{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,16]],"date-time":"2025-12-16T12:41:45Z","timestamp":1765888905685,"version":"3.44.0"},"reference-count":33,"publisher":"Elsevier BV","issue":"7","license":[{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,5,20]],"date-time":"2022-05-20T00:00:00Z","timestamp":1653004800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004156","name":"Mahidol University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004156","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","injuryjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Injury"],"published-print":{"date-parts":[[2022,7]]},"DOI":"10.1016\/j.injury.2022.05.034","type":"journal-article","created":{"date-parts":[[2022,5,20]],"date-time":"2022-05-20T23:46:13Z","timestamp":1653090373000},"page":"2454-2461","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"title":["Effectiveness of prophylactic double-looped wiring in cementless Hip arthroplasty: A biomechanical study in osteoporotic bone model using impaction simulation system"],"prefix":"10.1016","volume":"53","author":[{"given":"Siwadol","family":"Wongsak","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1936-4456","authenticated-orcid":false,"given":"Paphon","family":"Sa-ngasoongsong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siwadol","family":"Pinitkwamdee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nutchanat","family":"Thongchuea","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abigyat Babu","family":"Prasai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eakkachai","family":"Warinsiriruk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chavarat","family":"Jarungvittayakon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4838-3245","authenticated-orcid":false,"given":"Suphaneewan","family":"Jaovisidha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pongsthorn","family":"Chanplakorn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"9","key":"10.1016\/j.injury.2022.05.034_bib0001","doi-asserted-by":"crossref","first-page":"1673","DOI":"10.1007\/s00264-015-2721-y","article-title":"Incidence and predisposing factors of periprosthetic proximal femoral fractures: a literature review","volume":"39","author":"Sidler-Maier","year":"2015","journal-title":"Int Orthop"},{"issue":"3","key":"10.1016\/j.injury.2022.05.034_bib0002","doi-asserted-by":"crossref","first-page":"330","DOI":"10.5301\/hip.2011.8408","article-title":"Hammering force during cementless total hip arthroplasty and risk of microfracture","volume":"21","author":"Sakai","year":"2011","journal-title":"Hip Int"},{"issue":"1","key":"10.1016\/j.injury.2022.05.034_bib0003","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/S0883-5403(99)90209-7","article-title":"Cerclage wiring technique after proximal femoral fracture in total hip arthroplasty","volume":"14","author":"Fishkin","year":"1999","journal-title":"J Arthroplasty"},{"issue":"2","key":"10.1016\/j.injury.2022.05.034_bib0004","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1177\/230949901502300222","article-title":"Intra-operative fractures in cementless bipolar hemiarthroplasty","volume":"23","author":"Kuo","year":"2015","journal-title":"J Orthop Surg (Hong Kong)"},{"issue":"3","key":"10.1016\/j.injury.2022.05.034_bib0005","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1080\/17453670710015210","article-title":"Inferior outcome after intraoperative femoral fracture in total hip arthroplasty: outcome in 519 patients from the Danish Hip Arthroplasty Registry","volume":"79","author":"Thillemann","year":"2008","journal-title":"Acta Orthop"},{"issue":"2","key":"10.1016\/j.injury.2022.05.034_bib0006","doi-asserted-by":"crossref","first-page":"113","DOI":"10.3109\/17453674.2015.1112712","article-title":"Risk factors for intraoperative calcar fracture in cementless total hip arthroplasty","volume":"87","author":"Miettinen","year":"2016","journal-title":"Acta Orthop"},{"issue":"4","key":"10.1016\/j.injury.2022.05.034_bib0007","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1302\/0301-620X.98B4.37201","article-title":"Epidemiology of periprosthetic fracture of the femur in 32 644 primary total hip arthroplasties: a 40-year experience","volume":"98-B","author":"Abdel","year":"2016","journal-title":"Bone Joint J"},{"issue":"9","key":"10.1016\/j.injury.2022.05.034_bib0008","doi-asserted-by":"crossref","first-page":"2000","DOI":"10.2106\/JBJS.H.00331","article-title":"Intraoperative periprosthetic fractures during total hip arthroplasty. Evaluation and management","volume":"90","author":"Davidson","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.injury.2022.05.034_bib0009","first-page":"59","article-title":"Risk factors for intraoperative periprosthetic femoral fractures during the total hip arthroplasty","volume":"77","author":"Nowak","year":"2012","journal-title":"Pol