{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T07:29:25Z","timestamp":1777620565278,"version":"3.51.4"},"reference-count":27,"publisher":"Elsevier BV","issue":"11","license":[{"start":{"date-parts":[[2012,9,1]],"date-time":"2012-09-01T00:00:00Z","timestamp":1346457600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2012,9,1]],"date-time":"2012-09-01T00:00:00Z","timestamp":1346457600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2013,9,11]],"date-time":"2013-09-11T00:00:00Z","timestamp":1378857600000},"content-version":"vor","delay-in-days":375,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100008497","name":"Boston Scientific Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008497","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of the American College of Cardiology"],"published-print":{"date-parts":[[2012,9]]},"DOI":"10.1016\/j.jacc.2012.05.014","type":"journal-article","created":{"date-parts":[[2012,8,1]],"date-time":"2012-08-01T17:02:40Z","timestamp":1343840560000},"page":"981-987","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":63,"title":["Clinical Evaluation of Defibrillation Testing in an Unselected Population of 2,120 Consecutive Patients Undergoing First Implantable Cardioverter-Defibrillator Implant"],"prefix":"10.1016","volume":"60","author":[{"given":"Michele","family":"Brignole","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eraldo","family":"Occhetta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria Grazia","family":"Bongiorni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alessandro","family":"Proclemer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefano","family":"Favale","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saverio","family":"Iacopino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leonardo","family":"Cal\u00f2","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonello","family":"Vado","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gianfranco","family":"Buja","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giosu\u00e8","family":"Mascioli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fabio","family":"Quartieri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Massimo","family":"Tritto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Umberto","family":"Parravicini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonio","family":"Castro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Corrado","family":"Tomasi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanni Quinto","family":"Villani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matteo Giuseppe","family":"D'Acri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Catherine","family":"Klersy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maurizio","family":"Gasparini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacc.2012.05.014_bib1","doi-asserted-by":"crossref","first-page":"2043","DOI":"10.1161\/01.CIR.0000015508.59749.F5","article-title":"Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the Low Energy Safety Study (LESS)","volume":"105","author":"Gold","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2012.05.014_bib2","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/j.hrthm.2005.01.015","article-title":"Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter-defibrillator insertion?","volume":"2","author":"Russo","year":"2005","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacc.2012.05.014_bib3","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.jacc.2008.04.051","article-title":"No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial)","volume":"52","author":"Blatt","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib4","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1093\/europace\/eum083","article-title":"Defibrillation testing at the time of implantation of cardioverter defibrillator in the clinical practice: a nation-wide survey","volume":"9","author":"Brignole","year":"2007","journal-title":"Europace"},{"key":"10.1016\/j.jacc.2012.05.014_bib5","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.hrthm.2007.11.018","article-title":"Complications associated with defibrillation threshold testing: the Canadian experience","volume":"5","author":"Birnie","year":"2008","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacc.2012.05.014_bib6","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1111\/j.1540-8167.2010.01850.x","article-title":"Defibrillation testing at the time of ICD insertion: an analysis from the Ontario","volume":"21","author":"Healey","year":"2010","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib7","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.1111\/j.1540-8159.1993.tb01728.x","article-title":"Standardized reporting of ICD patient outcome: the report of a North American Society of Pacing and Electrophysiology Policy Conference","volume":"16","author":"Kim","year":"1993","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib8","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/0735-1097(95)00482-3","article-title":"Classification of death in antiarrhythmia trials","volume":"27","author":"Epstein","year":"1996","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib9","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1111\/j.1540-8167.2005.00294.x","article-title":"Intraoperative testing of the implantable cardioverter-defibrillator: how much is enough?","volume":"17","author":"Pires","year":"2006","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib10","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1016\/S0735-1097(02)01784-9","article-title":"Sudden death in patients with implantable cardioverter defibrillators: the importance of post-shock electromechanical dissociation","volume":"39","author":"Mitchell","year":"2002","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib11","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1007\/s00399-006-0501-5","article-title":"Analysis of the cause of death