{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T13:05:54Z","timestamp":1762866354223,"version":"build-2065373602"},"reference-count":25,"publisher":"Elsevier BV","issue":"17","license":[{"start":{"date-parts":[[2014,5,1]],"date-time":"2014-05-01T00:00:00Z","timestamp":1398902400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,5,1]],"date-time":"2014-05-01T00:00:00Z","timestamp":1398902400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2015,5,6]],"date-time":"2015-05-06T00:00:00Z","timestamp":1430870400000},"content-version":"vor","delay-in-days":370,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100007497","name":"Biosense Webster Inc.","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/100004313","name":"General Electric","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100004313","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of the American College of Cardiology"],"published-print":{"date-parts":[[2014,5]]},"DOI":"10.1016\/j.jacc.2013.12.040","type":"journal-article","created":{"date-parts":[[2014,2,26]],"date-time":"2014-02-26T20:32:07Z","timestamp":1393446727000},"page":"1769-1775","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":30,"title":["Safety of Computed Tomography in Patients With Cardiac Rhythm Management Devices"],"prefix":"10.1016","volume":"63","author":[{"given":"Ayman A.","family":"Hussein","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ameer","family":"Abutaleb","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean","family":"Jeudy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timothy","family":"Phelan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronak","family":"Patel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Melsjan","family":"Shkullaku","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Faisal","family":"Siddiqi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vincent","family":"See","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anastasios","family":"Saliaris","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephen R.","family":"Shorofsky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timm","family":"Dickfeld","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacc.2013.12.040_bib1","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1148\/radiol.2433060993","article-title":"Effects of CT irradiation on implantable cardiac rhythm management devices","volume":"243","author":"McCollough","year":"2007","journal-title":"Radiology"},{"journal-title":"FDA public health notifications","article-title":"FDA Preliminary Public Health Notification. Possible\u00a0Malfunction of Electronic Medical Devices Caused by Computed\u00a0Tomography (CT) Scanning","year":"2008","key":"10.1016\/j.jacc.2013.12.040_bib2"},{"key":"10.1016\/j.jacc.2013.12.040_bib3","first-page":"136","article-title":"CT scans can affect the operation of implanted electronic devices","volume":"36","year":"2007","journal-title":"Health Devices"},{"key":"10.1016\/j.jacc.2013.12.040_bib4","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1253\/circj.70.190","article-title":"Does high-power computed tomography scanning equipment affect the operation of pacemakers?","volume":"70","author":"Yamaji","year":"2006","journal-title":"Circ J"},{"key":"10.1016\/j.jacc.2013.12.040_bib5","article-title":"Letter to the U.S. Food and Drug Administration (FDA),\u00a0Center for Devices and Radiological Health","author":"White","year":"2008","journal-title":"American Association of Physicists in Medicine Web site"},{"journal-title":"Office of the Inspector General Web site","article-title":"Growth in Advanced Imaging Paid Under the Medicare Physician Fee Schedule","year":"2009","key":"10.1016\/j.jacc.2013.12.040_bib6"},{"key":"10.1016\/j.jacc.2013.12.040_bib7","first-page":"789","article-title":"Why all the focus on cardiac imaging?","volume":"3","author":"Shaw","year":"2010","journal-title":"J\u00a0Am Coll Cardiol Cardiovasc Img"},{"key":"10.1016\/j.jacc.2013.12.040_bib8","doi-asserted-by":"crossref","first-page":"1232","DOI":"10.1161\/CIRCULATIONAHA.106.647800","article-title":"Food and drug administration perspective: magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients","volume":"114","author":"Faris","year":"2006","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2013.12.040_bib9","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1111\/j.1540-8159.2005.50035.x","article-title":"Government viewpoint: U.S. Food and Drug Administration: pacemakers, ICDs and MRI","volume":"28","author":"Faris","year":"2005","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2013.12.040_bib10","doi-asserted-by":"crossref","first-page":"2878","DOI":"10.1161\/CIRCULATIONAHA.107.187256","volume":"116","author":"Levine","year":"2007","journal-title":"Circulation"},{"key":"10.1016\/j.jacc.2013.12.040_bib11","first-page":"100","article-title":"Guidelines for managing radiotherapy patients with pacemakers or ICDs","volume":"42","year":"2013","journal-title":"Health Devices"},{"key":"10.1016\/j.jacc.2013.12.040_bib12","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1097\/00044067-200407000-00007","article-title":"Electromagnetic