{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T18:20:33Z","timestamp":1763058033211,"version":"build-2065373602"},"reference-count":18,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2017,4,1]],"date-time":"2017-04-01T00:00:00Z","timestamp":1491004800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,4,1]],"date-time":"2017-04-01T00:00:00Z","timestamp":1491004800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jaapos.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of American Association for Pediatric Ophthalmology and Strabismus"],"published-print":{"date-parts":[[2017,4]]},"DOI":"10.1016\/j.jaapos.2017.03.004","type":"journal-article","created":{"date-parts":[[2017,3,9]],"date-time":"2017-03-09T15:02:18Z","timestamp":1489071738000},"page":"103-106.e2","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Strabismus surgery outcomes in eyes with glaucoma drainage devices"],"prefix":"10.1016","volume":"21","author":[{"given":"Carla J.","family":"Osigian","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kara M.","family":"Cavuoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julia D.","family":"Rossetto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed","family":"Sayed","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sara","family":"Grace","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ta C.","family":"Chang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hilda","family":"Capo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jaapos.2017.03.004_bib1","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1023\/A:1016335313035","article-title":"Baerveldt implant in refractory glaucoma: long-term results and factors influencing outcome","volume":"24","author":"Roy","year":"2001","journal-title":"Int Ophthalmol"},{"key":"10.1016\/j.jaapos.2017.03.004_bib2","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/01.ijg.0000195597.30600.27","article-title":"Outcomes of inferonasal Baerveldt glaucoma drainage implant surgery","volume":"15","author":"Harbick","year":"2006","journal-title":"J\u00a0Glaucoma"},{"key":"10.1016\/j.jaapos.2017.03.004_bib3","doi-asserted-by":"crossref","first-page":"2312","DOI":"10.1016\/S0161-6420(99)90532-8","article-title":"Randomized clinical trial of the 350-mm2 versus the 500-mm2 Baerveldt implant: longer term results: is bigger better?","volume":"106","author":"Britt","year":"1999","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jaapos.2017.03.004_bib4","doi-asserted-by":"crossref","first-page":"1968","DOI":"10.1016\/S0161-6420(98)91049-1","article-title":"A\u00a0clinical study of the Ahmed glaucoma valve implant in advanced glaucoma","volume":"105","author":"Ayyala","year":"1998","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jaapos.2017.03.004_bib5","doi-asserted-by":"crossref","first-page":"1814","DOI":"10.1016\/S0161-6420(03)00574-8","article-title":"The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma: a single-surgeon comparison of outcome","volume":"110","author":"Tsai","year":"2003","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jaapos.2017.03.004_bib6","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/S0161-6420(00)00537-6","article-title":"Intermediate-term outcomes of 350-mm(2) Baerveldt glaucoma implants","volume":"108","author":"Krishna","year":"2001","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jaapos.2017.03.004_bib7","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1097\/ICU.0b013e32834ff2d1","article-title":"Tube Versus Trabeculectomy Study Group. The Tube Versus Trabeculectomy Study: interpretation of results and application to clinical practice","volume":"23","author":"Gedde","year":"2012","journal-title":"Curr Opin Ophthalmol"},{"key":"10.1016\/j.jaapos.2017.03.004_bib8","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1016\/S0161-6420(93)31554-X","article-title":"Early clinical experience with the Baerveldt 350-mm2 glaucoma implant and associated extraocular muscle imbalance","volume":"100","author":"Smith","year":"1993","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jaapos.2017.03.004_bib9","first-page":"192","article-title":"Diplopia after glaucoma drainage device implantation","volume":"17","author":"Abdelaziz","year":"2013","journal-title":"J\u00a0AAPOS"},{"key":"10.1016\/j.jaapos.2017.03.004_bib10","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1016\/j.ajo.2008.09.019","article-title":"Motility disturbances in the tube versus trabeculectomy study during the first year of follow-up","volume":"147","author":"Rauscher","year":"2009","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.jaapos.2017.03.004_bib11","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.ophtha.2016.10.006","article-title":"Diplopia in medically and surgically treated patients with glaucoma","volume":"124","author":"Sun","year":"2017","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jaapos.2017.03.004_bib12","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1016\/j.survophthal.2009.08.004","article-title":"Diplopia and strabismus following ocular surgeries","volume":"55","author":"Guo","year":"2010","journal-title":"Surv Ophthalmol"},{"key":"10.1016\/j.jaapos.2017.03.004_bib13","first-page":"608","article-title":"Pseudo-Brown's syndrome as a complication of glaucoma drainage implant surgery","volume":"24","author":"Prata","year":"1993","journal-title":"Ophthalmic Surg"},{"key":"10.1016\/j.jaapos.2017.03.004_bib14","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1001\/archopht.1993.01090080092023","article-title":"Strabismus following implantation of Baerveldt drainage devices","volume":"111","author":"Mu\u00f1oz","year":"1993","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.jaapos.2017.03.004_bib15","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.1001\/archopht.117.9.1155","article-title":"Prospective evaluation of extraocular motility following double-plate molteno implantation","volume":"117","author":"Dobler-Dixon","year":"1999","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.jaapos.2017.03.004_bib16","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1001\/archopht.126.4.480","article-title":"Surgical treatment of strabismus secondary to glaucoma drainage device","volume":"126","author":"Roizen","year":"2008","journal-title":"Arch Ophthalmol"},{"unstructured":"Rosenbaun A. Clinical Strabismus Management. In: Co PWS, editor. Clinical Strabismus Management1999. p. 304-7.","key":"10.1016\/j.jaapos.2017.03.004_bib17"},{"key":"10.1016\/j.jaapos.2017.03.004_bib18","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1111\/opo.12021","article-title":"Stereoacuity in mild, moderate and severe glaucoma","volume":"33","author":"Lakshmanan","year":"2013","journal-title":"Ophthalmic Physiol Opt"}],"container-title":["Journal of American Association for Pediatric Ophthalmology and Strabismus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1091853117301969?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1091853117301969?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T20:21:49Z","timestamp":1761078109000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1091853117301969"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4]]},"references-count":18,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017,4]]}},"alternative-id":["S1091853117301969"],"URL":"https:\/\/doi.org\/10.1016\/j.jaapos.2017.03.004","relation":{},"ISSN":["1091-8531"],"issn-type":[{"type":"print","value":"1091-8531"}],"subject":[],"published":{"date-parts":[[2017,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Strabismus surgery outcomes in eyes with glaucoma drainage devices","name":"articletitle","label":"Article Title"},{"value":"Journal of American Association for Pediatric Ophthalmology and Strabismus","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jaapos.2017.03.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017, American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}