{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T13:44:29Z","timestamp":1777643069372,"version":"3.51.4"},"reference-count":34,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100005322","name":"Recep Tayyip Erdo\u011fan University","doi-asserted-by":"publisher","award":["TDH-2018-986"],"award-info":[{"award-number":["TDH-2018-986"]}],"id":[{"id":"10.13039\/501100005322","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","injuryjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Injury"],"published-print":{"date-parts":[[2024,12]]},"DOI":"10.1016\/j.injury.2024.111983","type":"journal-article","created":{"date-parts":[[2024,10,28]],"date-time":"2024-10-28T13:07:57Z","timestamp":1730120877000},"page":"111983","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Biomechanical effects of different miniplate use on bone and miniplate systems in multiple mandible fracture: A finite element study"],"prefix":"10.1016","volume":"55","author":[{"given":"Erdin\u00e7","family":"Sulukan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5910-2218","authenticated-orcid":false,"given":"Zeynep","family":"G\u00fcmr\u00fck\u00e7\u00fc","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"3","key":"10.1016\/j.injury.2024.111983_bib0001","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.ajoms.2017.12.001","article-title":"A detailed analysis of mandibular fractures epidemiology, treatment and outcomes: a 5-year retrospective study","volume":"30","author":"Abotaleb","year":"2018","journal-title":"J Oral Maxillofac Surg Med Pathol"},{"issue":"10","key":"10.1016\/j.injury.2024.111983_bib0002","doi-asserted-by":"crossref","first-page":"1596","DOI":"10.29309\/TPMJ\/18.4574","article-title":"Mandibular fractures; pattern and presentation of mandibular fractures in Dow International Dental College: five year review","volume":"25","author":"Ahmed","year":"2018","journal-title":"Professional Med J"},{"key":"10.1016\/j.injury.2024.111983_bib0003","series-title":"An introduction to oral and maxillofacial surgery","author":"Mitchell","year":"2014"},{"issue":"8","key":"10.1016\/j.injury.2024.111983_bib0004","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1111\/joor.13178","article-title":"Functional appliance treatment for mandibular fractures: a systematic review with meta-analyses","volume":"48","author":"Stahli","year":"2021","journal-title":"J Oral Rehabil"},{"issue":"2","key":"10.1016\/j.injury.2024.111983_bib0005","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.bjoms.2004.10.007","article-title":"Three-dimensional finite element analysis used to compare methods of fixation after sagittal split ramus osteotomy: setback surgery-posterior loading","volume":"43","author":"Erkmen","year":"2005","journal-title":"Br J Oral Maxillofac Surg"},{"issue":"1","key":"10.1016\/j.injury.2024.111983_bib0006","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.jobcr.2015.11.001","article-title":"Management of mandibular angle fractures using a 1.7 mm 3-dimensional strut plate","volume":"6","author":"Pandey","year":"2016","journal-title":"J Oral Biol Craniofac Res"},{"issue":"7","key":"10.1016\/j.injury.2024.111983_bib0007","doi-asserted-by":"crossref","first-page":"1464","DOI":"10.1016\/j.joms.2017.02.028","article-title":"Biomechanical evaluation of different plating methods used in mandibular angle fractures with 3-dimensional finite element analysis: favorable fractures","volume":"75","author":"Ayali","year":"2017","journal-title":"J Oral Maxillofac Surg"},{"issue":"6","key":"10.1016\/j.injury.2024.111983_bib0008","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1016\/j.joms.2005.11.092","article-title":"Comparative evaluation of different miniplates for internal fixation of mandible fractures using finite element analysis","volume":"66","author":"Arbag","year":"2008","journal-title":"J Oral Maxillofac Surg"},{"issue":"5","key":"10.1016\/j.injury.2024.111983_bib0009","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1016\/j.joms.2013.11.026","article-title":"An algorithm for the treatment of noncondylar mandibular fractures","volume":"72","author":"Ellis","year":"2014","journal-title":"J Oral Maxillofac Surg"},{"issue":"1","key":"10.1016\/j.injury.2024.111983_bib0010","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1054\/ijom.2000.0182","article-title":"Combination of microplate and miniplate for osteosynthesis of mandibular fractures: an experimental study","volume":"31","author":"Feller","year":"2002","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"3","key":"10.1016\/j.injury.2024.111983_bib0011","doi-asserted-by":"crossref","DOI":"10.1016\/j.tripleo.2009.11.003","article-title":"A