{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T06:56:16Z","timestamp":1789541776088,"version":"build-2803163510"},"reference-count":44,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T00:00:00Z","timestamp":1740441600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Basic to Translational Science"],"published-print":{"date-parts":[[2025,9]]},"DOI":"10.1016\/j.jacbts.2025.02.013","type":"journal-article","created":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T18:54:11Z","timestamp":1753901651000},"page":"101254","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["The Past, Present, and Promising Future of Direct Cardiac Compression Devices"],"prefix":"10.1016","volume":"10","author":[{"given":"Melanie P.","family":"Hager","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-1239-2973","authenticated-orcid":false,"given":"Paulamy","family":"Ganguly","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George V.","family":"Letsou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacbts.2025.02.013_bib1","doi-asserted-by":"crossref","first-page":"e67","DOI":"10.1161\/CIR.0000000000000558","article-title":"Heart Disease and stroke statistics-2018 update: a report from the American Heart Association","volume":"137","author":"Benjamin","year":"2018","journal-title":"Circulation"},{"key":"10.1016\/j.jacbts.2025.02.013_bib2","doi-asserted-by":"crossref","unstructured":"Rose EA, Gelijns AC, Moskowitz AJ, et al. Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med. 2001;345:1435-1443.","DOI":"10.1056\/NEJMoa012175"},{"key":"10.1016\/j.jacbts.2025.02.013_bib3","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.119.006082","article-title":"Sex-based differences in left ventricular assist device utilization: insights from the Nationwide Inpatient Sample 2004 to 2016","volume":"12","author":"Joshi","year":"2019","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.jacbts.2025.02.013_bib4","unstructured":"Tossach WA. A man dead in appearance, recovered by distending the lungs with air. Medical Essays and Observations. 1744;5:605-608."},{"key":"10.1016\/j.jacbts.2025.02.013_bib5","first-page":"200","article-title":"Ueber direkte reizung der herzoberfl\u00e4che","volume":"28","author":"Schiff","year":"1882","journal-title":"Archiv f\u00fcr die gesamte Physiologie des Menschen und der Tiere"},{"key":"10.1016\/j.jacbts.2025.02.013_bib6","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1007\/BF01831354","article-title":"Ueber wiederbelebung nach vergiftungen und asphyxie","volume":"8","author":"Boehm","year":"1877","journal-title":"Archiv f\u00fcr experimentelle Pathologie und Pharmakologie"},{"key":"10.1016\/j.jacbts.2025.02.013_bib7","series-title":"Blood-pressure in surgery: an experimental and clinical research; the Cartwright Prize Essay for 1903","author":"Crile","year":"1903"},{"key":"10.1016\/j.jacbts.2025.02.013_bib8","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1056\/NEJM195411112512001","article-title":"Cardiac arrest: results of attempted cardiac resuscitation in 42 cases","volume":"251","author":"Turk III","year":"1954","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jacbts.2025.02.013_bib9","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.1001\/jama.1960.03020280004002","article-title":"Closed-chest cardiac massage","volume":"173","author":"Kouwenhoven","year":"1960","journal-title":"JAMA"},{"key":"10.1016\/j.jacbts.2025.02.013_bib10","first-page":"375","article-title":"The pneumo-massage of the heart; experimental research","volume":"39","author":"Bencini","year":"1956","journal-title":"Surgery"},{"key":"10.1016\/j.jacbts.2025.02.013_bib11","first-page":"72","article-title":"Prolonged circulatory support by direct mechanical ventricular assistance","volume":"12","author":"Anstadt","year":"1966","journal-title":"Trans Am Soc Artif Intern Organs"},{"key":"10.1016\/j.jacbts.2025.02.013_bib12","doi-asserted-by":"crossref","first-page":"II33","DOI":"10.1161\/01.CIR.37.4S2.II-33","article-title":"Mechanical ventricular assistance in man","volume":"37","author":"Baue","year":"1968","journal-title":"Circulation"},{"key":"10.1016\/j.jacbts.2025.02.013_bib13","first-page":"174","article-title":"Prolonged circulatory support by direct mechanical ventricular assistance for two to three days of ventricular fibrillation","volume":"17","author":"Anstadt","year":"1971","journal-title":"Trans Am Soc Artif Intern Organs"},{"key":"10.1016\/j.jacbts.2025.02.013_bib14","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1016\/S0196-0644(84)80433-3","article-title":"Comparative study of 3 methods of resuscitation: closed-chest, open-chest manual, and direct mechanical ventricular assistance","volume":"13","author":"Bartlett","year":"1984","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.jacbts.2025.02.013_bib15","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1378\/chest.100.1.86","article-title":"Direct mechanical ventricular