Orthop Traumatol"},{"issue":"1","key":"10.1016\/j.injury.2022.05.034_bib0010","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1186\/s13018-019-1494-1","article-title":"Risk analysis and clinical outcomes of intraoperative periprosthetic fractures: a retrospective study of 481 bipolar hemiarthroplasties","volume":"14","author":"Bellova","year":"2019","journal-title":"J Orthop Surg Res"},{"issue":"11","key":"10.1016\/j.injury.2022.05.034_bib0011","doi-asserted-by":"crossref","first-page":"3457","DOI":"10.1016\/j.arth.2017.06.018","article-title":"Reduced Incidence of intraoperative femur fracture with a second-generation tapered wedge stem","volume":"32","author":"Fleischman","year":"2017","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.injury.2022.05.034_bib0012","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1302\/0301-620X.99B1.BJJ-2016-0220.R1","article-title":"Periprosthetic femoral fractures and trying to avoid them: what is the contribution of femoral component design to the increased risk of periprosthetic femoral fracture?","author":"Carli","year":"2017","journal-title":"Bone Joint J"},{"issue":"10","key":"10.1016\/j.injury.2022.05.034_bib0013","doi-asserted-by":"crossref","first-page":"2194","DOI":"10.1097\/CORR.0000000000001932","article-title":"Cementless fixation is associated with increased risk of early and all-time revision after hemiarthroplasty but not after THA for femoral neck fracture: results from the American joint replacement registry","volume":"479","author":"Huddleston","year":"2021","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"10.1016\/j.injury.2022.05.034_bib0014","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1097\/CORR.0000000000000826","article-title":"Cemented or uncemented hemiarthroplasty for femoral neck fracture? Data from the Norwegian Hip fracture register","volume":"478","author":"Kristensen","year":"2020","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"10.1016\/j.injury.2022.05.034_bib0015","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.arth.2021.09.020","article-title":"Cause-Specific Stem Revision Risk in Primary Total Hip Arthroplasty Using Cemented vs Cementless Femoral Stem Fixation in a US Cohort","volume":"37","author":"Kelly","year":"2022","journal-title":"J Arthroplasty"},{"issue":"11","key":"10.1016\/j.injury.2022.05.034_bib0016","doi-asserted-by":"crossref","first-page":"3667","DOI":"10.1016\/j.arth.2021.06.029","article-title":"Cemented Vs cementless femoral fixation for total Hip arthroplasty after displaced femoral neck fracture: a Nationwide analysis of short-term complications and readmission rates","volume":"36","author":"Heckmann","year":"2021","journal-title":"J Arthroplasty"},{"issue":"3","key":"10.1016\/j.injury.2022.05.034_bib0017","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1080\/17453674.2020.1745420","article-title":"Lundbeck Foundation Center for Fast-track H, et\u00a0al. Postoperative 30-day complications after cemented\/hybrid versus cementless total hip arthroplasty in osteoarthritis patients >70 years","volume":"91","author":"Lindberg-Larsen","year":"2020","journal-title":"Acta Orthop"},{"issue":"3","key":"10.1016\/j.injury.2022.05.034_bib0018","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1080\/17453674.2020.1745510","article-title":"The role of bone cement for the development of intraoperative hypotension and hypoxia and its impact on mortality in hemiarthroplasty for femoral neck fractures","volume":"91","author":"Olsen","year":"2020","journal-title":"Acta Orthop"},{"issue":"2","key":"10.1016\/j.injury.2022.05.034_bib0019","doi-asserted-by":"crossref","first-page":"143","DOI":"10.3928\/0147-7447-19920201-06","article-title":"Prophylactic cerclage: a method of preventing femur fracture in uncemented total hip arthroplasty","volume":"15","author":"Herzwurm","year":"1992","journal-title":"Orthopedics"},{"issue":"6","key":"10.1016\/j.injury.2022.05.034_bib0020","doi-asserted-by":"crossref","first-page":"e1183","DOI":"10.3928\/01477447-20160808-03","article-title":"Prophylactic cerclage with braided Polyblend suture during femoral broaching","volume":"39","author":"Nwankwo","year":"2016","journal-title":"Orthopedics"},{"issue":"6","key":"10.1016\/j.injury.2022.05.034_bib0021","doi-asserted-by":"crossref","first-page":"2023","DOI":"10.1016\/j.arth.2017.01.019","article-title":"The effect of prophylactic cerclage wires in primary total Hip arthroplasty: a biomechanical study","volume":"32","author":"ACt","year":"2017","journal-title":"J Arthroplasty"},{"issue":"1","key":"10.1016\/j.injury.2022.05.034_bib0022","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1007\/BF00453214","article-title":"Measuring stability of wire cerclage in femoral fractures when performing total hip replacement. In vitro