{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T02:48:37Z","timestamp":1789958917985,"version":"4.0.1"},"reference-count":47,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2006,1,1]],"date-time":"2006-01-01T00:00:00Z","timestamp":1136073600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2013,7,16]],"date-time":"2013-07-16T00:00:00Z","timestamp":1373932800000},"content-version":"vor","delay-in-days":2753,"URL":"https:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of the American College of Cardiology"],"published-print":{"date-parts":[[2006,1]]},"DOI":"10.1016\/j.jacc.2005.05.100","type":"journal-article","created":{"date-parts":[[2005,12,10]],"date-time":"2005-12-10T09:06:00Z","timestamp":1134205560000},"page":"131-137","source":"Crossref","is-referenced-by-count":51,"title":["Flow-Dependent Changes in Doppler-Derived Aortic Valve Effective Orifice Area Are Real and Not Due to Artifact"],"prefix":"10.1016","volume":"47","author":[{"given":"Lyes","family":"Kadem","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R\u00e9gis","family":"Rieu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean G.","family":"Dumesnil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Louis-Gilles","family":"Durand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"Pibarot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacc.2005.05.100_bib1","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/S0002-9149(00)80078-8","article-title":"Usefulness of dobutamine echocardiography in distinguishing severe from nonsevere valvular aortic stenosis in patients with depressed left ventricular function and low transvalvular gradients","volume":"75","author":"deFilippi","year":"1995","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib2","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1007\/s11936-003-0036-6","article-title":"Low gradient, low ejection fraction aortic stenosis","volume":"5","author":"Chambers","year":"2003","journal-title":"Curr Treat Options Cardiovasc Med"},{"key":"10.1016\/j.jacc.2005.05.100_bib3","doi-asserted-by":"crossref","first-page":"1766","DOI":"10.1378\/chest.119.6.1766","article-title":"Dobutamine echocardiography in patients with aortic stenosis and left ventricular dysfunction","volume":"119","author":"Schwammenthal","year":"2001","journal-title":"Chest"},{"key":"10.1016\/j.jacc.2005.05.100_bib4","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1161\/01.CIR.0000079171.43055.46","article-title":"Low-gradient aortic stenosis: operative risk stratification and predictors for long-term outcome: a multicenter study using dobutamine stress hemodynamics","volume":"108","author":"Monin","year":"2003","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2005.05.100_bib5","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1161\/01.CIR.0000025611.21140.34","article-title":"Low-output, low-gradient aortic stenosis in patients with depressed left ventricular systolic function","volume":"106","author":"Nishimura","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2005.05.100_bib6","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1161\/01.CIR.97.16.1597","article-title":"Analysis of the effect of flow rate on the Doppler continuity equation for stenotic orifice area calculation. A numerical study","volume":"97","author":"DeGroff","year":"1998","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2005.05.100_bib7","series-title":"In vitro measurement of the vena contracta for stenotic valves using laser induced fluorescence imaging and digital particle image velocimetry","author":"Shandas","year":"1996"},{"key":"10.1016\/j.jacc.2005.05.100_bib8","first-page":"985","article-title":"Aortic valve area discrepancy by Gorlin equation and Doppler echocardiography continuity equation","volume":"16","author":"Burwash","year":"2000","journal-title":"Can J Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib9","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1177\/039139889501800706","article-title":"Ventricular flow dynamics past bileaflet prosthetic heart valves","volume":"7","author":"Garitey","year":"1995","journal-title":"Int J Artif Organs"},{"key":"10.1016\/j.jacc.2005.05.100_bib10","first-page":"615","article-title":"Independent contribution of the left ventricular ejection time to the mean gradient in aortic stenosis","volume":"11","author":"Kadem","year":"2002","journal-title":"J Heart Valve Dis"},{"key":"10.1016\/j.jacc.2005.05.100_bib11","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1088\/0957-0233\/1\/11\/013","article-title":"Optimization of particle image velocimeter. Part 1: double pulsed systems","volume":"1","author":"Keane","year":"1990","journal-title":"Meas Sci Technol"},{"key":"10.1016\/j.jacc.2005.05.100_bib12","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1146\/annurev.fl.23.010191.001401","article-title":"Particle imaging techniques for experimental fluid mechanics","volume":"23","author":"Adrian","year":"1991","journal-title":"Annu Rev Fluid Mechanics"},{"key":"10.1016\/j.jacc.2005.05.100_bib13","doi-asserted-by":"crossref","first-page":"1398","DOI":"10.1088\/0957-0233\/12\/9\/304","article-title":"Extension of PIV to super resolution using PTV","volume":"12","author":"Stitou","year":"2001","journal-title":"Meas Sci Technol"},{"key":"10.1016\/j.jacc.2005.05.100_bib14","series-title":"Experiments in Fluids","article-title":"A