{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T18:26:13Z","timestamp":1786991173040,"version":"build-2736575974"},"reference-count":15,"publisher":"Elsevier BV","issue":"21","license":[{"start":{"date-parts":[[2009,11,1]],"date-time":"2009-11-01T00:00:00Z","timestamp":1257033600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2009,11,1]],"date-time":"2009-11-01T00:00:00Z","timestamp":1257033600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2013,8,22]],"date-time":"2013-08-22T00:00:00Z","timestamp":1377129600000},"content-version":"vor","delay-in-days":1390,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100008497","name":"Boston Scientific Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008497","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of the American College of Cardiology"],"published-print":{"date-parts":[[2009,11]]},"DOI":"10.1016\/j.jacc.2009.05.075","type":"journal-article","created":{"date-parts":[[2009,11,12]],"date-time":"2009-11-12T00:35:33Z","timestamp":1257986133000},"page":"1924-1931","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":230,"title":["Incidence and Predictors of Drug-Eluting Stent Fracture in Human Coronary Artery"],"prefix":"10.1016","volume":"54","author":[{"given":"Gaku","family":"Nakazawa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aloke V.","family":"Finn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Vorpahl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elena","family":"Ladich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Kutys","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isidora","family":"Balazs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank D.","family":"Kolodgie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renu","family":"Virmani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacc.2009.05.075_bib1","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1056\/NEJMoa035071","article-title":"Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery","volume":"349","author":"Moses","year":"2003","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jacc.2009.05.075_bib2","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1056\/NEJMoa032441","article-title":"A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease","volume":"350","author":"Stone","year":"2004","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jacc.2009.05.075_bib3","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/S0140-6736(07)60314-6","article-title":"Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study","volume":"369","author":"Daemen","year":"2007","journal-title":"Lancet"},{"key":"10.1016\/j.jacc.2009.05.075_bib4","doi-asserted-by":"crossref","first-page":"2435","DOI":"10.1161\/CIRCULATIONAHA.107.693739","article-title":"Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization","volume":"115","author":"Finn","year":"2007","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2009.05.075_bib5","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.jacc.2006.03.042","article-title":"Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk","volume":"48","author":"Joner","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2009.05.075_bib6","first-page":"380","article-title":"Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation","volume":"69","author":"Aoki","year":"2007","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jacc.2009.05.075_bib7","first-page":"387","article-title":"Stent fracture associated with drug-eluting stents: clinical characteristics and implications","volume":"69","author":"Lee","year":"2007","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jacc.2009.05.075_bib8","first-page":"614","article-title":"Stent fracture, an incidental finding or a significant marker of clinical in-stent restenosis?","volume":"71","author":"Shaikh","year":"2008","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jacc.2009.05.075_bib9","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/j.hlc.2007.06.004","article-title":"Very late stent fracture associated with a sirolimus-eluting stent","volume":"17","author":"Leong","year":"2008","journal-title":"Heart Lung Circ"},{"key":"10.1016\/j.jacc.2009.05.075_bib10","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1093\/eurheartj\/ehi542","article-title":"Sirolimus-eluting stent fracture with thrombus, visualization by optical coherence tomography","volume":"27","author":"Shite","year":"2006","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jacc.2009.05.075_bib11","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1016\/j.amjcard.2007.03.073","article-title":"Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation","volume":"100","author":"Lee","year":"2007","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacc.2009.05.075_bib12","doi-asserted-by":"crossref","first-page":"2974","DOI":"10.1161\/01.CIR.0000019071.72887.BD","article-title":"Morphological predictors of restenosis after coronary stenting in humans","volume":"105","author":"Farb","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2009.05.075_bib13","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1136\/jcp.2004.024174","article-title":"Coronary artery stents: identification and evaluation","volume":"58","author":"Butany","year":"2005","journal-title":"J Clin Pathol"},{"key":"10.1016\/j.jacc.2009.05.075_bib14","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.ijcard.2007.10.059","article-title":"Clinical characteristics of stent fracture after sirolimus-eluting stent implantation","volume":"131","author":"Yang","year":"2009","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.jacc.2009.05.075_bib15","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.ijcard.2007.12.067","article-title":"Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation","volume":"133","author":"Umeda","year":"2009","journal-title":"Int J Cardiol"}],"container-title":["Journal of the American College of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0735109709028460?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0735109709028460?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T12:34:33Z","timestamp":1760013273000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0735109709028460"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,11]]},"references-count":15,"journal-issue":{"issue":"21","published-print":{"date-parts":[[2009,11]]}},"alternative-id":["S0735109709028460"],"URL":"https:\/\/doi.org\/10.1016\/j.jacc.2009.05.075","relation":{},"ISSN":["0735-1097"],"issn-type":[{"value":"0735-1097","type":"print"}],"subject":[],"published":{"date-parts":[[2009,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Incidence and Predictors of Drug-Eluting Stent Fracture in Human Coronary Artery","name":"articletitle","label":"Article Title"},{"value":"Journal of the American College of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jacc.2009.05.075","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"https:\/\/doi.org\/10.1016\/j.jacc.2009.07.035","name":"associatedlink","label":"CrossRef DOI link to the associated document"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2009 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}