of ICD patients during long-term follow-up","volume":"17","author":"Fiek","year":"2006","journal-title":"Herzschrittmacherther Elektrophysiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib12","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1056\/NEJMoa043399","article-title":"Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure","volume":"352","author":"Bardy","year":"2005","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jacc.2012.05.014_bib13","doi-asserted-by":"crossref","first-page":"2359","DOI":"10.1161\/CIRCULATIONAHA.110.960633","article-title":"Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study","volume":"122","author":"Saxon","year":"2010","journal-title":"Circulation"},{"issue":"Suppl","key":"10.1016\/j.jacc.2012.05.014_bib14","first-page":"143","article-title":"Comparison of ICD implantations in the United States versus Italy","volume":"30","author":"Greenberg","year":"2007","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib15","first-page":"463","article-title":"Comparison of outcomes in patients undergoing defibrillation threshold testing at the time of implantable cardioverter-defibrillator implantation versus no defibrillation threshold testing","volume":"14","author":"Hall","year":"2007","journal-title":"Cardiol J"},{"key":"10.1016\/j.jacc.2012.05.014_bib16","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1111\/j.1540-8159.2009.02329.x","article-title":"Primary prevention implantation of cardioverter defibrillator without defibrillation threshold testing: 2-year follow-up","volume":"32","author":"Bianchi","year":"2009","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib17","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1093\/europace\/euq519","article-title":"Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation","volume":"13","author":"Michowitz","year":"2011","journal-title":"Europace"},{"key":"10.1016\/j.jacc.2012.05.014_bib18","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.jacc.2008.04.051","article-title":"No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial)","volume":"52","author":"Blatt","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib20","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1016\/j.jacc.2008.05.016","article-title":"Defibrillation threshold testing in implantable cardioverter defibrillators: might less be more than enough?","volume":"52","author":"Curtis","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib21","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.jacc.2003.11.068","article-title":"Is defibrillation testing required for defibrillator implantation?","volume":"44","author":"Strickberger","year":"2004","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib22","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1093\/europace\/eur109","article-title":"Defibrillation testing at the time of implantable cardioverter defibrillator implantation: results of the European Heart Rhythm Association survey","volume":"13","author":"Morgan","year":"2011","journal-title":"Europace"},{"key":"10.1016\/j.jacc.2012.05.014_bib23","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1111\/j.1540-8159.2009.02328.x","article-title":"Defibrillation threshold testing: tradition or necessity?","volume":"32","author":"Kolb","year":"2009","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib24","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1111\/j.1540-8159.2009.02327.x","article-title":"Defibrillation testing at ICD implantation: are we asking the wrong question?","volume":"32","author":"Gold","year":"2009","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib25","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1111\/j.1540-8159.2009.02326.x","article-title":"Defibrillation threshold testing in the 21st century: necessary or not?","volume":"32","author":"Vlay","year":"2009","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib26","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1111\/j.1540-8167.2007.01095.x","article-title":"Is defibrillation testing still necessary?","volume":"19","author":"Gula","year":"2008","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib27","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1097\/HCO.0b013e32834dc366","article-title":"The values of defibrillation testing at implantable cardioverter defibrillator implantation: \u201cand then there were none.\u201d","volume":"27","author":"Gasparini","year":"2012","journal-title":"Curr Opin Cardiol"},{"key":"10.1016\/j.jacc.2012.05.014_bib28","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1111\/j.1540-8167.2005.00247.x","article-title":"Delayed defibrillation testing in patients implanted with biventricular ICD (CRT-D): a reliable and safe approach","volume":"16","author":"Gasparini","year":"2005","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["Journal of the American College of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0735109712020128?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0735109712020128?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T12:53:21Z","timestamp":1760014401000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0735109712020128"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,9]]},"references-count":27,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2012,9]]}},"alternative-id":["S0735109712020128"],"URL":"https:\/\/doi.org\/10.1016\/j.jacc.2012.05.014","relation":{},"ISSN":["0735-1097"],"issn-type":[{"value":"0735-1097","type":"print"}],"subject":[],"published":{"date-parts":[[2012,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Clinical Evaluation of Defibrillation Testing in an Unselected Population of 2,120 Consecutive Patients Undergoing First Implantable Cardioverter-Defibrillator Implant","name":"articletitle","label":"Article Title"},{"value":"Journal of the American College of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jacc.2012.05.014","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}