interference in cardiac rhythm management devices","volume":"15","author":"Sweesy","year":"2004","journal-title":"AACN Clin Issues"},{"key":"10.1016\/j.jacc.2013.12.040_bib13","doi-asserted-by":"crossref","first-page":"1371","DOI":"10.1056\/NEJM199811053391905","article-title":"Interference with an implantable defibrillator by an electronic antitheft-surveillance device","volume":"339","author":"Santucci","year":"1998","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jacc.2013.12.040_bib14","doi-asserted-by":"crossref","first-page":"1235","DOI":"10.1046\/j.1460-9592.2002.01235.x","article-title":"Electronic security systems and active implantable medical devices","volume":"25","author":"Irnich","year":"2002","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2013.12.040_bib15","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1046\/j.1460-9592.2003.00088.x","article-title":"Influence of mobile magnetic resonance imaging on implanted pacemakers","volume":"26","author":"Kishi","year":"2003","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2013.12.040_bib16","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1111\/j.1540-8159.1984.tb05602.x","article-title":"The effects of nuclear magnetic resonance imagers on external and implantable pulse generators","volume":"7","author":"Fetter","year":"1984","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2013.12.040_bib17","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/0002-9149(86)90768-X","article-title":"Effect of magnetic resonance imaging on DDD pacemakers","volume":"57","author":"Erlebacher","year":"1986","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacc.2013.12.040_bib18","first-page":"133","article-title":"Electromagnetic interference with a bipolar pacemaker by an induction heating (IH) rice cooker","volume":"50","author":"Nagatomo","year":"2009","journal-title":"Int\u00a0Heart J"},{"key":"10.1016\/j.jacc.2013.12.040_bib19","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1136\/heart.86.3.246","article-title":"Electromagnetic interference in patients with implanted pacemakers or cardioverter-defibrillators","volume":"86","author":"Niehaus","year":"2001","journal-title":"Heart"},{"key":"10.1016\/j.jacc.2013.12.040_bib20","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1097\/CRD.0b013e31813e0ba9","article-title":"Effects of electromagnetic interference on implanted cardiac devices and their management","volume":"15","author":"Yerra","year":"2007","journal-title":"Cardiol Rev"},{"key":"10.1016\/j.jacc.2013.12.040_bib21","doi-asserted-by":"crossref","first-page":"805","DOI":"10.6009\/jjrt.64.805","article-title":"Effect of diagnostic X-rays on implantable cardiac pacemakers and implantable cardioverter defibrillators, and its management","volume":"64","author":"Oda","year":"2008","journal-title":"Nippon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"10.1016\/j.jacc.2013.12.040_bib22","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1111\/j.1540-8159.2010.02846.x","article-title":"X-ray radiation causes electromagnetic interference in implantable cardiac pacemakers","volume":"33","author":"Hirose","year":"2010","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2013.12.040_bib23","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1046\/j.1460-9592.2002.01496.x","article-title":"Interference in implanted cardiac devices, part II","volume":"25","author":"Pinski","year":"2002","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacc.2013.12.040_bib24","doi-asserted-by":"crossref","first-page":"2879","DOI":"10.1088\/0031-9155\/47\/16\/304","article-title":"Influence of high-energy photon beam irradiation on pacemaker operation","volume":"47","author":"Mouton","year":"2002","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.jacc.2013.12.040_bib25","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1007\/s11886-009-0075-z","article-title":"CT coronary angiography: 256-slice and 320-detector row scanners","volume":"12","author":"Hsiao","year":"2010","journal-title":"Curr Cardiol Rep"}],"container-title":["Journal of the American College of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0735109714010973?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0735109714010973?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T13:08:03Z","timestamp":1760015283000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0735109714010973"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5]]},"references-count":25,"journal-issue":{"issue":"17","published-print":{"date-parts":[[2014,5]]}},"alternative-id":["S0735109714010973"],"URL":"https:\/\/doi.org\/10.1016\/j.jacc.2013.12.040","relation":{},"ISSN":["0735-1097"],"issn-type":[{"type":"print","value":"0735-1097"}],"subject":[],"published":{"date-parts":[[2014,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Safety of Computed Tomography in Patients With Cardiac Rhythm Management Devices","name":"articletitle","label":"Article Title"},{"value":"Journal of the American College of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jacc.2013.12.040","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}