new experimental technique for the determination of the effective orifice area based on the acoustical term source","author":"Kadem","year":"2005"},{"key":"10.1016\/j.jacc.2005.05.100_bib15","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1006\/jsvi.2002.5001","article-title":"Experimental study of noise produced by steady flow through a simulated vascular stenosis","volume":"256","author":"Borisyuk","year":"2002","journal-title":"J Sound Vib"},{"key":"10.1016\/j.jacc.2005.05.100_bib16","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1098\/rspa.1952.0060","article-title":"On the sound generated aerodynamically: I. General theory","volume":"A221","author":"Lighthill","year":"1952","journal-title":"Proc R Soc London"},{"key":"10.1016\/j.jacc.2005.05.100_bib17","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1121\/1.1918931","article-title":"Theory of vortex sound","volume":"36","author":"Powell","year":"1964","journal-title":"J Acoust Soc Am"},{"key":"10.1016\/j.jacc.2005.05.100_bib18","series-title":"Theory of Vortex Sound","author":"Howe","year":"2002"},{"key":"10.1016\/j.jacc.2005.05.100_bib19","series-title":"Introduction to fluid dynamics","author":"Batchelor","year":"1967"},{"key":"10.1016\/j.jacc.2005.05.100_bib20","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1016\/0021-9290(76)90097-X","article-title":"The fluid mechanics of aortic stenosis II. Unsteady flow experiments","volume":"9","author":"Clark","year":"1976","journal-title":"J Biomech"},{"key":"10.1016\/j.jacc.2005.05.100_bib21","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1161\/01.CIR.91.4.1196","article-title":"Comparison of valvular resistance, stroke work loss, and Gorlin valve area for quantification of aortic stenosis. An in vitro study in a pulsatile aortic flow model","volume":"91","author":"Voelker","year":"1995","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2005.05.100_bib22","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1016\/S0735-1097(85)80127-3","article-title":"Variable effects of changes in flow rate through the aortic pulmonary and mitral valves on valve area and flow velocity","volume":"6","author":"Stewart","year":"1985","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib23","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1016\/S0002-9149(96)00528-0","article-title":"Changes in effective aortic valve area during ejection in adults with aortic stenosis","volume":"78","author":"Badano","year":"1996","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib24","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.1016\/S0735-1097(96)00287-2","article-title":"Effects of dobutamine on Doppler echocardiographic indexes of aortic stenosis","volume":"28","author":"Bermejo","year":"1996","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib25","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/S0002-9149(01)01584-3","article-title":"Comparison of valve resistance with effective orifice area regarding flow dependence","volume":"1","author":"Blais","year":"2001","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib26","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1161\/01.CIR.89.2.827","article-title":"Dependence of Gorlin formula and continuity equation valve areas on transvalvular volume flow rate in valvular aortic stenosis","volume":"89","author":"Burwash","year":"1994","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2005.05.100_bib27","doi-asserted-by":"crossref","first-page":"1342","DOI":"10.1016\/0735-1097(94)90118-X","article-title":"Flow dependence of measures of aortic stenosis severity during exercise","volume":"24","author":"Burwash","year":"1994","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib28","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.1016\/0002-9149(92)90051-Y","article-title":"Effects of dobutamine on Gorlin and continuity equation valve areas and valve resistance in valvular aortic stenosis","volume":"70","author":"Casale","year":"1992","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib29","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1136\/hrt.67.2.193","article-title":"Continuity equation and Gorlin formula compared with directly observed orifice area in native and prosthetic aortic valves","volume":"67","author":"Chambers","year":"1992","journal-title":"Br Heart J"},{"key":"10.1016\/j.jacc.2005.05.100_bib30","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1016\/0002-9149(89)90087-8","article-title":"Factors affecting Doppler echocardiographic valve area assessment in aortic stenosis","volume":"63","author":"Danielsen","year":"1989","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib31","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/0002-8703(92)90628-9","article-title":"Variation in Doppler-derived stenotic aortic valve area during ejection","volume":"124","author":"Lloyd","year":"1992","journal-title":"Am Heart J"},{"key":"10.1016\/j.jacc.2005.05.100_bib32","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.1016\/0735-1097(92)90373-U","article-title":"Physiologic changes with maximal exercise in asymptomatic valvular aortic stenosis assessed by Doppler echocardiography","volume":"20","author":"Otto","year":"1992","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib33","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/S0894-7317(96)90143-1","article-title":"Flow dependence