{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,18]],"date-time":"2025-09-18T10:29:32Z","timestamp":1758191372442,"version":"3.44.0"},"reference-count":37,"publisher":"Elsevier BV","issue":"11","license":[{"start":{"date-parts":[[2022,11,1]],"date-time":"2022-11-01T00:00:00Z","timestamp":1667260800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,11,1]],"date-time":"2022-11-01T00:00:00Z","timestamp":1667260800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,8,25]],"date-time":"2022-08-25T00:00:00Z","timestamp":1661385600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","injuryjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Injury"],"published-print":{"date-parts":[[2022,11]]},"DOI":"10.1016\/j.injury.2022.08.041","type":"journal-article","created":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T22:45:26Z","timestamp":1660776326000},"page":"3748-3753","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Anterior cervical plating combined with zero-profile anchored spacer for the treatment of cervical facet dislocation in elderly patients"],"prefix":"10.1016","volume":"53","author":[{"given":"Chunxiao","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaowen","family":"Du","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hongkai","family":"Song","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaojie","family":"Tang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiangwei","family":"Tan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qinyong","family":"Song","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haifei","family":"Cao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Xiong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.injury.2022.08.041_bib0001","doi-asserted-by":"crossref","first-page":"S501","DOI":"10.1097\/00007632-199110001-00009","article-title":"Failure of halo vest to prevent in vivo motion in patients with injured cervical spines","volume":"16","author":"Anderson","year":"1991","journal-title":"Spine (Phila Pa 1976)"},{"issue":"6","key":"10.1016\/j.injury.2022.08.041_bib0002","doi-asserted-by":"crossref","first-page":"S187","DOI":"10.1097\/00007632-199106001-00002","article-title":"Intervertebral disc injury complicating cervical spine trauma","volume":"16","author":"Rizzolo","year":"1991","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"10.1016\/j.injury.2022.08.041_bib0003","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1097\/00013611-199400910-00003","article-title":"Cervical disk herniation in association with traumatic facet dislocation[J]","volume":"9","author":"Tribus","year":"1994","journal-title":"Techn Orthopaed"},{"issue":"6","key":"10.1016\/j.injury.2022.08.041_bib0004","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1097\/01.brs.0000202811.03476.a0","article-title":"Anterior reduction for cervical spine dislocation","volume":"31","author":"Reindl","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"10.1016\/j.injury.2022.08.041_bib0005","doi-asserted-by":"crossref","first-page":"35","DOI":"10.3171\/2014.11.SPINE14805","article-title":"A single-stage posterior approach with open reduction and pedicle screw fixation in subaxial cervical facet dislocations","volume":"23","author":"Park","year":"2015","journal-title":"J Neurosurg Spine"},{"issue":"25","key":"10.1016\/j.injury.2022.08.041_bib0006","doi-asserted-by":"crossref","first-page":"2082","DOI":"10.1097\/BRS.0b013e31825ee846","article-title":"Anterior decompression and nonstructural bone grafting and posterior fixation for cervical facet dislocation with traumatic disc herniation","volume":"37","author":"Feng","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"10.1016\/j.injury.2022.08.041_bib0007","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1007\/s00586-010-1589-1","article-title":"Posterior approach for cervical fracture-dislocations with traumatic disc herniation","volume":"20","author":"Nakashima","year":"2011","journal-title":"Eur Spine J"},{"issue":"1","key":"10.1016\/j.injury.2022.08.041_bib0008","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1177\/0954411919888110","article-title":"Traction load, tong position, and head support significantly influence cervical spine loading during traction","volume":"234","author":"Hammond","year":"2020","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1016\/j.injury.2022.08.041_bib0009","doi-asserted-by":"crossref","first-page":"e362","DOI":"10.1016\/j.wneu.2019.04.153","article-title":"A novel anterior-only surgical approach for reduction and fixation of cervical facet dislocation","volume":"128","author":"Liu","year":"2019","journal-title":"World Neurosurg"},{"issue":"10","key":"10.1016\/j.injury.2022.08.041_bib0010","doi-asserted-by":"crossref","first-page":"2380","DOI":"10.1007\/s00586-019-06073-3","article-title":"Comparison of a novel anterior-only approach and the conventional posterior-anterior approach for cervical facet dislocation: a retrospective study","volume":"28","author":"Liu","year":"2019","journal-title":"Eur Spine