{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T12:47:26Z","timestamp":1782132446950,"version":"3.54.5"},"reference-count":17,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T00:00:00Z","timestamp":1779753600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Interventional Pain Medicine"],"published-print":{"date-parts":[[2026,6]]},"DOI":"10.1016\/j.inpm.2026.100793","type":"journal-article","created":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T11:51:33Z","timestamp":1781265093000},"page":"100793","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Lumbar medial branch radiofrequency neurotomy in a patient with a leadless pacemaker: a case report"],"prefix":"10.1016","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9071-0257","authenticated-orcid":false,"given":"James","family":"Bruzzese","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7833-1753","authenticated-orcid":false,"given":"Lisa V.","family":"Doan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.inpm.2026.100793_bib1","doi-asserted-by":"crossref","first-page":"2859","DOI":"10.2147\/JPR.S323362","article-title":"Efficacy of radiofrequency neurotomy in chronic low back pain: a systematic review and meta-analysis","volume":"14","author":"Janapala","year":"2021","journal-title":"J Pain Res"},{"issue":"10070","key":"10.1016\/j.inpm.2026.100793_bib2","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1016\/S0140-6736(16)30970-9","article-title":"Non-specific low back pain","volume":"389","author":"Maher","year":"2017","journal-title":"Lancet"},{"issue":"25","key":"10.1016\/j.inpm.2026.100793_bib3","doi-asserted-by":"crossref","DOI":"10.1056\/NEJMvcm2211108","article-title":"Medial branch blocks and radiofrequency ablation for low back pain from facet joints","volume":"389","author":"Hao","year":"2023","journal-title":"N Engl J Med"},{"issue":"6","key":"10.1016\/j.inpm.2026.100793_bib4","doi-asserted-by":"crossref","first-page":"1122","DOI":"10.1093\/pm\/pnz349","article-title":"Systematic review of the effectiveness of lumbar medial branch thermal radiofrequency neurotomy, stratified for diagnostic methods and procedural technique","volume":"21","author":"Schneider","year":"2020","journal-title":"Pain Med"},{"issue":"1","key":"10.1016\/j.inpm.2026.100793_bib5","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.aan.2016.07.008","article-title":"The perioperative management of implantable pacemakers and cardioverter-defibrillators","volume":"34","author":"Schulman","year":"2016","journal-title":"Adv Anesth"},{"issue":"2","key":"10.1016\/j.inpm.2026.100793_bib6","doi-asserted-by":"crossref","DOI":"10.1097\/ALN.0000000000002990","article-title":"Sustained ventricular tachycardia secondary to R-on-T phenomenon caused by temporary ventricular epicardial pacemaker undersensing after cardiac surgery","volume":"132","author":"Chen","year":"2020","journal-title":"Anesthesiology"},{"issue":"1","key":"10.1016\/j.inpm.2026.100793_bib7","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1053\/j.jvca.2018.05.034","article-title":"Anesthetic management of a patient with a leadless pacemaker undergoing cardiac surgery","volume":"33","author":"Reddy","year":"2019","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"6","key":"10.1016\/j.inpm.2026.100793_bib8","doi-asserted-by":"crossref","first-page":"1594","DOI":"10.1053\/j.jvca.2016.06.021","article-title":"Perioperative management of a leadless pacemaker: the paucity of evidence-based guidelines","volume":"30","author":"Mickus","year":"2016","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"8","key":"10.1016\/j.inpm.2026.100793_bib9","doi-asserted-by":"crossref","first-page":"e183","DOI":"10.1161\/CIR.0000000000001264","article-title":"Periprocedural management and multidisciplinary care pathways for patients with cardiac implantable electronic devices: a scientific statement from the American heart association","volume":"150","author":"Wan","year":"2024","journal-title":"Circulation"},{"issue":"2","key":"10.1016\/j.inpm.2026.100793_bib10","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1093\/pm\/pny213","article-title":"Radiofrequency neurotomy for facet joint pain in patients with permanent pacemakers and defibrillators","volume":"20","author":"Smith","year":"2019","journal-title":"Pain Med"},{"issue":"2","key":"10.1016\/j.inpm.2026.100793_bib11","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1097\/ALN.0000000000002821","article-title":"Practice advisory for the perioperative management of patients with cardiac implantable electronic devices: pacemakers and implantable cardioverter\u2013defibrillators 2020","volume":"132","year":"2020","journal-title":"Anesthesiology"},{"key":"10.1016\/j.inpm.2026.100793_bib12","doi-asserted-by":"crossref","first-page":"3693","DOI":"10.2147\/JPR.S419594","article-title":"The American society of pain and neuroscience (ASPN) guidelines for radiofrequency ablative procedures in patients with implanted devices","volume":"16","author":"Sowder","year":"2023","journal-title":"J Pain Res"},{"issue":"4","key":"10.1016\/j.inpm.2026.100793_bib13","doi-asserted-by":"crossref","first-page":"493","DOI":"10.4103\/aca.ACA_191_19","article-title":"Anesthetic consideration for patients with micra leadless pacemaker","volume":"23","author":"Banik","year":"2020","journal-title":"Ann Card Anaesth"},{"issue":"4","key":"10.1016\/j.inpm.2026.100793_bib14","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1097\/ALN.0000000000002571","article-title":"Electromagnetic interference with protocolized electrosurgery dispersive electrode positioning in patients with implantable cardioverter defibrillators","volume":"130","author":"Schulman","year":"2019","journal-title":"Anesthesiology"},{"key":"10.1016\/j.inpm.2026.100793_bib15","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2021\/5559830","article-title":"Tricuspid valve replacement in a patient with a leadless cardiac pacemaker: current guidelines and recommendations for perioperative management","volume":"2021","author":"Hames","year":"2021","journal-title":"Case Reports in Anesthesiology"},{"issue":"6","key":"10.1016\/j.inpm.2026.100793_bib16","article-title":"Magnet use for implantable cardiac devices: a practical guide","volume":"44","author":"Montandrau","year":"2025","journal-title":"Anesth Crit Care Pain Med"},{"issue":"2","key":"10.1016\/j.inpm.2026.100793_bib17","first-page":"141","article-title":"Canadian cardiovascular society\/Canadian anesthesiologists' society\/Canadian heart rhythm society joint position statement on the perioperative management of patients with implanted pacemakers, defibrillators, and neurostimulating devices","volume":"28","author":"Healey","year":"2012","journal-title":"Can J Cardiol"}],"container-title":["Interventional Pain Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2772594426000580?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2772594426000580?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T11:49:21Z","timestamp":1782128961000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2772594426000580"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6]]},"references-count":17,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["S2772594426000580"],"URL":"https:\/\/doi.org\/10.1016\/j.inpm.2026.100793","relation":{},"ISSN":["2772-5944"],"issn-type":[{"value":"2772-5944","type":"print"}],"subject":[],"published":{"date-parts":[[2026,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Lumbar medial branch radiofrequency neurotomy in a patient with a leadless pacemaker: a case report","name":"articletitle","label":"Article Title"},{"value":"Interventional Pain Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.inpm.2026.100793","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Published by Elsevier Inc. on behalf of International Pain & Spine Intervention Society.","name":"copyright","label":"Copyright"}],"article-number":"100793"}}