{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T20:47:39Z","timestamp":1761166059823,"version":"build-2065373602"},"reference-count":23,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2022,10,1]],"date-time":"2022-10-01T00:00:00Z","timestamp":1664582400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,10,1]],"date-time":"2022-10-01T00:00:00Z","timestamp":1664582400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jaapos.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of American Association for Pediatric Ophthalmology and Strabismus"],"published-print":{"date-parts":[[2022,10]]},"DOI":"10.1016\/j.jaapos.2022.06.003","type":"journal-article","created":{"date-parts":[[2022,9,16]],"date-time":"2022-09-16T11:59:19Z","timestamp":1663329559000},"page":"232.e1-232.e7","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Outcomes of inferonasal glaucoma drainage device surgery in the management of childhood glaucoma"],"prefix":"10.1016","volume":"26","author":[{"given":"Amal","family":"Al-Lozi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Allison C.","family":"Umfress","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandra S.","family":"Stinnett","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sharon F.","family":"Freedman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jaapos.2022.06.003_bib1","doi-asserted-by":"crossref","first-page":"e189","DOI":"10.1097\/IJG.0000000000000164","article-title":"The Long-term outcomes of glaucoma drainage device in pediatric glaucoma","volume":"25","author":"Mandalos","year":"2016","journal-title":"J\u00a0Glaucoma"},{"year":"2013","series-title":"The 9th Consensus Report of the World Glaucoma Association","author":"Weinreb","key":"10.1016\/j.jaapos.2022.06.003_bib2"},{"key":"10.1016\/j.jaapos.2022.06.003_bib3","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1097\/IJG.0b013e318287ac8f","article-title":"Surgical outcomes of superior versus inferior glaucoma drainage device implantation","volume":"24","author":"Martino","year":"2015","journal-title":"J\u00a0Glaucoma"},{"key":"10.1016\/j.jaapos.2022.06.003_bib4","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/01.ijg.0000195597.30600.27","article-title":"Outcomes of inferonasal Baerveldt glaucoma drainage implant surgery","volume":"15","author":"Harbick","year":"2006","journal-title":"J\u00a0Glaucoma"},{"key":"10.1016\/j.jaapos.2022.06.003_bib5","first-page":"590","article-title":"Results of Ahmed glaucoma valve implantation in primary congenital glaucoma","volume":"18","author":"Razeghinejad","year":"2014","journal-title":"J\u00a0AAPOS"},{"key":"10.1016\/j.jaapos.2022.06.003_bib6","doi-asserted-by":"crossref","unstructured":"Djodeyre MR, Peralta Calvo J, Abelairas Gomez J. Clinical evaluation and risk factors of time to failure of Ahmed glaucoma valve implant in pediatric patients. Ophthalmology 2001;108:614-620.","DOI":"10.1016\/S0161-6420(00)00603-5"},{"key":"10.1016\/j.jaapos.2022.06.003_bib7","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1136\/bjo.2005.078832","article-title":"Baerveldt glaucoma implant in paediatric patients","volume":"90","author":"van Overdam","year":"2006","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.jaapos.2022.06.003_bib8","doi-asserted-by":"crossref","first-page":"2204","DOI":"10.1016\/j.ophtha.2004.05.017","article-title":"Baerveldt glaucoma implant in the management of refractory childhood glaucomas","volume":"111","author":"Budenz","year":"2004","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jaapos.2022.06.003_bib9","doi-asserted-by":"crossref","first-page":"2107","DOI":"10.1016\/j.ophtha.2014.05.010","article-title":"Pediatric glaucoma surgery: a report by the American Academy Of Ophthalmology","volume":"121","author":"Chen","year":"2014","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jaapos.2022.06.003_bib10","first-page":"145.e1","article-title":"Risk factors for strabismus following glaucoma drainage device implantation for refractory childhood glaucoma","volume":"23","author":"Talsania","year":"2019","journal-title":"J\u00a0AAPOS"},{"key":"10.1016\/j.jaapos.2022.06.003_bib11","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.ajo.2020.12.003","article-title":"Surgical outcomes of superotemporal versus inferonasal placement of aurolab aqueous drainage implant in refractory pediatric glaucoma","volume":"224","author":"Puthuran","year":"2020","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.jaapos.2022.06.003_bib12","first-page":"39","article-title":"Staying away from the optic nerve: a formula for modifying