389","DOI":"10.55095\/achot2015\/065","article-title":"Fracture fixation using cerclage, research applied to surgery","volume":"82","author":"Perren","year":"2015","journal-title":"Acta Chir Orthop Traumatol Cech"},{"issue":"3","key":"10.1016\/j.injury.2021.03.040_bib0032","doi-asserted-by":"crossref","first-page":"190","DOI":"10.55095\/achot2011\/031","article-title":"evolution and potential of a Cinderella technology. An overview with reference to periprosthetic fractures","volume":"78","author":"Perren","year":"2011","journal-title":"Acta Chir Orthop Traumatol Cech"},{"issue":"2","key":"10.1016\/j.injury.2021.03.040_bib0033","doi-asserted-by":"crossref","first-page":"86","DOI":"10.5435\/00124635-201202000-00004","article-title":"Biomechanical testing of fracture fixation constructs: variability, validity, and clinical applicability","volume":"20","author":"Gardner","year":"2012","journal-title":"J Am Acad Orthop Surg"}],"container-title":["Injury"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138321002588?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138321002588?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,17]],"date-time":"2025-09-17T06:38:56Z","timestamp":1758091136000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0020138321002588"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8]]},"references-count":33,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2021,8]]}},"alternative-id":["S0020138321002588"],"URL":"https:\/\/doi.org\/10.1016\/j.injury.2021.03.040","relation":{},"ISSN":["0020-1383"],"issn-type":[{"value":"0020-1383","type":"print"}],"subject":[],"published":{"date-parts":[[2021,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biomechanical comparison of different cerclage types in addition to an angle stable plate osteosynthesis of distal tibial fractures","name":"articletitle","label":"Article Title"},{"value":"Injury","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.injury.2021.03.040","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}]}}