actuation for cardiac arrest in humans. A clinical feasibility trial","volume":"100","author":"Anstadt","year":"1991","journal-title":"Chest"},{"key":"10.1016\/j.jacbts.2025.02.013_bib16","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/0300-9572(91)90074-9","article-title":"Direct mechanical ventricular actuation: a review","volume":"21","author":"Anstadt","year":"1991","journal-title":"Resuscitation"},{"key":"10.1016\/j.jacbts.2025.02.013_bib17","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1097\/00002480-199642040-00012","article-title":"Experimental aortocoronary saphenous vein graft function after mechanical cardiac massage with the Anstadt Cup","volume":"42","author":"Anstadt","year":"1996","journal-title":"ASAIO J"},{"key":"10.1016\/j.jacbts.2025.02.013_bib18","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1016\/S0003-4975(99)00524-X","article-title":"Heart booster: a pericardial support device","volume":"68","author":"Kung","year":"1999","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jacbts.2025.02.013_bib19","doi-asserted-by":"crossref","first-page":"II-236","DOI":"10.1161\/circ.100.suppl_2.Ii-236","article-title":"Physiological and hemodynamic evaluation of nonuniform direct cardiac compression","volume":"100","author":"Artrip","year":"1999","journal-title":"Circulation"},{"key":"10.1016\/j.jacbts.2025.02.013_bib20","doi-asserted-by":"crossref","first-page":"2177","DOI":"10.1161\/01.CIR.99.16.2177","article-title":"Hemodynamic effects of direct biventricular compression studied in isovolumic and ejecting isolated canine hearts","volume":"99","author":"Artrip","year":"1999","journal-title":"Circulation"},{"key":"10.1016\/j.jacbts.2025.02.013_bib21","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1067\/mtc.2000.106986","article-title":"Maximizing hemodynamic effectiveness of biventricular assistance by direct cardiac compression studied in ex vivo and in vivo canine models of acute heart failure","volume":"120","author":"Artrip","year":"2000","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jacbts.2025.02.013_bib22","doi-asserted-by":"crossref","first-page":"S188","DOI":"10.1016\/S0003-4975(00)02619-9","article-title":"Direct cardiac compression for cardiogenic shock with the CardioSupport system","volume":"71","author":"Williams","year":"2001","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jacbts.2025.02.013_bib23","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1067\/mtc.2001.115929","article-title":"Circulatory support with a direct cardiac compression device: a less invasive approach with the AbioBooster device","volume":"122","author":"Kavarana","year":"2001","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jacbts.2025.02.013_bib24","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1016\/S0003-4975(01)03467-1","article-title":"Non-blood contacting biventricular support for severe heart failure","volume":"73","author":"Anstadt","year":"2002","journal-title":"Ann Thorac Surg"},{"issue":"2","key":"10.1016\/j.jacbts.2025.02.013_bib25","article-title":"Pediatric mechanical support with an external cardiac compression device","volume":"1","author":"Kavarana","year":"2013","journal-title":"J Cardiovasc Dis Diagn"},{"key":"10.1016\/j.jacbts.2025.02.013_bib26","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1097\/MAT.0000000000000147","article-title":"Cardiac function after acute support with direct mechanical ventricular actuation in chronic heart failure","volume":"60","author":"McConnell","year":"2014","journal-title":"ASAIO J"},{"key":"10.1016\/j.jacbts.2025.02.013_bib27","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.jtcvs.2010.05.057","article-title":"Nonsurround, nonuniform, biventricular-capable direct cardiac compression provides Frank-Starling recruitment independent of left ventricular septal damage","volume":"142","author":"Mau","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jacbts.2025.02.013_bib28","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1111\/j.1525-1594.2007.00338.x","article-title":"Efficacy and mechanisms of biventricular and left\/right direct cardiac compression in acute heart failure sheep","volume":"31","author":"Gallagher","year":"2007","journal-title":"Artif Organs"},{"key":"10.1016\/j.jacbts.2025.02.013_bib29","doi-asserted-by":"crossref","first-page":"1944","DOI":"10.1016\/j.athoracsur.2022.06.052","article-title":"Mechanical cardiac support with an implantable direct cardiac compression device: proof of concept","volume":"114","author":"Letsou","year":"2022","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jacbts.2025.02.013_bib30","doi-asserted-by":"crossref","first-page":"S411","DOI":"10.1016\/j.healun.2023.02.1066","article-title":"(955) A New implantable direct cardiac compression device improves cardiac performance in a chronic ovine heart failure