{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T10:42:33Z","timestamp":1790419353224,"version":"4.1.0"},"reference-count":50,"publisher":"Elsevier BV","issue":"14","license":[{"start":{"date-parts":[[2008,4,1]],"date-time":"2008-04-01T00:00:00Z","timestamp":1207008000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2013,8,22]],"date-time":"2013-08-22T00:00:00Z","timestamp":1377129600000},"content-version":"vor","delay-in-days":1969,"URL":"https:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of the American College of Cardiology"],"published-print":{"date-parts":[[2008,4]]},"DOI":"10.1016\/j.jacc.2007.09.073","type":"journal-article","created":{"date-parts":[[2008,4,1]],"date-time":"2008-04-01T08:12:40Z","timestamp":1207037560000},"page":"1357-1365","source":"Crossref","is-referenced-by-count":657,"title":["Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II"],"prefix":"10.1016","volume":"51","author":[{"given":"James P.","family":"Daubert","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wojciech","family":"Zareba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David S.","family":"Cannom","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott","family":"McNitt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Spencer Z.","family":"Rosero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudio","family":"Schuger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan S.","family":"Steinberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven L.","family":"Higgins","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David J.","family":"Wilber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helmut","family":"Klein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark L.","family":"Andrews","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W. Jackson","family":"Hall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arthur J.","family":"Moss","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacc.2007.09.073_bib1","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.1056\/NEJM199711273372202","article-title":"A Comparison of Antiarrhythmic-Drug Therapy with Implantable Defibrillators in Patients Resuscitated from Near-Fatal Ventricular Arrhythmias","volume":"337","year":"1997","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jacc.2007.09.073_bib2","doi-asserted-by":"crossref","first-page":"1882","DOI":"10.1056\/NEJM199912163412503","article-title":"A randomized study of the prevention of sudden death in patients with coronary artery disease","volume":"341","author":"Buxton","year":"1999","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jacc.2007.09.073_bib3","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1056\/NEJMoa013474","article-title":"Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction","volume":"348","author":"Moss","year":"2002","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jacc.2007.09.073_bib4","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1056\/NEJMoa043399","article-title":"Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure","volume":"352","author":"Bardy","year":"2005","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jacc.2007.09.073_bib5","doi-asserted-by":"crossref","first-page":"2151","DOI":"10.1056\/NEJMoa033088","article-title":"Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy","volume":"350","author":"Kadish","year":"2004","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jacc.2007.09.073_bib6","doi-asserted-by":"crossref","first-page":"1880","DOI":"10.1161\/01.CIR.87.6.1880","article-title":"Shock occurrence and survival in 241 patients with implantable cardioverter-defibrillator therapy","volume":"87","author":"Grimm","year":"1993","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2007.09.073_bib7","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1161\/01.CIR.98.7.663","article-title":"Adverse events with transvenous implantable cardioverter-defibrillators: a prospective multicenter study","volume":"98","author":"Rosenqvist","year":"1998","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2007.09.073_bib8","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1023\/B:CEPR.0000023163.67758.b1","article-title":"Clinical significance of device-related complications in clinical trials and implications for future trials: insights from the Antiarrhythmics Versus Implantable Defibrillators (AVID) trial","volume":"7","author":"Kron","year":"2003","journal-title":"Card Electrophysiol Rev Cardiovasc Med"},{"key":"10.1016\/j.jacc.2007.09.073_bib9","doi-asserted-by":"crossref","first-page":"1322","DOI":"10.1111\/j.1540-8159.2005.00275.x","article-title":"Advanced ICD troubleshooting: part I","volume":"28","author":"Swerdlow","year":"2005","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib10","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1111\/j.1540-8159.1997.tb04844.x","article-title":"Complications associated with pectoral implantation of cardioverter defibrillators","volume":"20","author":"Gold","year":"1997","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib11","doi-asserted-by":"crossref","first-page":"1517","DOI":"10.1161\/01.CIR.98.15.1517","article-title":"Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads","volume":"98","author":"Epstein","year":"1998","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2007.09.073_bib12","doi-asserted-by":"crossref","first-page":"1482","DOI":"10.1161\/01.CIR.81.5.1482","article-title":"Automatic implantable cardioverter\/defibrillator discharges and acute myocardial injury","volume":"81","author":"Avitall","year":"1990","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2007.09.073_bib13","first-page":"71","article-title":"Psychological ramifications of surviving sudden cardiac death","volume":"1","author":"Finkelmeier","year":"1984","journal-title":"Crit Care Q"},{"key":"10.1016\/j.jacc.2007.09.073_bib14","doi-asserted-by":"crossref","first-page":"1815","DOI":"10.1111\/j.1540-8159.1993.tb01816.x","article-title":"Patient acceptance of the implantable cardioverter defibrillator in ventricular tachyarrhythmias","volume":"16","author":"Luderitz","year":"1993","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib15","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1161\/hc0502.103330","article-title":"Quality of Life in the Antiarrhythmics Versus Implantable Defibrillators Trial","volume":"105","author":"Schron","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2007.09.073_bib16","doi-asserted-by":"crossref","first-page":"144","DOI":"10.4037\/ajcc2003.12.2.144","article-title":"Phantom