{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T13:27:01Z","timestamp":1794230821032,"version":"4.9.0"},"reference-count":19,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:00:00Z","timestamp":1791331200000},"content-version":"vor","delay-in-days":6,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000053","name":"National Eye Institute","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000053","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100019367","name":"Seva Foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100019367","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100001818","name":"Research to Prevent Blindness","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100001818","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100017433","name":"All May See Foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100017433","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jaapos.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of American Association for Pediatric Ophthalmology and Strabismus"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.jaapos.2026.105318","type":"journal-article","created":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T16:06:55Z","timestamp":1791562015000},"page":"105318","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Assessment of the Spot vision screener performance in detecting amblyopia and strabismus in Nepal: a prospective diagnostic accuracy study"],"prefix":"10.1016","volume":"30","author":[{"given":"Manisha","family":"Shrestha","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gopal","family":"Bhandari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sadhan","family":"Bhandari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jocelyn","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Krisianne","family":"Aromin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gui-Shuang","family":"Ying","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeremy D.","family":"Keenan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3945-2077","authenticated-orcid":false,"given":"Julius T.","family":"Oatts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jaapos.2026.105318_bib1","doi-asserted-by":"crossref","first-page":"e144","DOI":"10.1016\/S2214-109X(20)30489-7","article-title":"Causes of blindness and vision impairment in 2020 and trends over 30 years, and prevalence of avoidable blindness in relation to VISION 2020: the Right to Sight: an analysis for the Global Burden of Disease Study","volume":"9","author":"Steinmetz","year":"2021","journal-title":"Lancet Glob Health"},{"key":"10.1016\/j.jaapos.2026.105318_bib2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1471-2415-14-125","article-title":"Factors associated with childhood ocular morbidity and blindness in three ecological regions of Nepal: Nepal pediatric ocular disease study","volume":"14","author":"Adhikari","year":"2014","journal-title":"BMC Ophthalmol"},{"key":"10.1016\/j.jaapos.2026.105318_bib3","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.jaapos.2013.11.019","article-title":"Performance of the Spot vision screener for the detection of amblyopia risk factors in children","volume":"18","author":"Silbert","year":"2014","journal-title":"J AAPOS"},{"key":"10.1016\/j.jaapos.2026.105318_bib4","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1016\/j.jaapos.2014.07.176","article-title":"The effectiveness of the Spot Vision Screener in detecting amblyopia risk factors","volume":"18","author":"Peterseim","year":"2014","journal-title":"J AAPOS"},{"key":"10.1016\/j.jaapos.2026.105318_bib5","doi-asserted-by":"crossref","first-page":"153.e1","DOI":"10.1016\/j.jaapos.2018.09.012","article-title":"Evaluation of the Spot Vision Screener for children with limited access to ocular health care","volume":"23","author":"Barugel","year":"2019","journal-title":"J AAPOS"},{"key":"10.1016\/j.jaapos.2026.105318_bib6","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.jaapos.2015.08.002","article-title":"Evaluation of the spot vision screener in young children in Costa Rica","volume":"19","author":"Mendez","year":"2015","journal-title":"J AAPOS"},{"key":"10.1016\/j.jaapos.2026.105318_bib7","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2016-012799","article-title":"STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration","volume":"6","author":"Cohen","year":"2016","journal-title":"BMJ Open"},{"issue":"1","key":"10.1016\/j.jaapos.2026.105318_bib8","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.jaapos.2021.09.009","article-title":"AAPOS Vision Screening and Research Committees. AAPOS uniform guidelines for instrument-based