of the aortic valve area in patients with aortic stenosis","volume":"9","author":"Rask","year":"1996","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1016\/j.jacc.2005.05.100_bib34","doi-asserted-by":"crossref","first-page":"1294","DOI":"10.1016\/S0735-1097(87)80469-2","article-title":"When should Doppler-determined valve area be better than the Gorlin formula? Variation in hydraulic constants in low flow states","volume":"9","author":"Segal","year":"1987","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib35","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1016\/S0735-1097(97)00532-9","article-title":"Flow dependence of valve area in aortic stenosis","volume":"31","author":"Shively","year":"1998","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib36","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1093\/oxfordjournals.eurheartj.a059740","article-title":"Normal and stenotic human aortic valve opening","volume":"11","author":"Montarello","year":"1990","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jacc.2005.05.100_bib37","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1016\/j.echo.2004.03.030","article-title":"Estimation of aortic valve effective orifice area by Doppler echocardiography","volume":"17","author":"Garcia","year":"2004","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1016\/j.jacc.2005.05.100_bib38","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1053\/euje.1999.0005","article-title":"Utility of the proximal jet width in the assessment of regurgitant and stenotic orifices\u2014effect of low velocity filter and comparison to actual vena contracta width","volume":"1","author":"DeGroff","year":"2000","journal-title":"Eur J Echocardiogr"},{"key":"10.1016\/j.jacc.2005.05.100_bib39","doi-asserted-by":"crossref","first-page":"1953","DOI":"10.1161\/01.CIR.101.16.1953","article-title":"A method for determining the reference effective flow areas for mechanical heart valve prostheses in vitro validation studies","volume":"101","author":"Shandas","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2005.05.100_bib40","doi-asserted-by":"crossref","first-page":"1931","DOI":"10.1016\/S0735-1097(98)00460-4","article-title":"Variation of anatomic valve area during ejection in patients with valvular aortic stenosis evaluated by two-dimensional echocardiographic planimetry","volume":"32","author":"Arsenault","year":"1998","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib41","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1016\/S0002-9149(99)00820-6","article-title":"Flow dynamics of stenotic aortic valves assessed by signal processing of Doppler spectrograms","volume":"85","author":"Bermejo","year":"2000","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib42","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1016\/S0894-7317(03)00472-3","article-title":"Temporal variations in effective orifice area during ejection in patients with valvular aortic stenosis","volume":"16","author":"Beauchesne","year":"2003","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1016\/j.jacc.2005.05.100_bib43","first-page":"151","article-title":"Particle image velocimetry","author":"Raffel","year":"1998"},{"key":"10.1016\/j.jacc.2005.05.100_bib44","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1016\/S0021-9290(01)00132-4","article-title":"Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro","volume":"34","author":"Lim","year":"2001","journal-title":"J Biomech"},{"key":"10.1016\/j.jacc.2005.05.100_bib45","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.1016\/S0735-1097(97)00060-0","article-title":"Simultaneous determination of aortic valve area by the Gorlin formula and by transesophageal echocardiography under different transvalvular flow conditions. Evidence that anatomic aortic valve area does not change with variations in flow in aortic stenosis","volume":"29","author":"Tardif","year":"1997","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib46","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/S0002-9149(99)80061-7","article-title":"Effects of variations in flow on aortic valve area in aortic stenosis based on in vivo planimetry of aortic valve area by multiplane transesophageal echocardiography","volume":"76","author":"Tardif","year":"1995","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacc.2005.05.100_bib47","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1016\/S0021-9290(02)00448-7","article-title":"A computational fluid-structure interaction analysis of a fiber-reinforced stentless aortic valve","volume":"36","author":"De","year":"2003","journal-title":"J Biomech"}],"container-title":["Journal of the American College of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0735109705023582?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0735109705023582?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,4,10]],"date-time":"2019-04-10T02:27:15Z","timestamp":1554863235000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0735109705023582"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,1]]},"references-count":47,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2006,1]]}},"alternative-id":["S0735109705023582"],"URL":"https:\/\/doi.org\/10.1016\/j.jacc.2005.05.100","relation":{},"ISSN":["0735-1097"],"issn-type":[{"value":"0735-1097","type":"print"}],"subject":[],"published":{"date-parts":[[2006,1]]}}}