biomechanical analysis of titanium miniplates used for treatment of mandibular symphyseal fractures with the finite element method","volume":"109","author":"Ji","year":"2010","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"issue":"5","key":"10.1016\/j.injury.2024.111983_bib0012","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.ijom.2004.10.009","article-title":"Comparison of different fixation methods following sagittal split ramus osteotomies using three-dimensional finite elements analysis - Part 1: advancement surgery posterior loading","volume":"34","author":"Erkmen","year":"2005","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"3","key":"10.1016\/j.injury.2024.111983_bib0013","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1016\/j.ijom.2014.10.012","article-title":"Comparison between three-dimensional and standard miniplates in the management of mandibular angle fractures: a prospective, randomized, double-blind, controlled clinical study","volume":"44","author":"Al-Moraissi","year":"2015","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"6","key":"10.1016\/j.injury.2024.111983_bib0014","doi-asserted-by":"crossref","first-page":"e115","DOI":"10.11607\/jomi.7696","article-title":"Biomechanical evaluation of zygomatic implant use in patients with different buccal maxillary defect levels","volume":"34","author":"G\u00fcmr\u00fck\u00e7\u00fc","year":"2019","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"9","key":"10.1016\/j.injury.2024.111983_bib0015","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1016\/j.medengphy.2015.06.001","article-title":"Failure location prediction by finite element analysis for an additive manufactured mandible implant","volume":"37","author":"Huo","year":"2015","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.injury.2024.111983_bib0016","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.procir.2013.01.029","article-title":"Towards a rigorous approach to designing a temporomandibular joint prosthesis. From clinical challenge to numerical prototype","volume":"5","author":"Mesnard","year":"2013","journal-title":"Procedia CIRP"},{"issue":"Suppl 1","key":"10.1016\/j.injury.2024.111983_bib0017","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1080\/10255842.2013.815847","article-title":"Evaluation of a primary TMJ implant fixation using screws: a numerical study","volume":"16","author":"Duarte","year":"2013","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"3","key":"10.1016\/j.injury.2024.111983_bib0018","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/S0021-9290(02)00416-5","article-title":"A three-dimensional numerical simulation of mandible fracture reduction with screwed miniplates","volume":"36","author":"Fernandez","year":"2003","journal-title":"J Biomech"},{"issue":"10","key":"10.1016\/j.injury.2024.111983_bib0019","doi-asserted-by":"crossref","first-page":"2581","DOI":"10.1007\/s11517-023-02854-7","article-title":"Biomechanical influence of plate configurations on mandible subcondylar fracture fixation: a finite element study","volume":"61","author":"Gupta","year":"2023","journal-title":"Med Biol Eng Comput"},{"issue":"4","key":"10.1016\/j.injury.2024.111983_bib0020","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.ijom.2009.11.003","article-title":"Biomechanics of mandibular reconstruction: a review","volume":"39","author":"Wong","year":"2010","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"6","key":"10.1016\/j.injury.2024.111983_bib0021","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.tripleo.2006.12.016","article-title":"Evaluation of different miniplates in fixation of fractured human mandible with the finite element method","volume":"103","author":"Korkmaz","year":"2007","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"issue":"7","key":"10.1016\/j.injury.2024.111983_bib0022","doi-asserted-by":"crossref","first-page":"1527","DOI":"10.1016\/j.injury.2020.03.057","article-title":"A mechanical study of novel additive manufactured modular mandible fracture fixation plates-Preliminary Study with finite element analysis","volume":"51","author":"Palka","year":"2020","journal-title":"Injury"},{"issue":"6","key":"10.1016\/j.injury.2024.111983_bib0023","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/S0022-3913(07)60006-7","article-title":"Tilting of splinted implants for improved prosthodontic support: a two-dimensional finite element analysis","volume":"97","author":"Zampelis","year":"2007","journal-title":"J Prosthet Dent"},{"issue":"2","key":"10.1016\/j.injury.2024.111983_bib0024","first-page":"93","article-title":"Comparison of finite element and photoelastic stress analysis