pediatric vision screen validation 2021","volume":"26","author":"Arnold","year":"2022","journal-title":"J AAPOS"},{"key":"10.1016\/j.jaapos.2026.105318_bib9","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/j.jaapos.2007.08.014","article-title":"Normative pediatric visual acuity using single surrounded HOTV optotypes on the Electronic Visual Acuity Tester following the Amblyopia Treatment Study protocol","volume":"12","author":"Drover","year":"2008","journal-title":"J AAPOS"},{"key":"10.1016\/j.jaapos.2026.105318_bib10","doi-asserted-by":"crossref","first-page":"1343","DOI":"10.1016\/S0140-6736(06)68581-4","article-title":"Amblyopia","volume":"367","author":"Holmes","year":"2006","journal-title":"Lancet"},{"key":"10.1016\/j.jaapos.2026.105318_bib11","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0251583","article-title":"Accuracy of autorefraction in an adult Indian population","volume":"16","author":"Kumar","year":"2021","journal-title":"PLoS One"},{"key":"10.1016\/j.jaapos.2026.105318_bib12","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.jaapos.2012.09.012","article-title":"Guidelines for automated preschool vision screening: a 10-year, evidence-based update","volume":"17","author":"Donahue","year":"2013","journal-title":"J AAPOS"},{"key":"10.1016\/j.jaapos.2026.105318_bib13","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2019-032138","article-title":"Choosing appropriate tools and referral criteria for vision screening of children aged 4-5 years in Canada: a quantitative analysis","volume":"9","author":"Nishimura","year":"2019","journal-title":"BMJ Open"},{"key":"10.1016\/j.jaapos.2026.105318_bib14","doi-asserted-by":"crossref","first-page":"91","DOI":"10.15406\/aovs.2020.10.00392","article-title":"School vision screening programmes in reducing uncorrected refractive error among children in low and middle-income countries-LMIC (systematic review)","volume":"10","author":"Opare","year":"2020","journal-title":"Adv Ophthalmol Vis Syst"},{"key":"10.1016\/j.jaapos.2026.105318_bib15","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1016\/j.jaapos.2014.07.156","article-title":"Validation of Spot screening device for amblyopia risk factors","volume":"18","author":"Garry","year":"2014","journal-title":"J AAPOS"},{"key":"10.1016\/j.jaapos.2026.105318_bib16","doi-asserted-by":"crossref","first-page":"146","DOI":"10.3928\/01913913-20200331-02","article-title":"Evaluation of the Spot Vision Screener in school-aged children","volume":"57","author":"Peterseim","year":"2020","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"10.1016\/j.jaapos.2026.105318_bib17","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1136\/bjophthalmol-2018-311885","article-title":"Compared performance of Spot and SW800 photoscreeners on Chinese children","volume":"103","author":"Qian","year":"2019","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.jaapos.2026.105318_bib18","doi-asserted-by":"crossref","first-page":"128","DOI":"10.3126\/nepjoph.v3i2.5264","article-title":"Validation of performance of certified medical assistants in preschool vision screening examination","volume":"3","author":"Adhikari","year":"2011","journal-title":"Nepal J Ophthalmol"},{"key":"10.1016\/j.jaapos.2026.105318_bib19","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1016\/j.jaapos.2015.09.003","article-title":"Detection of strabismus by the spot vision screener","volume":"19","author":"Peterseim","year":"2015","journal-title":"J AAPOS"}],"container-title":["Journal of American Association for Pediatric Ophthalmology and Strabismus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1091853126005914?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1091853126005914?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T12:55:43Z","timestamp":1794228943000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1091853126005914"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["S1091853126005914"],"URL":"https:\/\/doi.org\/10.1016\/j.jaapos.2026.105318","relation":{},"ISSN":["1091-8531"],"issn-type":[{"value":"1091-8531","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Assessment of the Spot vision screener performance in detecting amblyopia and strabismus in Nepal: a prospective diagnostic accuracy study","name":"articletitle","label":"Article Title"},{"value":"Journal of American Association for Pediatric Ophthalmology and Strabismus","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jaapos.2026.105318","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Inc. on behalf of the American Association for Pediatric Ophthalmology and Strabismus.","name":"copyright","label":"Copyright"}],"article-number":"105318"}}