glaucoma drainage device surgery in pediatric and other small eyes","volume":"21","author":"Margeta","year":"2017","journal-title":"J\u00a0AAPOS"},{"key":"10.1016\/j.jaapos.2022.06.003_bib13","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/0002-9394(82)90197-0","article-title":"New visual acuity charts for clinical research","volume":"94","author":"Ferris","year":"1982","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.jaapos.2022.06.003_bib14","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1136\/bjophthalmol-2019-315558","article-title":"Comparison of outcomes between Aurolab aqueous drainage implant placed in the superotemporal versus inferonasal quadrant","volume":"105","author":"Puthuran","year":"2021","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.jaapos.2022.06.003_bib15","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.ajo.2014.03.017","article-title":"Second glaucoma drainage devices in refractory pediatric glaucoma: failure by fibrovascular ingrowth","volume":"158","author":"Tung","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.jaapos.2022.06.003_bib16","first-page":"346.e1","article-title":"Long-term outcomes of the Ahmed glaucoma valve surgery in childhood glaucoma","volume":"24","author":"Mofti","year":"2020","journal-title":"J\u00a0AAPOS"},{"key":"10.1016\/j.jaapos.2022.06.003_bib17","doi-asserted-by":"crossref","first-page":"928","DOI":"10.1177\/112067210701700610","article-title":"Glaucoma drainage implants in the treatment of refractory glaucoma in pediatric patients","volume":"17","author":"Autrata","year":"2007","journal-title":"Eur J Ophthalmol"},{"key":"10.1016\/j.jaapos.2022.06.003_bib18","first-page":"515","article-title":"Long-term home monitoring of intraocular pressure in pediatric glaucoma","volume":"20","author":"Bitner","year":"2016","journal-title":"J\u00a0AAPOS Dec"},{"key":"10.1016\/j.jaapos.2022.06.003_bib19","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1016\/S0161-6420(93)31554-X","article-title":"Early clinical experience with the Baerveldt 350-mm2 glaucoma implant and associated extraocular muscle imbalance","volume":"100","author":"Smith","year":"1993","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jaapos.2022.06.003_bib20","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1016\/S0161-6420(03)00088-5","article-title":"Intermediate-term outcome of Baerveldt glaucoma implants in Asian eyes","volume":"110","author":"Seah","year":"2003","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jaapos.2022.06.003_bib21","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1136\/bjo.2004.049015","article-title":"Endophthalmitis associated with the Ahmed glaucoma valve implant","volume":"89","author":"Al-Torbak","year":"2005","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.jaapos.2022.06.003_bib22","doi-asserted-by":"crossref","first-page":"977","DOI":"10.2147\/OPTH.S83820","article-title":"Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure","volume":"9","author":"Huang","year":"2015","journal-title":"Clin Ophthalmol"},{"key":"10.1016\/j.jaapos.2022.06.003_bib23","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1007\/s00417-017-3584-2","article-title":"Glaucoma drainage device surgery in children and adults: a comparative study of outcomes and complications","volume":"255","author":"Mandalos","year":"2017","journal-title":"Graefes Arch Clin Exp Ophthalmol"}],"container-title":["Journal of American Association for Pediatric Ophthalmology and Strabismus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1091853122004311?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1091853122004311?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T20:25:43Z","timestamp":1761078343000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1091853122004311"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10]]},"references-count":23,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,10]]}},"alternative-id":["S1091853122004311"],"URL":"https:\/\/doi.org\/10.1016\/j.jaapos.2022.06.003","relation":{},"ISSN":["1091-8531"],"issn-type":[{"type":"print","value":"1091-8531"}],"subject":[],"published":{"date-parts":[[2022,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Outcomes of inferonasal glaucoma drainage device surgery in the management of childhood glaucoma","name":"articletitle","label":"Article Title"},{"value":"Journal of American Association for Pediatric Ophthalmology and Strabismus","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jaapos.2022.06.003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}