methods","volume":"15","author":"\u0130nan","year":"2009","journal-title":"T\u00fcrkiye Klinikleri Di\u015f Hekimli\u011fi Bilimleri Dergisi"},{"issue":"6","key":"10.1016\/j.injury.2024.111983_bib0025","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1016\/j.ajodo.2003.06.014","article-title":"Biomechanical evaluation of mandibular midline distraction osteogenesis by using the finite element method","volume":"125","author":"Basciftci","year":"2004","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"Suppl 1","key":"10.1016\/j.injury.2024.111983_bib0026","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1080\/10255842.2013.815975","article-title":"The importance of the geometry of the screws in TMJ implant fixation","volume":"16","author":"Ramos","year":"2013","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"5","key":"10.1016\/j.injury.2024.111983_bib0027","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.cjtee.2019.08.001","article-title":"Evaluation of labial versus labio-inferior lines of osteosynthesis using 3D miniplate for fractures of anterior mandible: a finite element analysis with a pilot clinical trial","volume":"22","author":"Ponvel","year":"2019","journal-title":"Chin J Traumatol"},{"issue":"2","key":"10.1016\/j.injury.2024.111983_bib0028","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1007\/s12663-016-0903-9","article-title":"Evaluating the effect of minimizing screws on stabilization of symphysis mandibular fracture by 3D finite element analysis","volume":"16","author":"Kharmanda","year":"2017","journal-title":"J Maxillofac Oral Surg"},{"issue":"10","key":"10.1016\/j.injury.2024.111983_bib0029","doi-asserted-by":"crossref","first-page":"1551","DOI":"10.1016\/j.jcms.2019.07.014","article-title":"Novel design of miniplate for fixation of fractures at transition zone of parasymphysis-body region of mandible\u2013A clinical randomised study","volume":"47","author":"Datarkar","year":"2019","journal-title":"J CranioMaxillofac Surg"},{"issue":"1","key":"10.1016\/j.injury.2024.111983_bib0030","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2302\/kjm.55.1","article-title":"A comparative study of most suitable miniplate fixation for mandibular symphysis fracture using a finite element model","volume":"55","author":"Kimura","year":"2006","journal-title":"Keio J Med"},{"issue":"7","key":"10.1016\/j.injury.2024.111983_bib0031","doi-asserted-by":"crossref","first-page":"1585","DOI":"10.1016\/j.joms.2009.07.084","article-title":"Three-dimensional finite element analysis of mechanical stress in symphyseal fractured human mandible reduced with miniplates during mastication","volume":"68","author":"Wang","year":"2010","journal-title":"J Oral Maxillofac Surg"},{"issue":"1","key":"10.1016\/j.injury.2024.111983_bib0032","first-page":"1","article-title":"A customized fixation plate with novel structure designed by topological optimization for mandibular angle fracture based on finite element analysis","volume":"16","author":"Y-f","year":"2017","journal-title":"Biomed Eng Online"},{"issue":"3","key":"10.1016\/j.injury.2024.111983_bib0033","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/j.bjps.2016.10.026","article-title":"Effect of interfragmentary gap on the mechanical behavior of mandibular angle fracture with three fixation designs: a finite element analysis","volume":"70","author":"Wang","year":"2017","journal-title":"J Plast Reconst Aesthet Surg"},{"key":"10.1016\/j.injury.2024.111983_bib0034","article-title":"The physical metallurgy of titanium alloys","volume":"3","author":"Collings","year":"1984","journal-title":"Metals Park Ohio"}],"container-title":["Injury"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138324007125?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0020138324007125?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T21:40:41Z","timestamp":1777412441000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0020138324007125"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12]]},"references-count":34,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["S0020138324007125"],"URL":"https:\/\/doi.org\/10.1016\/j.injury.2024.111983","relation":{},"ISSN":["0020-1383"],"issn-type":[{"value":"0020-1383","type":"print"}],"subject":[],"published":{"date-parts":[[2024,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biomechanical effects of different miniplate use on bone and miniplate systems in multiple mandible fracture: A finite element study","name":"articletitle","label":"Article Title"},{"value":"Injury","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.injury.2024.111983","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"111983"}}