model","volume":"42","author":"Letsou","year":"2023","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.jacbts.2025.02.013_bib31","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1007\/s12265-018-9854-5","article-title":"Evaluation of the CorInnova heart assist device in an acute heart failure model","volume":"12","author":"Hord","year":"2019","journal-title":"J Cardiovasc Transl Res"},{"issue":"2","key":"10.1016\/j.jacbts.2025.02.013_bib32","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1007\/s13239-023-00703-0","article-title":"Preclinical proof-of-concept of a minimally invasive direct cardiac compression device for pediatric heart support","volume":"15","author":"Hord","year":"2024","journal-title":"Cardiovasc Eng Technol"},{"key":"10.1016\/j.jacbts.2025.02.013_bib33","doi-asserted-by":"crossref","first-page":"588","DOI":"10.5301\/ijao.5000447","article-title":"Direct epicardial assist device using artificial rubber muscle in a swine model of pediatric dilated cardiomyopathy","volume":"38","author":"Saito","year":"2015","journal-title":"Int J Artif Organs"},{"issue":"4","key":"10.1016\/j.jacbts.2025.02.013_bib34","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1016\/j.jtcvs.2021.11.093","article-title":"A novel intrapericardial pulsatile device for individualized, biventricular circulatory support without direct blood contact","volume":"166","author":"Schueler","year":"2023","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jacbts.2025.02.013_bib35","article-title":"German start-up AdjuCor marks milestone with successful first-in-human implantations of reBEAT System","author":"deVaal","year":"2023","journal-title":"PRWeb"},{"key":"10.1016\/j.jacbts.2025.02.013_bib36","doi-asserted-by":"crossref","first-page":"1534","DOI":"10.1007\/s10439-018-2046-2","article-title":"Towards alternative approaches for coupling of a soft robotic sleeve to the heart","volume":"46","author":"Horvath","year":"2018","journal-title":"Ann Biomed Eng"},{"key":"10.1016\/j.jacbts.2025.02.013_bib37","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1146\/annurev-bioeng-110220-025309","article-title":"Direct cardiac compression devices to augment heart biomechanics and function","volume":"24","author":"Bonnemain","year":"2022","journal-title":"Ann Rev Biomed Eng"},{"key":"10.1016\/j.jacbts.2025.02.013_bib38","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1089\/soro.2016.0076","article-title":"An implantable extracardiac soft robotic device for the failing heart: mechanical coupling and synchronization","volume":"4","author":"Payne","year":"2017","journal-title":"Soft Robot"},{"key":"10.1016\/j.jacbts.2025.02.013_bib39","first-page":"121","article-title":"Dynamic cardiomyoplasty","volume":"13","author":"Letsou","year":"1995","journal-title":"Cardiol Clin"},{"key":"10.1016\/j.jacbts.2025.02.013_bib40","first-page":"125","article-title":"Skeletal muscle for cardiac assist","volume":"13","author":"Letsou","year":"1995","journal-title":"Cardiol Clin"},{"key":"10.1016\/j.jacbts.2025.02.013_bib41","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1016\/S0003-4975(99)00454-3","article-title":"Dynamic cardiomyoplasty: at the crossroads","volume":"68","author":"Acker","year":"1999","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jacbts.2025.02.013_bib42","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1016\/S0022-5223(03)00049-7","article-title":"Global surgical experience with the Acorn cardiac support device","volume":"126","author":"Oz","year":"2003","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jacbts.2025.02.013_bib43","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1016\/j.jtcvs.2011.06.014","article-title":"Beneficial effects of the CorCap cardiac support device: five-year results from the Acorn Trial","volume":"143","author":"Mann","year":"2012","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jacbts.2025.02.013_bib45","author":"Meyer"}],"container-title":["JACC: Basic to Translational Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2452302X25000713?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2452302X25000713?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T17:07:02Z","timestamp":1767719222000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2452302X25000713"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9]]},"references-count":44,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["S2452302X25000713"],"URL":"https:\/\/doi.org\/10.1016\/j.jacbts.2025.02.013","relation":{},"ISSN":["2452-302X"],"issn-type":[{"value":"2452-302X","type":"print"}],"subject":[],"published":{"date-parts":[[2025,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The Past, Present, and Promising Future of Direct Cardiac Compression Devices","name":"articletitle","label":"Article Title"},{"value":"JACC: Basic to Translational Science","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jacbts.2025.02.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.","name":"copyright","label":"Copyright"}],"article-number":"101254"}}