shock in a patient with an implantable cardioverter defibrillator: case report","volume":"12","author":"Prudente","year":"2003","journal-title":"Am J Crit Care"},{"key":"10.1016\/j.jacc.2007.09.073_bib17","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1111\/j.1540-8167.1992.tb00983.x","article-title":"Incidence of atrial fibrillation following ventricular defibrillation with transvenous lead systems in man","volume":"3","author":"Jones","year":"1992","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib18","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.hrthm.2004.11.019","article-title":"Inappropriate therapy and fatal proarrhythmia by an implantable cardioverter-defibrillator","volume":"2","author":"Vollmann","year":"2005","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacc.2007.09.073_bib19","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1046\/j.1540-8167.2003.01554.x","article-title":"Analysis of implantable cardioverter defibrillator therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) trial","volume":"14","author":"Klein","year":"2003","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib20","doi-asserted-by":"crossref","first-page":"2898","DOI":"10.1161\/CIRCULATIONAHA.104.526673","article-title":"Appropriate and inappropriate ventricular therapies, quality of life, and mortality among primary and secondary prevention implantable cardioverter defibrillator patients: results from the Pacing Fast VT REduces Shock ThErapies (PainFREE Rx II) trial","volume":"111","author":"Sweeney","year":"2005","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2007.09.073_bib21","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1111\/j.1540-8167.1995.tb00385.x","article-title":"Stability: an ICD detection criterion for discriminating atrial fibrillation from ventricular tachycardia","volume":"6","author":"Higgins","year":"1995","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib22","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1111\/j.1540-8167.1999.tb01261.x","article-title":"Clinical experience with the new detection algorithms for atrial fibrillation of a defibrillator with dual chamber sensing and pacing","volume":"10","author":"Kuhlkamp","year":"1999","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib23","doi-asserted-by":"crossref","first-page":"3760","DOI":"10.1161\/01.CIR.0000150390.04704.B7","article-title":"Long-term clinical course of patients after termination of ventricular tachyarrhythmia by an implanted defibrillator","volume":"110","author":"Moss","year":"2004","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2007.09.073_bib24","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1046\/j.1540-8167.2001.00606.x","article-title":"Supraventricular tachycardia\u2013ventricular tachycardia discrimination algorithms in implantable cardioverter defibrillators: state-of-the-art review","volume":"12","author":"Swerdlow","year":"2001","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib25","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1046\/j.1540-8167.2004.03625.x","article-title":"Differences in tachyarrhythmia detection and implantable cardioverter defibrillator therapy by primary or secondary prevention indication in cardiac resynchronization therapy patients","volume":"15","author":"Wilkoff","year":"2004","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib26","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/j.amjcard.2004.09.017","article-title":"Clinical variables predicting inappropriate use of implantable cardioverter-defibrillator in patients with coronary heart disease or nonischemic dilated cardiomyopathy","volume":"95","author":"Theuns","year":"2005","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib27","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1111\/j.1540-8159.2005.00195.x","article-title":"Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients","volume":"28","author":"Alter","year":"2005","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib28","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1111\/j.1540-8167.2006.00526.x","article-title":"Cigarette smoking and the risk of supraventricular and ventricular tachyarrhythmias in high-risk cardiac patients with implantable cardioverter defibrillators","volume":"17","author":"Goldenberg","year":"2006","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib29","doi-asserted-by":"crossref","first-page":"1418","DOI":"10.1016\/0735-1097(91)90566-R","article-title":"Arrhythmias induced by device antitachycardia therapy due to diagnostic nonspecificity","volume":"18","author":"Johnson","year":"1991","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib30","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1016\/S0002-9149(97)00556-0","article-title":"Induction of atrial fibrillation with low-energy defibrillator shocks in patients with implantable cardioverter defibrillators","volume":"80","author":"Florin","year":"1997","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib31","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1016\/0735-1097(94)90298-4","article-title":"Underdetection of ventricular tachycardia by algorithm to enhance specificity in a tiered therapy cardioverter defibrillator","volume":"24","author":"Swerdlow","year":"1994","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib32","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1046\/j.1540-8167.2005.40643.x","article-title":"Optimal combination of discriminators for differentiating ventricular from supraventricular tachycardia by dual-chamber defibrillators","volume":"16","author":"Glikson","year":"2005","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib33","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1161\/01.CIR.0000140259.16185.7D","article-title":"The 1+1 Trial: a prospective trial of a dual- versus a single-chamber implantable defibrillator in patients with slow ventricular tachycardias","volume":"110","author":"Bansch","year":"2004","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2007.09.073_bib34","doi-asserted-by":"crossref","first-page":"2882","DOI":"10.1111\/j.1540-8159.1997.tb05456.x","article-title":"Underdetection of ventricular tachycardia using a 40 ms stability criterion: effect of antiarrhythmic therapy","volume":"20","author":"LeFranc","year":"1997","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib35","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1046\/j.1540-8167.2001.00134.x","article-title":"Do