J"},{"issue":"1","key":"10.1016\/j.injury.2022.08.041_bib0011","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1097\/00007632-200101010-00005","article-title":"A biomechanical comparison of modern anterior and posterior plate fixation of the cervical spine","volume":"26","author":"Do Koh","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"issue":"5","key":"10.1016\/j.injury.2022.08.041_bib0012","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1016\/j.jocn.2012.03.045","article-title":"Distractive flexion injuries of the subaxial cervical spine treated with a posterior procedure using cervical pedicle screws or a combined anterior and posterior procedure","volume":"20","author":"Tofuku","year":"2013","journal-title":"J Clin Neurosci"},{"issue":"1","key":"10.1016\/j.injury.2022.08.041_bib0013","first-page":"18","article-title":"Cervical facet dislocation: techniques for ventral reduction and stabilization","volume":"92","author":"Ordonez","year":"2000","journal-title":"J Neurosurg"},{"issue":"17","key":"10.1016\/j.injury.2022.08.041_bib0014","doi-asserted-by":"crossref","first-page":"1858","DOI":"10.1097\/00007632-200209010-00010","article-title":"Unilateral cervical facet dislocation: injury mechanism and biomechanical consequences","volume":"27","author":"Crawford","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"issue":"10","key":"10.1016\/j.injury.2022.08.041_bib0015","doi-asserted-by":"crossref","first-page":"1122","DOI":"10.1097\/00007632-198910000-00016","article-title":"Biomechanical evaluation of cervical spinal stabilization methods in a human cadaveric model","volume":"14","author":"Coe","year":"1989","journal-title":"Spine (Phila Pa 1976)"},{"issue":"7","key":"10.1016\/j.injury.2022.08.041_bib0016","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1097\/00007632-198807000-00015","article-title":"A biomechanical evaluation of cervical spinal stabilization methods in a bovine model. Static and cyclical loading","volume":"13","author":"Sutterlin","year":"1988","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"10.1016\/j.injury.2022.08.041_bib0017","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1097\/00007632-200101010-00005","article-title":"A biomechanical comparison of modern anterior and posterior plate fixation of the cervical spine","volume":"26","author":"Do Koh","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"issue":"6","key":"10.1016\/j.injury.2022.08.041_bib0018","doi-asserted-by":"crossref","first-page":"1374","DOI":"10.1016\/j.wneu.2014.02.008","article-title":"Traumatic high-grade cervical dislocation: treatment strategies and outcomes","volume":"82","author":"Sribnick","year":"2014","journal-title":"World Neurosurg"},{"issue":"2","key":"10.1016\/j.injury.2022.08.041_bib0019","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1093\/neuros\/nyy032","article-title":"Anterior reduction and fusion of cervical facet dislocations","volume":"84","author":"Theodotou","year":"2019","journal-title":"Neurosurgery"},{"issue":"6","key":"10.1016\/j.injury.2022.08.041_bib0020","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1227\/00006123-198912000-00003","article-title":"Anterior cervical fusion and osteosynthetic stabilization according to Caspar: a prospective study of 41 patients with fractures and\/or dislocations of the cervical spine","volume":"25","author":"Goffin","year":"1989","journal-title":"Neurosurgery"},{"issue":"1","key":"10.1016\/j.injury.2022.08.041_bib0021","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1097\/BRS.0000000000000046","article-title":"Management of subaxial cervical facet dislocation through anterior approach monitored by spinal cord evoked potential","volume":"39","author":"Du","year":"2014","journal-title":". Spine (Phila Pa 1976)"},{"issue":"4","key":"10.1016\/j.injury.2022.08.041_bib0022","first-page":"397","article-title":"Fractures and dislocations of the lower cervical spine: surgical treatment. A review of 83 cases","volume":"88","author":"De Iure","year":"2003","journal-title":"Chir Organi Mov"},{"issue":"6","key":"10.1016\/j.injury.2022.08.041_bib0023","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1007\/s00701-008-1574-1","article-title":"Anterior pedicle screw fixation for multilevel cervical corpectomy and spinal fusion","volume":"150","author":"Aramomi","year":"2008","journal-title":"Acta Neurochir (Wien)"},{"issue":"8","key":"10.1016\/j.injury.2022.08.041_bib0024","doi-asserted-by":"crossref","first-page":"1801","DOI":"10.1016\/j.injury.2017.07.006","article-title":"Anterior pedicle spreader reduction for unilateral cervical facet dislocation","volume":"48","author":"Zhang","year":"2017","journal-title":"Injury"},{"issue":"22","key":"10.1016\/j.injury.2022.08.041_bib0025","doi-asserted-by":"crossref","first-page":"2529","DOI":"10.1097\/00007632-199411001-00007","article-title":"Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine","volume":"19","author":"Kotani","year":"1994","journal-title":"Spine (Phila Pa 1976)"},{"issue":"5","key":"10.1016\/j.injury.2022.08.041_bib0026","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1097\/01.bsd.0000177211.44960.71","article-title":"Influence of anterior