study on a standardized bone model","volume":"115","author":"Wagner","year":"1996","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.injury.2022.05.034_bib0023","doi-asserted-by":"crossref","DOI":"10.1016\/j.jbiomech.2020.110018","article-title":"Evaluating the mechanical response of novel synthetic femurs for representing osteoporotic bone","volume":"111","author":"Gluek","year":"2020","journal-title":"J Biomech"},{"key":"10.1016\/j.injury.2022.05.034_bib0024","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.medengphy.2019.12.004","article-title":"Quantitative characterisation of impaction events during femoral broaching in total hip arthroplasty","volume":"76","author":"Preutenborbeck","year":"2020","journal-title":"Med Eng Phys"},{"issue":"8","key":"10.1016\/j.injury.2022.05.034_bib0025","doi-asserted-by":"crossref","first-page":"1449","DOI":"10.1016\/j.arth.2015.02.026","article-title":"Intraoperative periprosthetic femur fracture: a biomechanical analysis of cerclage fixation","volume":"30","author":"Frisch","year":"2015","journal-title":"J Arthroplasty"},{"issue":"1","key":"10.1016\/j.injury.2022.05.034_bib0026","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/s00264-012-1702-7","article-title":"Biomechanical performance of different cable and wire cerclage configurations","volume":"37","author":"Lenz","year":"2013","journal-title":"Int Orthop"},{"issue":"7","key":"10.1016\/j.injury.2022.05.034_bib0027","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1016\/S0883-5403(97)90007-3","article-title":"Comparison of cerclage techniques using a hose clamp versus monofilament cerclage wire or cable","volume":"12","author":"Liu","year":"1997","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.injury.2022.05.034_bib0028","article-title":"Bone cement implantation syndrome in cemented hip hemiarthroplasty-a persistent risk","author":"Weingartner","year":"2021","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"5","key":"10.1016\/j.injury.2022.05.034_bib0029","doi-asserted-by":"crossref","first-page":"800","DOI":"10.1093\/bja\/aeu226","article-title":"Bone cement implantation syndrome in cemented hemiarthroplasty for femoral neck fracture: incidence, risk factors, and effect on outcome","volume":"113","author":"Olsen","year":"2014","journal-title":"Br J Anaesth"},{"issue":"7S","key":"10.1016\/j.injury.2022.05.034_bib0030","doi-asserted-by":"crossref","first-page":"S363","DOI":"10.1016\/j.arth.2021.02.012","article-title":"Periprosthetic femur fracture risk: influenced by stem choice, not surgical approach","volume":"36","author":"Sershon","year":"2021","journal-title":"J Arthroplasty"},{"issue":"1","key":"10.1016\/j.injury.2022.05.034_bib0031","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1186\/s13018-021-02457-8","article-title":"Long-term outcomes of cementless femoral stem revision with the Wagner cone prosthesis","volume":"16","author":"Park","year":"2021","journal-title":"J Orthop Surg Res"},{"issue":"6","key":"10.1016\/j.injury.2022.05.034_bib0032","doi-asserted-by":"crossref","first-page":"2017","DOI":"10.1016\/j.arth.2016.12.031","article-title":"Broach handle design changes force distribution in the femur during total Hip arthroplasty","volume":"32","author":"Greenhill","year":"2017","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.injury.2022.05.034_bib0033","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1016\/j.ijmecsci.2018.05.051","article-title":"Vibro-acoustic and nonlinear analysis of cadavric femoral bone impaction in cavity preparations","volume":"144","author":"Oberst","year":"2018","journal-title":"Int J Mech Sci"}],"container-title":["Injury"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002013832200362X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002013832200362X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,17]],"date-time":"2025-09-17T06:41:32Z","timestamp":1758091292000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S002013832200362X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7]]},"references-count":33,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2022,7]]}},"alternative-id":["S002013832200362X"],"URL":"https:\/\/doi.org\/10.1016\/j.injury.2022.05.034","relation":{},"ISSN":["0020-1383"],"issn-type":[{"type":"print","value":"0020-1383"}],"subject":[],"published":{"date-parts":[[2022,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effectiveness of prophylactic double-looped wiring in cementless Hip arthroplasty: A biomechanical study in osteoporotic bone model using impaction simulation system","name":"articletitle","label":"Article Title"},{"value":"Injury","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.injury.2022.05.034","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 The Author(s). Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}]}}