current dual chamber cardioverter defibrillators have advantages over conventional single chamber cardioverter defibrillators in reducing inappropriate therapies?","volume":"12","author":"Deisenhofer","year":"2001","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib36","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1046\/j.1460-9592.2001.00835.x","article-title":"Inappropriate detection of supraventricular arrhythmias by implantable dual chamber defibrillators: a comparison of four different algorithms","volume":"24","author":"Hintringer","year":"2001","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib37","doi-asserted-by":"crossref","first-page":"2871","DOI":"10.1161\/CIRCULATIONAHA.105.594531","article-title":"Dual-chamber versus single-chamber detection enhancements for implantable defibrillator rhythm diagnosis: the Detect Supraventricular Tachycardia Study","volume":"113","author":"Friedman","year":"2006","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2007.09.073_bib38","doi-asserted-by":"crossref","first-page":"2862","DOI":"10.1161\/CIRCULATIONAHA.106.634113","article-title":"Overcoming the defects of a virtue: dual-chamber versus single-chamber detection enhancements for implantable defibrillator rhythm diagnosis: the Detect Supraventricular Tachycardia Study","volume":"113","author":"Sweeney","year":"2006","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2007.09.073_bib39","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1161\/01.CIR.103.3.381","article-title":"Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection: results and technical considerations","volume":"103","author":"Wilkoff","year":"2001","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2007.09.073_bib40","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1046\/j.1540-8167.2005.40474.x","article-title":"Atrial response to ventricular antitachycardia pacing discriminates mechanism of 1:1 atrioventricular tachycardia","volume":"16","author":"Ridley","year":"2005","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib41","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1111\/j.1540-8167.2006.00463.x","article-title":"The Rhythm ID Going Head to Head Trial (RIGHT): design of a randomized trial comparing competitive rhythm discrimination algorithms in implantable cardioverter defibrillators","volume":"17","author":"Berger","year":"2006","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib42","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1046\/j.1540-8167.2001.00145.x","article-title":"Use of correlation waveform analysis in discrimination between anterograde and retrograde atrial electrograms during ventricular tachycardia","volume":"12","author":"Saba","year":"2001","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib43","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.amjcard.2005.04.046","article-title":"Effects of beta-blockers on implantable cardioverter defibrillator therapy and survival in the patients with ischemic cardiomyopathy (from the Multicenter Automatic Defibrillator Implantation Trial-II)","volume":"96","author":"Brodine","year":"2005","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib44","doi-asserted-by":"crossref","first-page":"1855","DOI":"10.1056\/NEJM199906173402402","article-title":"Prevention of implantable-defibrillator shocks by treatment with sotalol","volume":"340","author":"Pacifico","year":"1999","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jacc.2007.09.073_bib45","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1001\/jama.295.2.165","article-title":"Optimal pharmacological therapy in cardioverter defibrillator patients I","volume":"295","author":"Connolly","year":"2006","journal-title":"JAMA"},{"key":"10.1016\/j.jacc.2007.09.073_bib46","doi-asserted-by":"crossref","first-page":"iii17","DOI":"10.1007\/s00392-006-1304-8","article-title":"The role of remote monitoring in the reduction of inappropriate implantable cardioverter defibrillator therapies","volume":"95","author":"Res","year":"2006","journal-title":"Clin Res Cardiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib47","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1111\/j.1540-8159.2004.00524.x","article-title":"Remote monitoring of implantable cardioverter defibrillators: a prospective analysis","volume":"27","author":"Schoenfeld","year":"2004","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib48","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1046\/j.1540-8167.2001.00143.x","article-title":"Inappropriate defibrillator therapies: are dual chamber devices providing a remedy?","volume":"12","author":"Lee","year":"2001","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib49","doi-asserted-by":"crossref","first-page":"1723","DOI":"10.1111\/j.1540-8159.1997.tb03548.x","article-title":"Inadequacy of qualitative implantable cardioverter defibrillator electrogram analysis to distinguish supraventricular from ventricular tachycardia due to electrogram changes during normally conducted complexes","volume":"20","author":"Hallett","year":"1997","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2007.09.073_bib50","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1093\/eurheartj\/ehl485","article-title":"Physical functioning and mental well-being in association with health outcome in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial II","volume":"28","author":"Piotrowicz","year":"2007","journal-title":"Eur Heart J"}],"container-title":["Journal of the American College of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0735109708003355?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0735109708003355?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,5,3]],"date-time":"2020-05-03T13:04:22Z","timestamp":1588511062000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0735109708003355"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,4]]},"references-count":50,"journal-issue":{"issue":"14","published-print":{"date-parts":[[2008,4]]}},"alternative-id":["S0735109708003355"],"URL":"https:\/\/doi.org\/10.1016\/j.jacc.2007.09.073","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.725272447.793502166","asserted-by":"object"},{"id-type":"doi","id":"10.3410\/f.725272447.793505070","asserted-by":"object"}]},"ISSN":["0735-1097"],"issn-type":[{"value":"0735-1097","type":"print"}],"subject":[],"published":{"date-parts":[[2008,4]]}}}