cervical plate design on Dysphagia: a 2-year prospective longitudinal follow-up study","volume":"18","author":"Lee","year":"2005","journal-title":"J Spinal Disord Tech"},{"issue":"22","key":"10.1016\/j.injury.2022.08.041_bib0027","doi-asserted-by":"crossref","first-page":"2453","DOI":"10.1097\/00007632-200211150-00007","article-title":"Incidence of dysphagia after anterior cervical spine surgery: a prospective study","volume":"27","author":"Bazaz","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"10.1016\/j.injury.2022.08.041_bib0028","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1007\/s11999-010-1597-9","article-title":"A new zero-profile implant for stand-alone anterior cervical interbody fusion","volume":"469","author":"Scholz","year":"2011","journal-title":"Clin Orthop Relat Res"},{"issue":"6","key":"10.1016\/j.injury.2022.08.041_bib0029","doi-asserted-by":"crossref","first-page":"S868","DOI":"10.1007\/s00586-013-3005-0","article-title":"Zero-P: a new zero-profile cage-plate device for single and multilevel ACDF. A single institution series with four years maximum follow-up and review of the literature on zero-profile devices","volume":"22","author":"Barbagallo","year":"2013","journal-title":"Eur Spine J"},{"issue":"2","key":"10.1016\/j.injury.2022.08.041_bib0030","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/BRS.0b013e31818ff9c4","article-title":"A new stand-alone cervical anterior interbody fusion device: biomechanical comparison with established anterior cervical fixation devices","volume":"34","author":"Scholz","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"issue":"6","key":"10.1016\/j.injury.2022.08.041_bib0031","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1016\/j.clinbiomech.2011.12.013","article-title":"A comparative biomechanical study of a novel integrated plate spacer for stabilization of cervical spine: an in vitro human cadaveric model","volume":"27","author":"Majid","year":"2012","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"1","key":"10.1016\/j.injury.2022.08.041_bib0032","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.spinee.2013.06.088","article-title":"Biomechanics of an integrated interbody device versus ACDF anterior locking plate in a single-level cervical spine fusion construct","volume":"14","author":"Stein","year":"2014","journal-title":"Spine J"},{"issue":"2","key":"10.1016\/j.injury.2022.08.041_bib0033","doi-asserted-by":"crossref","first-page":"202","DOI":"10.3340\/jkns.2019.0139","article-title":"Anterior approach following intraoperative reduction for cervical facet fracture and dislocation","volume":"63","author":"Kim","year":"2020","journal-title":"J Korean Neurosurg Soc"},{"key":"10.1016\/j.injury.2022.08.041_bib0034","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.12659\/MSM.908515","article-title":"Management of severe lower cervical facet dislocation without vertebral body fracture using skull traction and an anterior approach","volume":"24","author":"Miao","year":"2018","journal-title":"Med Sci Monit"},{"issue":"9","key":"10.1016\/j.injury.2022.08.041_bib0035","doi-asserted-by":"crossref","first-page":"1580","DOI":"10.1016\/j.spinee.2021.04.010","article-title":"Pullout strength of pedicle screws using cadaveric vertebrae with or without artificial demineralization","volume":"21","author":"Lee","year":"2021","journal-title":"Spine J"},{"issue":"11","key":"10.1016\/j.injury.2022.08.041_bib0036","doi-asserted-by":"crossref","first-page":"2891","DOI":"10.1007\/s00586-017-5091-x","article-title":"Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength","volume":"26","author":"Weiser","year":"2017","journal-title":"Eur Spine J"},{"issue":"10","key":"10.1016\/j.injury.2022.08.041_bib0037","first-page":"1174","article-title":"Biomechanical study on effect of polymethylmethacrylate augmentation on cervical stability after anterior cervical interbody fusion","volume":"24","author":"Chen","year":"2010","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"}],"container-title":["Injury"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002013832200599X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002013832200599X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,17]],"date-time":"2025-09-17T06:46:48Z","timestamp":1758091608000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S002013832200599X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11]]},"references-count":37,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2022,11]]}},"alternative-id":["S002013832200599X"],"URL":"https:\/\/doi.org\/10.1016\/j.injury.2022.08.041","relation":{},"ISSN":["0020-1383"],"issn-type":[{"type":"print","value":"0020-1383"}],"subject":[],"published":{"date-parts":[[2022,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Anterior cervical plating combined with zero-profile anchored spacer for the treatment of cervical facet dislocation in elderly patients","name":"articletitle","label":"Article Title"},{"value":"Injury","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.injury.2022.08.041","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}]}}